Organ dose conversion coefficients for external photon irradiation of male and female voxel models
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
New organ equivalent dose conversion coefficients are presented for whole body irradiation with monoenergetic photons of energies between 10 keV and 10 MeV for idealized geometries and seven adult male and female voxel models. The geometries are broad parallel photon beams in anterior-posterior, posterior-anterior, left- and right-lateral direction and a full 360 degree rotation around the body length axis. Dose differences between the different voxel models are below approximately 30% for some organs and geometries in the energy range between 60 and 200 keV, but they can be up to 100% or more in single cases, due to differences in stature and individual anatomical details. For low photon energies, the differences may amount to hundreds of per cent. Extensive comparisons of the dose conversion coefficients with respective values calculated using mathematical body models revealed various degrees of unrealistic positioning of single organs in the latter models. Examples are the kidneys, spleen and stomach that are located too superficially in the mathematical models. Over- or underestimations of several tens of per cent may, thus, occur for the mathematical models, compared to the voxel models considered. In contrast to previous assumptions, when the mathematical models have been used to establish reference organ dose conversion coefficients, it can be concluded that they do not properly represent a large population of individuals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
Conversion coefficients for use in radiological protection against external radiation.
Smith, H. G. (1997) · Cited by 901
THE INTERNATIONAL COMMISSION ON RADIATION UNITS AND MEASUREMENTS
Wambersie, A. (2004) · Journal of the ICRU · doi:10.1093/jicru/ndh019 · Cited by 869
Ws, S., Hl, F., Mr, F., & Warner, G. G. (1969) · PubMed · Cited by 627
Xu, X. G., Chao, T. C., & Bozkurt, A. (2000) · Health Physics · doi:10.1097/00004032-200005000-00003 · Cited by 364
The GSF family of voxel phantoms
Petoussi-Henss, N., Zankl, M., Fill, U., & Regulla, D. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/1/307 · Cited by 280
Self-citationThe adult male voxel model ”Golem" segmented from whole-body CT patient data
Zankl, M., & Wittmann, A. (2001) · Radiation and Environmental Biophysics · doi:10.1007/s004110100094 · Cited by 207
Self-citationJones, D. G. (1997) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a032072 · Cited by 105
Chao, T., Bozkurt, A., & Xu, X. G. (2001) · Health Physics · doi:10.1097/00004032-200108000-00010 · Cited by 98
DISTRIBUTION OF DOSE IN THE BODY FROM A SOURCE OF GAMMA RAYS DISTRIBUTED UNIFORMLY IN AN ORGAN
Hl, F., & Snyder, W. S. (1968) · Elsevier eBooks · doi:10.1016/b978-1-4832-8312-8.50220-4 · Cited by 68
Cited by
Christ, A., Kainz, W., Hahn, E. G., Honegger, K., Zefferer, M., Neufeld, E., Rascher, W., Janka, R., Bautz, W., Chen, J., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/n01 · Cited by 1,439
Conversion Coefficients for Radiological Protection Quantities for External Radiation Exposures
Petoussi-Henss, N., Bolch, W. E., Eckerman, K. F., Endo, A., Hertel, N., Hunt, J., Pelliccioni, M., Schlattl, H., & Zankl, M. (2010) · Annals of the ICRP · doi:10.1016/j.icrp.2011.10.001 · Cited by 721
Self-citationEffective dose: how should it be applied to medical exposures?
Martin, C. J. (2007) · The British Journal of Radiology · doi:10.1259/bjr/25922439 · Cited by 377
Xu, X. G. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/r233 · Cited by 280
MIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck
Iacono, M. I., Neufeld, E., Akinnagbe, E., Bower, K., Wolf, J., Vogiatzis Oikonomidis, I., Sharma, D., Lloyd, B., Wilm, B. J., Wyss, M., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0124126 · Cited by 273
Kramer, R., Vieira, J. W., Khoury, H. J., Lima, F. R. A., & Fuelle, D. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/10/301 · Cited by 239
Zaidi, H., & Xu, X. G. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151934 · Cited by 219
“Zankl et al. (61, 62) from the National Research Center for Environment and Health (GSF), Germany, developed a family of nine tomographic models, all from CT images: BABY, CHILD, DONNA, FRANK, GOLEM, HELGA, IRENE, LAURA, and VISIBLE MAN.”
MethodInfluentialDeak, P., van Straten, M., Shrimpton, P. C., Zankl, M., & Kalender, W. A. (2008) · European Radiology · doi:10.1007/s00330-007-0815-7 · Cited by 214
“models available in the literature [30, 31].”
Self-citationVoxel-based computational models of real human anatomy: a review
Caon, M. (2004) · Radiation and Environmental Biophysics · doi:10.1007/s00411-003-0221-8 · Cited by 213
“Voxel models have been used with Monte Carlo techniques to calculate absorbed doses to human organs and tissues irradiated with ionising radiation in radiography [18, 19, 20, 21], for radiation protection purposes [14, 22, 23, 24] and for dosimetry of procedures involving internal radioactive sources [25, 26, 27, 28,…”
BackgroundMethodHybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models
Lee, C., Lodwick, D., Hasenauer, D., Williams, J. L., Lee, C., & Bolch, W. E. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/12/001 · Cited by 184
“The stomach shape, position and size are highly variable among individuals and even in the same individual during different periods prior and after food intake and digestion (Zankl et al 2002).”
BackgroundICRP Publication 103: Recommendations of the ICRP
Charles, M. W. (2007) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncn187 · Cited by 168
DeMarco, J. J., Cagnon, C. H., Cody, D. D., Stevens, D. M., McCollough, C. H., O'Daniel, J., & McNitt-Gray, M. F. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/17/005 · Cited by 161
Kainz, W., Neufeld, E., Bolch, W. E., Graff, C. G., Kim, C. H., Kuster, N., Lloyd, B., Morrison, T., Segars, P., Yeom, Y. S., et al. (2019) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2883437 · Cited by 109
Self-citation
Metadata
- Authors
- Zankl, M., Fill, U., Petoussi-Henss, N., & Regulla, D.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2002-07-03
- Volume
- 47
- Issue
- 14
- Pages
- 2367-2385
- ISSN
- 0031-9155 (ISSN-L)
- OpenAlex
- W2045353891
- Cited by
- 162
- References
- 10
- FWCI
- 6.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.