Beat-to-beat analysis method for magnetocardiographic recordings during interventions
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Multichannel magnetocardiography (MCG) during exercise testing has been shown to detect myocardial ischaemia in patients with coronary artery disease. Previous studies on exercise MCG have focused on one or few time intervals during the recovery period and only a fragment of the data available has been utilized. We present a method for beat-to-beat analysis and parametrization of the MCG signal. The method can be used for studying and quantifying the changes induced in the MCG by interventions. We test the method with data recorded in bicycle exercise testing in healthy volunteers and patients with coronary artery disease. Information in all cardiac cycles recorded during the recovery period of exercise MCG testing is, for the first time, utilized in the signal analysis. Exercise-induced myocardial ischaemia was detected by heart rate adjustment of change in magnetic field map orientation. In addition to the ST segment, the T wave in the MCG was also found to provide information related to myocardial ischaemia. The method of analysis efficiently utilizes the spatial and temporal properties of multichannel MCG mapping, providing a new tool for detecting and quantifying fast phenomena during interventional MCG studies. The method can also be applied to an on-line analysis of MCG data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BROCKMEIER, K., SCHMITZ, L., CHAVEZ, J. D. J. B., BURGHOFF, M., KOCH, H., ZIMMERMANN, R., & TRAHMS, L. (1997) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1997.tb01824.x · Cited by 99 · cited 2×
“The effect of stress in the MCG of healthy subjects has been studied (Brockmeier et al 1994, 1997, Takala et al 1999).”
BackgroundHänninen, H., Takala, P., Mäkijärvi, M., Montonen, J., Korhonen, P., Oikarinen, L., Nenonen, J., Katila, T., & Toivonen, L. (2000) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2000.tb00380.x · Cited by 74 · cited 5×
“Ischaemia has been shown to cause a rotation of the magnetic field distribution recorded in exercise testing (Hänninen et al 2000).”
BackgroundMethodResultInfluentialSelf-citationHailer, B., Leeuwen, P. V., Lange, S., & Wehr, M. (1999) · Journal of Electrocardiology · doi:10.1016/s0022-0736(99)90103-6 · Cited by 39 · cited 1×
“In addition, changes induced by ischaemic injury current in the MCG signal have been quantified by calculation of rotation in the magnetic field maps (MFM) (Hänninen et al 2000, Van Leeuwen et al 1999) as well as by measurement of QT time dispersion (Hailer et al 1999).”
MethodMagnetocardiography and exercise testing
Brockmeier, K., Comani, S., Erné, S. N., Di Luzio, S., Pasquarelli, A., & Romani, G. L. (1994) · Journal of Electrocardiology · doi:10.1016/s0022-0736(05)80096-2 · Cited by 24 · cited 1×
“The effect of stress in the MCG of healthy subjects has been studied (Brockmeier et al 1994, 1997, Takala et al 1999).”
Background
Cited by
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174
Lim, H. K., Kwon, H., Chung, N., Ko, Y.-G., Kim, J.-M., Kim, I.-S., & Park, Y.-K. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.10.013 · Cited by 52
Hänninen, H., Takala, P., Korhonen, P., Oikarinen, L., Mäkijärvi, M., Nenonen, J., Katila, T., & Toivonen, L. (2002) · Annals of Medicine · doi:10.1080/07853890252953518 · Cited by 49
Self-citationNenonen, J., Pesola, K., H[auml ]nninen, H., Lauerma, K., Takala, P., M[auml ]kel[auml ], T., M[auml ]kij[auml ]rvi, M., Knuuti, J., Toivonen, L., & Katila, T. (2001) · Journal of Electrocardiology · doi:10.1054/jelc.2001.28824 · Cited by 27
Self-citation
Metadata
- Authors
- Takala, P., Hänninen, H., Montonen, J., Mäkijärvi, M., Nenonen, J., Toivonen, L., & Katila, T.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2001-03-01
- Volume
- 46
- Issue
- 4
- Pages
- 975-982
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2012052121
- Cited by
- 22
- References
- 4
- FWCI
- 1.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Beat-to-beat analysis method for magnetocardiographic recordings during interventions. https://app.cochat.ai/papers/10.1088/0031-9155/46/4/305
- The paper
- Takala, P., Hänninen, H., Montonen, J., Mäkijärvi, M., Nenonen, J., Toivonen, L., & Katila, T. (2001). Beat-to-beat analysis method for magnetocardiographic recordings during interventions. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/46/4/305
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.