A method of imaging viscoelastic parameters with acoustic radiation force
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Acoustic radiation force has been proposed as a method of interrogating the mechanical properties of tissue. One simple approach applies a series of focused ultrasonic pulses to generate an acoustic radiation force, then processes the echoes returned from these pulses to estimate the radiation-force-induced displacement as a function of time. This process can be repeated at a number of locations to acquire data for image formation. In previous work we have formed images of tissue stiffness by depicting the maximum displacement induced at each tissue location after a finite period of insonification. While these maximum displacement images are able to differentiate materials of disparate mechanical properties, they exploit only a fraction of the information available. In this paper we show that the time-displacement curves acquired from tissue mimicking phantoms exhibit a viscoelastic response which is accurately described by the Voigt model. We describe how the viscous and elastic parameters of this model may be determined from experimental data. Finally, we show phantom images that depict not only the maximum local displacement, but also the viscous and elastic model parameters. These images offer complementary information about the target.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simplex Method for Function Minimization
Nelder, J. A., & Mead, R. (1965) · The Computer Journal · doi:10.1093/comjnl/7.4.308 · Cited by 28,905
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116 · cited 1×
“Most apply either a step (Ophir et al 1991, O’Donnell et al 1994) or sinusoidal (Lerner et al 1988, Walker et al 1993, Muthupillai et al 1995) force to the surface of the tissue, and then use ultrasound or other methods to estimate resultant displacements.”
Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics
Sarvazyan, A. P., Rudenko, O. V., Swanson, S. D., Fowlkes, J. B., & Emelianov, S. Y. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00110-0 · Cited by 1,727
Physical properties of tissue : a comprehensive reference book
Duck, F. A. (1990) · Cited by 1,675
Internal displacement and strain imaging using ultrasonic speckle tracking
O'Donnell, M., Skovoroda, A. R., Shapo, B. M., & Emelianov, S. Y. (1994) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.285465 · Cited by 699 · cited 1×
“Most apply either a step (Ophir et al 1991, O’Donnell et al 1994) or sinusoidal (Lerner et al 1988, Walker et al 1993, Muthupillai et al 1995) force to the surface of the tissue, and then use ultrasound or other methods to estimate resultant displacements.”
Phantom materials for elastography
Hall, T. J., Bilgen, M., Insana, M. F., & Krouskop, T. A. (1997) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.656639 · Cited by 516
A fundamental limit on delay estimation using partially correlated speckle signals
Walker, W. F., & Trahey, G. E. (1995) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.365243 · Cited by 479
Self-citationBiophysical Bases of Elasticity Imaging
Sarvazyan, A. P., Skovoroda, A. R., Emelianov, S. Y., Fowlkes, J. B., Pipe, J. G., Adler, R. S., Buxton, R. B., & Carson, P. L. (1995) · Acoustical Imaging · doi:10.1007/978-1-4615-1943-0_23 · Cited by 301 · cited 2×
“For example, breast tissue exhibits an elastic modulus of about 1 × 104 Pa (Sarvazyan et al 1995), making it roughly five orders of magnitude stiffer than the vitreous (Zimmerman 1980).”
Lerner, R. M., Parker, K. J., Holen, J., Gramiak, R., & Waag, R. C. (1988) · Acoustical Imaging · doi:10.1007/978-1-4613-0725-9_31 · Cited by 220
Rheology of the vitreous body. Part I: Viscoelasticity of human vitreous
Lee, B., Litt, M., & Buchsbaum, G. (1992) · Biorheology · doi:10.3233/bir-1992-295-612 · Cited by 179
Tissue hardness measurement using the radiation force of focused ultrasound
Sugimoto, T., Ueha, S., & Itoh, K. (1990) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.1990.171591 · Cited by 153
Internal deformation of a uniform elastic solid by acoustic radiation force
Walker, W. F. (1999) · The Journal of the Acoustical Society of America · doi:10.1121/1.426854 · Cited by 72
Self-citation
Cited by
Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility
Nightingale, K., Soo, M. S., Nightingale, R., & Trahey, G. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00499-9 · Cited by 1,108
Medical ultrasound: imaging of soft tissue strain and elasticity
Wells, P. N. T., & Liang, H.-D. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0054 · Cited by 538
Elastography: Imaging the elastic properties of soft tissues with ultrasound
Ophir, J., Alam, S. K., Garra, B. S., Kallel, F., Konofagou, E. E., Krouskop, T., Merritt, C. R. B., Righetti, R., Souchon, R., Srinivasan, S., et al. (2002) · Journal of Medical Ultrasonics · doi:10.1007/bf02480847 · Cited by 366
Gong, Z., & Dai, Z. (2021) · Advanced Science · doi:10.1002/advs.202002178 · Cited by 320
Focused ultrasound-mediated suppression of chemically-induced acute epileptic EEG activity
Min, B.-K., Bystritsky, A., Jung, K.-I., Fischer, K., Zhang, Y., Maeng, L.-S., In Park, S., Chung, Y.-A., Jolesz, F. A., & Yoo, S.-S. (2011) · BMC Neuroscience · doi:10.1186/1471-2202-12-23 · Cited by 274
Metadata
- Authors
- Walker, W. F., Fernandez, F. J., & Negron, L. A.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2000-05-19
- Volume
- 45
- Issue
- 6
- Pages
- 1437-1447
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1973065645
- Cited by
- 176
- References
- 13
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.