Respiratory effects in human functional magnetic resonance imaging due to bulk susceptibility changes
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Functional magnetic resonance imaging relies on detecting small changes in the signal in the presence of noise from various sources. It has been shown that periodic variations in the signal at the respiratory frequency occur in the brain and various techniques have been proposed to remove them. However, the precise mechanism by which respiration affects the fMRI signal has not yet been proven. Here, we explore the nature of respiratory signal variations and the artefacts they produce in brain images. Our results demonstrate conclusively that bulk susceptibility variations in the lungs during respiration cause variations in the static magnetic field within the brain tissue. These variations in field strength and homogeneity lead to a shift of the image and a shading of image intensity in the phase encoding direction. These artefacts, if left uncorrected, may lead to the production of spurious activations and/or decreased statistical significance of true activations in fMRI. In addition, these results suggest that respiration effects may not necessarily be well characterized as simple additive noise and that an alternative model based on the physical origins of susceptibility variations may be more appropriate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional connectivity in the motor cortex of resting human brain using echo‐planar mri
Biswal, B., Zerrin Yetkin, F., Haughton, V. M., & Hyde, J. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340409 · Cited by 9,812
Empirical Analyses of BOLD fMRI Statistics
Zarahn, E., Aguirre, G. K., & D'Esposito, M. (1997) · NeuroImage · doi:10.1006/nimg.1997.0263 · Cited by 693
Retrospective estimation and correction of physiological fluctuation in functional MRI
Hu, X., Le, T. H., Parrish, T., & Erhard, P. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340211 · Cited by 475
Empirical Analyses of BOLD fMRI Statistics
Aguirre, G. K., Zarahn, E., & D'Esposito, M. (1997) · NeuroImage · doi:10.1006/nimg.1997.0264 · Cited by 472
Reduction of physiological fluctuations in fMRI using digital filters
Biswal, B., Deyoe, E. A., & Hyde, J. S. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350114 · Cited by 302
Le, T. H., & Hu, X. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350305 · Cited by 146
Raj, D., Paley, D. P., Anderson, A. W., Kennan, R. P., & Gore, J. C. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/12/321 · Cited by 116
Self-citationk‐space detection and correction of physiological artifacts in fMRI
Wowk, B., McIntyre, M. C., & Saunders, J. K. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380625 · Cited by 79
Cited by
Brain connectivity related to working memory performance
Hampson, M., Driesen, N. R., Skudlarski, P., Gore, J. C., & Constable, R. T. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.3408-06.2006 · Cited by 853
“Physiological noise in functional connectivity studies can reduce power or yield artifactual correlations (Lowe et al., 1998; Raj et al., 2001; Birn et al., 2006; Lund et al., 2006).”
BackgroundInfluentialSelf-citationResting-state fMRI confounds and cleanup
Murphy, K., Birn, R. M., & Bandettini, P. A. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.001 · Cited by 666
“variation in the lungs leading to variations in the static magnetic field within brain tissue (Raj et al., 2001).”
Birn, R. M., Smith, M. A., Jones, T. B., & Bandettini, P. A. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.11.059 · Cited by 645
Building a Science of Individual Differences from fMRI
Dubois, J., & Adolphs, R. (2016) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2016.03.014 · Cited by 628
Methods for cleaning the BOLD fMRI signal
Caballero-Gaudes, C., & Reynolds, R. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.018 · Cited by 542
Non-white noise in fMRI: Does modelling have an impact?
Lund, T. E., Madsen, K. H., Sidaros, K., Luo, W.-L., & Nichols, T. E. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.07.005 · Cited by 414
The global signal in fMRI: Nuisance or Information?
Liu, T. T., Nalci, A., & Falahpour, M. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.02.036 · Cited by 411
Noble, S., Spann, M. N., Tokoglu, F., Shen, X., Constable, R. T., & Scheinost, D. (2017) · Cerebral Cortex · doi:10.1093/cercor/bhx230 · Cited by 377
The role of physiological noise in resting-state functional connectivity
Birn, R. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.016 · Cited by 359
Kelly, R. E., Alexopoulos, G. S., Wang, Z., Gunning, F. M., Murphy, C. F., Morimoto, S. S., Kanellopoulos, D., Jia, Z., Lim, K. O., & Hoptman, M. J. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.03.028 · Cited by 345
“…structured noise remains in the data after traditional corrections are applied, such as slice-timing correction, rigid-body motion correction, high-pass temporal filtering, and spatial smoothing (Hu et al., 1995; Grootoonk et al., 2000; Andersson et al., 2001; Raj et al., 2001; Birn et al., 2004).”
BackgroundThe current state-of-the-art of spinal cord imaging: Methods
Stroman, P. W., Wheeler-Kingshott, C., Bacon, M., Schwab, J. M., Bosma, R., Brooks, J., Cadotte, D., Carlstedt, T., Ciccarelli, O., Cohen-Adad, J., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.124 · Cited by 334
Noise contributions to the fMRI signal: An overview
Liu, T. T. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.09.008 · Cited by 275
Data Quality Influences Observed Links Between Functional Connectivity and Behavior
Siegel, J. S., Mitra, A., Laumann, T. O., Seitzman, B. A., Raichle, M., Corbetta, M., & Snyder, A. Z. (2017) · Cerebral Cortex · doi:10.1093/cercor/bhw253 · Cited by 265
Respiration‐induced B0fluctuations and their spatial distribution in the human brain at 7 Tesla
Van de Moortele, P., Pfeuffer, J., Glover, G. H., Ugurbil, K., & Hu, X. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10145 · Cited by 240
Physiological Noise in Brainstem fMRI
Brooks, J. C. W., Faull, O. K., Pattinson, K. T. S., & Jenkinson, M. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00623 · Cited by 222
“…lungs and position of the tissues surrounding them will induce a time varying (at the breathing rate) change in the main magnetic field (B0), and the effect of this is to produce a shift in the phaseencoding direction of EPI data (Frank et al., 2001; Raj et al., 2001; Windischberger et al., 2002).”
BackgroundMethodInfluentialFunctional Magnetic Resonance Imaging Methods
Chen, J. E., & Glover, G. H. (2015) · Neuropsychology Review · doi:10.1007/s11065-015-9294-9 · Cited by 212
“…( Hz): cardiac pulsatility induces tissue movement and blood inflow that may cause signal fluctuations adjacent to large brain vessels (Dagli et al. 1999); respiration engenders chest movement that can alter the magnetic susceptibility and MR signal intensity (Raj et al. 2001; Brosch et al. 2002).”
BackgroundCORSICA: correction of structured noise in fMRI by automatic identification of ICA components
Perlbarg, V., Bellec, P., Anton, J.-L., Pélégrini-Issac, M., Doyon, J., & Benali, H. (2007) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2006.09.042 · Cited by 200
“On short-TR datasets, we validate that the proposed method of noise reduction allows a substantial improvement of the signal-to-noise ratio evaluated at the cardiac and respiratory frequencies, even in the gray matter, while preserving the main fluctuations related to neural activity.”
MethodBrainstem functional magnetic resonance imaging: Disentangling signal from physiological noise
Harvey, A. K., Pattinson, K. T. S., Brooks, J. C. W., Mayhew, S. D., Jenkinson, M., & Wise, R. G. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21623 · Cited by 195
The individual functional connectome is unique and stable over months to years
Horien, C., Shen, X., Scheinost, D., & Constable, R. T. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.02.002 · Cited by 190
“One possible explanation is that these networks could be less prone, relative to networks comprised of mostly non-cortical nodes, to distortions of the data from susceptibility artifacts (Noble et al., 2017; Raj et al., 2001).”
Toward a unified framework for interpreting machine-learning models in neuroimaging
Kohoutová, L., Heo, J., Cha, S., Lee, S., Moon, T., Wager, T. D., & Woo, C.-W. (2020) · Nature Protocols · doi:10.1038/s41596-019-0289-5 · Cited by 176
EEG-Informed fMRI: A Review of Data Analysis Methods
Abreu, R., Leal, A., & Figueiredo, P. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00029 · Cited by 171
“As for respiration, the thoracic modulation within each respiratory cycle produces bulk head motion, as well as changes in B0 (Raj et al., 2001) and in the arterial CO2 partial pressure (Wise et al., 2004).”
Norris, D. G. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10390 · Cited by 171
TAPAS: An Open-Source Software Package for Translational Neuromodeling and Computational Psychiatry
Frässle, S., Aponte, E. A., Bollmann, S., Brodersen, K. H., Do, C. T., Harrison, O. K., Harrison, S. J., Heinzle, J., Iglesias, S., Kasper, L., et al. (2021) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2021.680811 · Cited by 169
“The respiratory cycle introduces confounds by distortions of the magnetic field due to the movement of the participant’s chest (89) as well as bulk susceptibility variation in the lungs (90).”
BackgroundFrequency specificity of functional connectivity in brain networks
Wu, C. W., Gu, H., Lu, H., Stein, E. A., Chen, J.-H., & Yang, Y. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.05.035 · Cited by 161
“Physiological noise, including the cardiac/respiratoryinduced signal changes and variations in respiration depth, can reduce the power in functional connectivity analysis (Birn et al., 2006; Lowe et al., 1998; Raj et al., 2001).”
BackgroundfMRI in the presence of task-correlated breathing variations
Birn, R. M., Murphy, K., Handwerker, D. A., & Bandettini, P. A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.030 · Cited by 152
Faull, O. K., & Pattinson, K. T. (2017) · eLife · doi:10.7554/elife.21749 · Cited by 110
“Physiological noise can be induced by both movement during the respiratory cycle, and bulk-susceptibility issues where the change in volume of air in the chest results in distortions of the magnetic field (Brooks et al., 2013; Glover et al., 2000; Harvey et al., 2008; Raj et al., 2001).”
Background
Metadata
- Authors
- Raj, D., Anderson, A. W., & Gore, J. C.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2001-11-14
- Volume
- 46
- Issue
- 12
- Pages
- 3331-3340
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2021260330
- Cited by
- 198
- References
- 8
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.