The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
On MEG forward modelling using multipolar expansions
Open accessAbstract
Magnetoencephalography (MEG) is a non-invasive functional imaging modality based on the measurement of the external magnetic field produced by neural current sources within the brain. The reconstruction of the underlying sources is a severely ill-posed inverse problem typically tackled using either low-dimensional parametric source models, such as an equivalent current dipole (ECD), or high-dimensional minimum-norm imaging techniques. The inability of the ECD to properly represent non-focal sources and the over-smoothed solutions obtained by minimum-norm methods underline the need for an alternative approach. Multipole expansion methods have the advantages of the parametric approach while at the same time adequately describing sources with significant spatial extent and arbitrary activation patterns. In this paper we first present a comparative review of spherical harmonic and Cartesian multipole expansion methods that can be used in MEG. The equations are given for the general case of arbitrary conductors and realistic sensor configurations and also for the special cases of spherically symmetric conductors and radially oriented sensors. We then report the results of computer simulations used to investigate the ability of a first-order multipole model (dipole and quadrupole) to represent spatially extended sources, which are simulated by 2D and 3D clusters of elemental dipoles. The overall field of a cluster is analysed using singular value decomposition and compared to the unit fields of a multipole, centred in the middle of the cluster, using subspace correlation metrics. Our results demonstrate the superior utility of the multipolar source model over ECD models in providing source representations of extended regions of activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Golub, G. (2012) · doi:10.56021/9781421407944 · Cited by 34,505
(2020) · Princeton University Press eBooks · doi:10.2307/j.ctv131bv37.5 · Cited by 22,595
Methods of Theoretical Physics
Morse, P. M., Feshbach, H., & Hill, E. L. (1954) · American Journal of Physics · doi:10.1119/1.1933765 · Cited by 13,197
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem.
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,945
Multiple dipole modeling and localization from spatio-temporal MEG data
Mosher, J. C., Lewis, P. S., & Leahy, R. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141192 · Cited by 1,048
Self-citationGeselowitz, D. A. (1970) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1970.1066765 · Cited by 317
Wang, J.-Z., Williamson, S. J., & Kaufman, L. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.142641 · Cited by 299
Model Studies of the Magnetocardiogram
Grynszpan, F., & Geselowitz, D. B. (1973) · Biophysical Journal · doi:10.1016/s0006-3495(73)86034-5 · Cited by 226 · cited 17×
“Although this is not the only possible method, it is straightforward and has been widely used in MCG source localization (e.g. Katila 1983, Nenonen et al 1991).”
BackgroundMethodInfluentialMathematical dipoles are adequate to describe realistic generators of human brain activity
de Munck, J. C., van Dijk, B. W., & Spekreijse, H. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8677 · Cited by 226
Research works printed but not linked: 2
- Bronzan J B, 1982, 5, 171
- Haberkorn W, 1998, 13, 29
Cited by
Sorted by citations
Good practice for conducting and reporting MEG research
Groß, J., Baillet, S., Barnes, G. R., Henson, R. N., Hillebrand, A., Jensen, O. B., Jerbi, K., Vladimir Litvak, A., Maeß, B., Oostenveld, R., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.10.001 · Cited by 750
Self-citationA new approach to neuroimaging with magnetoencephalography
Hillebrand, A., Singh, K. D., Holliday, I. E., Furlong, P. L., & Barnes, G. R. (2005) · Human Brain Mapping · doi:10.1002/hbm.20102 · Cited by 549
Applications of the signal space separation method
Taulu, S., Simola, J., & Kajola, M. (2005) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2005.853302 · Cited by 550
Review on solving the forward problem in EEG source analysis
Hallez, H., Vanrumste, B., Grech, R., Muscat, J., Clercq, W. D., Vergult, A., D’Asseler, Y., Camilleri, K. P., Fabri, S. G., Huffel, S. V., et al. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-46 · Cited by 530
MEG: An Introduction to Methods
Hansen, P. C., Kringelbach, M. L., & Salmelin, R. (2010) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195307238.001.0001 · Cited by 425
Presentation of electromagnetic multichannel data: The signal space separation method
Taulu, S., & Kajola, M. (2005) · Journal of Applied Physics · doi:10.1063/1.1935742 · Cited by 410
Electrophysiological source imaging: A noninvasive window to brain dynamics
He, B., Sohrabpour, A., Brown, E., & Liu, Z. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-120853 · Cited by 297
Beamformer Analysis of MEG Data
Hillebrand, A., & Barnes, G. R. (2005) · International review of neurobiology · doi:10.1016/s0074-7742(05)68006-3 · Cited by 286
Talebi, N., Guo, S., & van Aken, P. A. (2017) · Nanophotonics · doi:10.1515/nanoph-2017-0017 · Cited by 146
Chowdhury, R., Lina, J., Kobayashi, E., & Grova, C. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055969 · Cited by 135
Pitfalls in the dipolar model for the neocortical EEG sources
Riera, J. J., Ogawa, T., Goto, T., Sumiyoshi, A., Nonaka, H., Evans, A., Miyakawa, H., & Kawashima, R. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00098.2011 · Cited by 98
Reconstruction of correlated brain activity with adaptive spatial filters in MEG
Quraan, M. A., & Cheyne, D. O. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.012 · Cited by 86
Localization of realistic cortical activity in MEG using current multipoles
Jerbi, K., Baillet, S., Mosher, J. C., Nolte, G., Garnero, L., & Leahy, R. M. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.02.010 · Cited by 77
Self-citationHuang, M., Edgar, J. C., Thoma, R. J., Hanlon, F. M., Moses, S. N., Lee, R. R., Paulson, K. M., Weisend, M. P., Irwin, J. G., Bustillo, J., et al. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00041-5 · Cited by 75
A probabilistic algorithm integrating source localization and noise suppression for MEG and EEG data
Zumer, J. M., Attias, H. T., Sekihara, K., & Nagarajan, S. S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.04.054 · Cited by 71
Öisjöen, F., Schneiderman, J. F., Figueras, G. A., Chukharkin, M. L., Kalabukhov, A., Hedström, A., Elam, M., & Winkler, D. (2012) · Applied Physics Letters · doi:10.1063/1.3698152 · Cited by 69
Moiseev, A., Gaspar, J. M., Schneider, J. A., & Herdman, A. T. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.05.081 · Cited by 61
Equivalence of linear approaches in bioelectromagnetic inverse solutions
Mosher, J. C., Baillet, S., & Leahy, R. M. (2004) · IEEE Statistical Signal Processing Workshop (SSP) · doi:10.1109/ssp.2003.1289402 · Cited by 58
Self-citationPractical constraints on estimation of source extent with MEG beamformers
Hillebrand, A., & Barnes, G. R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.036 · Cited by 56
Optimal design of on‐scalp electromagnetic sensor arrays for brain source localisation
Beltrachini, L., von Ellenrieder, N., Eichardt, R., & Haueisen, J. (2021) · Human Brain Mapping · doi:10.1002/hbm.25586 · Cited by 53
Localization of extended brain sources from EEG/MEG: The ExSo-MUSIC approach
Birot, G., Albera, L., Wendling, F., & Merlet, I. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.054 · Cited by 55
Mäkinen, A. J., Zetter, R., Iivanainen, J., Zevenhoven, K. C. J., Parkkonen, L. T., & Ilmoniemi, R. J. (2020) · Journal of Applied Physics · doi:10.1063/5.0016090 · Cited by 53
Chowdhury, R. A., Merlet, I., Birot, G., Kobayashi, E., Nica, A., Biraben, A., Wendling, F., Lina, J.-M., Albera, L., & Grova, C. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.08.044 · Cited by 48
Predicting performance from functional imaging data: methods matter
Sidtis, J. J., Strother, S. C., & Rottenberg, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00349-5 · Cited by 46
Dassios, G., & FOKAS, A. S. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/3/035001 · Cited by 45
On the complementarity of electroencephalography and magnetoencephalography
Dassios, G., FOKAS, A. S., & Hadjiloizi, D. A. (2007) · Inverse Problems · doi:10.1088/0266-5611/23/6/016 · Cited by 45
Electric and Magnetic Activity of the Brain in Spherical and Ellipsoidal Geometry
Dassios, G. (2009) · Lecture notes in mathematics · doi:10.1007/978-3-642-03444-2_4 · Cited by 44
FOKAS, A. S. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0309 · Cited by 40
Magnetoencephalography and its Achilles' heel
Lütkenhöner, B. (2003) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2004.01.020 · Cited by 40
Equivalence of linear approaches in bioelectromagnetic inverse solutions
Mosher, J. C., Baillet, S., & Leahy, R. M. (2003) · IEEE Statistical Signal Processing Workshop (SSP) · Cited by 38
Self-citationMagnetoencephalography in presurgical epilepsy diagnosis
Rampp, S., & Stefan, H. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.3.335 · Cited by 35
Nara, T., Oohama, J., Hashimoto, M., Takeda, T., & Ando, S. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/13/014 · Cited by 34
Harmony: EEG/MEG Linear Inverse Source Reconstruction in the Anatomical Basis of Spherical Harmonics
Petrov, Y. (2012) · PLoS ONE · doi:10.1371/journal.pone.0044439 · Cited by 28
Multiresolution imaging of MEG cortical sources using an explicit piecewise model
Cottereau, B. R., Jerbi, K., & Baillet, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.046 · Cited by 30
Self-citationPhase delays within visual cortex shape the response to steady-state visual stimulation
Cottereau, B. R., Lorenceau, J., Gramfort, A., Clerc, M., Thirion, B., & Baillet, S. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.004 · Cited by 28
Self-citationElectrophysiological Mapping and Neuroimaging
He, B., & Ding, L. (2013) · Neural Engineering · doi:10.1007/978-1-4614-5227-0_12 · Cited by 26
Electrophysiological Neuroimaging
He, B., & Lian, J. (2007) · Springer eBooks · doi:10.1007/0-306-48610-5_7 · Cited by 23
Time-Coherent Expansion of MEG/EEG Cortical Sources
Olivier David, A., & Garnero, L. (2002) · NeuroImage · doi:10.1006/nimg.2002.1269 · Cited by 23
Aung, T., Tenney, J. R., & Bagic, A. I. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2022.831546 · Cited by 23
The multipole approach for EEG forward modeling using the finite element method
Vorwerk, J., Hanrath, A., Wolters, C. H., & Grasedyck, L. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116039 · Cited by 21
An algebraic method for identification of dipoles and quadrupoles
Nara, T. (2008) · Inverse Problems · doi:10.1088/0266-5611/24/2/025010 · Cited by 20
Line-Source Modeling and Estimation With Magnetoencephalography
Yetik, İ. Ş., Nehorai, A., Muravchik, C. H., & Haueisen, J. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.844276 · Cited by 19
3D source localization of interictal spikes in epilepsy patients with MRI lesions
Ding, L., Worrell, G. A., Lagerlund, T. D., & He, B. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/16/011 · Cited by 19
Andrei Irimia, A., Swinney, K. R., & Wikswo, J. P. (2009) · Physical Review E · doi:10.1103/physreve.79.051908 · Cited by 18
MEG for Greater Sensitivity and More Precise Localization in Epilepsy
Burgess, R. C. (2020) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2020.02.004 · Cited by 17
Magnetoencephalography for localizing and characterizing the epileptic focus
Burgess, R. C. (2019) · Handbook of clinical neurology · doi:10.1016/b978-0-444-64032-1.00013-8 · Cited by 16
Identification of the combination of monopolar and dipolar sources for elliptic equations
Chung, Y.-S., & Chung, S. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/8/085006 · Cited by 16
Unified Expression of the Quasi-Static Electromagnetic Field: Demonstration With MEG and EEG Signals
Taulu, S., & Larson, E. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3009053 · Cited by 15
A Finite Element Solution of the Forward Problem in EEG for Multipolar Sources
Beltrachini, L. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2886638 · Cited by 13
Surface-Source Modeling and Estimation Using Biomagnetic Measurements
Yetik, İ. Ş., Nehorai, A., Muravchik, C. H., Haueisen, J., & Eiselt, M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.881799 · Cited by 12
Neuroelectromagnetic Source Imaging of Brain Dynamics
Ramírez, R. R., Wipf, D., & Baillet, S. (2010) · Springer optimization and its applications · doi:10.1007/978-0-387-88630-5_8 · Cited by 11
Self-citationMinimum variance beamformer weights revisited
Moiseev, A., Doesburg, S. M., GRUNAU, R. E., & Ribary, U. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.06.079 · Cited by 11
A theoretical formulation of the electrophysiological inverse problem on the sphere
Riera, J., Valdés, P., Tanabe, K., & Kawashima, R. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/7/007 · Cited by 8
Generalization of GLRT-based magnetic anomaly detection
Pepe, P., Zozor, S., Rouve, L.-L., Coulomb, J. L., Servière, C., & Muley, J. (2015) · European Signal Processing Conference (EUSIPCO) · doi:10.1109/eusipco.2015.7362720 · Cited by 11
The octapolic ellipsoidal term in magnetoencephalography
Dassios, G., Hadjiloizi, D. A., & Kariotou, F. (2009) · Journal of Mathematical Physics · doi:10.1063/1.3036183 · Cited by 10
Inverse computation for cardiac sources using single current dipole and current multipole models
Wang, Q., Ma, P., Hong, L., Tang, X.-Z., Hua, N., & Tang, F. (2009) · Chinese Physics B · doi:10.1088/1674-1056/18/12/072 · Cited by 10
Multiple sensor sequential tracking of neural activity: Algorithm and FPGA implementation
Miao, L., Zhang, J. J., Chakrabarti, C., & Papandreou‐Suppappola, A. (2010) · Asilomar Conference on Signals, Systems and Computers (ACSSC) · doi:10.1109/acssc.2010.5757537 · Cited by 9
Direct localization of multiple magnetic dipoles for surface crack detection
Nara, T., & Ando, S. (2007) · Journal of Inverse and Ill-Posed Problems · doi:10.1515/jiip.2007.022 · Cited by 8
Patient specific conductivity models : characterization of the skull bones
Papageorgakis, C. (2017) · doi:10.70675/a45ba35fz1babz40dcz81aazce55ea186e47 · Cited by 8
Cortical origin of theta error signals
Herrera, B., Sajad, A., Errington, S. P., Schall, J. D., & Riera, J. J. (2023) · Cerebral Cortex · doi:10.1093/cercor/bhad367 · Cited by 6
Algebraic reconstruction of the general-order poles of a meromorphic function
Nara, T. (2012) · Inverse Problems · doi:10.1088/0266-5611/28/2/025008 · Cited by 7
EEG/MEG forward simulation through h- and p-type finite elements
Pursiainen, S. (2008) · Journal of Physics Conference Series · doi:10.1088/1742-6596/124/1/012041 · Cited by 7
Spatial Filtering of MEG Signals for User-Specified Spherical Regions
Özkurt, T. E., Sun, M., Jia, W., & Sclabassi, R. J. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2024760 · Cited by 7
PROCESSING OF WEAK MAGNETIC MULTICHANNEL SIGNALS: THE SIGNAL SPACE SEPARATION METHOD
Taulu, S. (2008) · Aaltodoc (Aalto University) · Cited by 7
Cardiac magnetic source imaging based on current multipole model
Tang, F., Wang, Q., Hua, N., Lu, H., Tang, X.-Z., & Ma, P. (2011) · Chinese Physics B · doi:10.1088/1674-1056/20/1/010702 · Cited by 6
A Probabilistic Algorithm Integrating Source Localization and Noise Suppression of MEG and EEG Data
Zumer, J. M., Attias, H. T., Sekihara, K., & Nagarajan, S. S. (2007) · The MIT Press eBooks · doi:10.7551/mitpress/7503.003.0208 · Cited by 6
Computational methods in electromagnetic biomedical inverse problems
Pursiainen, S. (2008) · Aaltodoc (Aalto University) · Cited by 6
Tang, F., Wang, Q., Hua, N., Tang, X.-Z., Lu, H., & Ma, P. (2010) · Chinese Physics B · doi:10.1088/1674-1056/19/12/120601 · Cited by 5
Improving EEG source analysis using prior knowledge
Oostenveld, R. (2003) · Radboud Repository (Radboud University) · Cited by 5
Three-Dimensional Imaging of Complex Neural Activation in Humans From EEG
Ding, L., Zhang, N., Chen, W., & He, B. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2020438 · Cited by 4
“Theoretically, it has been proven that the lead field related to the higher order moments in multipole expansions can be derived by successive differentiation of the lead field related to the dipole moments [23], [24], which is independent of the choice of volume conductor models.”
BackgroundNeural Scales in SEEG: Biophysical Principles and Technological Advances
Mannepalli, T., Gavvala, J. R., & Mosher, J. C. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-10877-8.00011-5 · Cited by 4
Self-citationCharacterization of Brain Dynamics Using Beamformer Techniques: Advantages and Limitations
Maher, A. (2011) · InTech eBooks · doi:10.5772/28072 · Cited by 4
Identification of multipoles via boundary measurements
CHUNG, Y.-S., KIM, J. E., & Chung, S. (2011) · European Journal of Applied Mathematics · doi:10.1017/s0956792511000386 · Cited by 4
Superficial magnetic imaging by an xy-scanner of three magnetoresistive channels
Cano, M. E., Pacheco, A. H., Córdova–Fraga, T., Mazón-Valadez, E. E., & Barrera, A. (2012) · Review of Scientific Instruments · doi:10.1063/1.3694002 · Cited by 3
Gramfort, A., Cottereau, B. R., Clerc, M., Thirion, B., & Baillet, S. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353450 · Cited by 3
Self-citationAn Explicit Method for Inverse Reconstruction of Equivalent Current Dipoles and Quadrupoles
Nara, T. (2011) · InTech eBooks · doi:10.5772/30081 · Cited by 2
王倩, Ning, H., Xue-Zheng, T., 陆宏, Ma, P., & Fa-Kuan, T. (2010) · Chinese Physics B · doi:10.1088/1674-1056/19/8/080601 · Cited by 2
Reconstruction of the number and positions of dipoles and quadrupoles using an algebraic method
Nara, T. (2008) · Journal of Physics Conference Series · doi:10.1088/1742-6596/135/1/012076 · Cited by 2
Algebraic Reconstruction of Current Dipoles and Quadrupoles in Three-Dimensional Space
Nara, T. (2013) · Mathematical Problems in Engineering · doi:10.1155/2013/413980 · Cited by 2
Line-source modeling and estimation with magnetoencephalography
Yetik, İ. Ş., Nehorai, A., Muravchik, C. H., & Haueisen, J. (2005) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2004.1398794 · Cited by 2
Magnetoencephalographic Imaging
Nagarajan, S. S., & Sekihara, K. (2014) · Springer eBooks · doi:10.1007/978-3-642-33045-2_6 · Cited by 2
Multiresolution Imaging of Neural Currents from MEG Data Using an Explicit Piecewise Image Model
Cottereau, B. R., Jerbi, K., & Baillet, S. (2006) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2006.1624895 · Cited by 2
Self-citationThe magnetostatic multipole expansion in biomagnetism: applications and implications
Nurminen, J. (2014) · Aaltodoc (Aalto University) · Cited by 2
Inferring neural sources from electroencephalography: foundations and frontiers
Phillips, A. R., Vakilna, Y. S., EPMoghaddam, D., Banta, A. R., Mosher, J. C., & Aazhang, B. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae3e16 · Cited by 3
Self-citationNara, T., Koiwa, K., Takagi, S., Oyama, D., & Uehara, G. (2014) · Journal of Applied Physics · doi:10.1063/1.4869066 · Cited by 1
Direct method for reconstruction of multiple equivalent current dipoles
Nara, T., Oohama, J., Ando, S., & Takeda, T. (2007) · International Congress Series · doi:10.1016/j.ics.2006.12.080 · Cited by 1
Super-resolution for MEG Inversion -Reconstruction from the Partial Boundary Measurement
Nara, T., Oohama, J., & Ando, S. (2006) · SICE-ICASE International Joint Conference · doi:10.1109/sice.2006.314696 · Cited by 1
The unique determination of the primary current by MEG and EEG
Peng, L., Cheng, J., & Lu, J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/21/012 · Cited by 1
Öisjöen, F. (2012) · Springer theses · doi:10.1007/978-3-642-31356-1_4 · Cited by 1
Kitahara, T., & Honda, S. (2011) · Society of Instrument and Control Engineers of Japan
Magnetoencephalography based on high-Tc superconductivity: a closer look into the brain?Preprint
Öisjöen, F., Schneiderman, J. F., Figueras, G. A., Chukharkin, M. L., Kalabukhov, A., Hedström, A., Elam, M., & Winkler, D. (2011) · arXiv (Cornell University) · doi:10.48550/arxiv.1111.3241
Iterative minimum norm methods for MEG inverse problem
Kitahara, T., & Honda, S. (2012) · Society of Instrument and Control Engineers of Japan
Methodological and clinical aspects of ictal and interictal MEG
Medvedovsky, M. (2015) · Työväentutkimus Vuosikirja
Khan, S., Cottereau, B. R., Leahy, R. M., Mosher, J. C., Ammari, H. M., & Baillet, S. (2008) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2008.4541184
Self-citationDirect source reconstruction of MEG inverse problem using cerebral cortex shapes
Hashimoto, M., & Nara, T. (2008) · SICE Annual Conference (SICE) · doi:10.1109/sice.2008.4654816
Chung, Y.-S., & Chung, S. (2010) · 한국산업응용수학회 학술대회 논문집
Current dipole estimation from magnetospinogram with 3-D planar sensor array
Honda, S. (2017) · Annual Conference of the Society of Instrument and Control Engineers of Japan · doi:10.23919/sice.2017.8105691
Source characterization using linear transformations of multichannel biomagnetic recordings
Popescu, E.-A. (2008) · Νημερτής
Reconstruction of current dipoles based on tensor decomposition of multipole coefficients
Kabashima, K., Wu, T., & Nara, T. (2019) · JSIAM Letters · doi:10.14495/jsiaml.11.29
Magnetoencephalographic Imaging
Nagarajan, S. S., & Sekihara, K. (2019) · Springer eBooks · doi:10.1007/978-3-319-62657-4_6-1
Metadata
- Authors
- Jerbi, K., Mosher, J. C., Baillet, S., & Leahy, R. M.
- Affiliations
- University of Southern California (US)
- Los Alamos National Laboratory (US)
- Centre National de la Recherche Scientifique (FR)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2002-01-31
- Volume
- 47
- Issue
- 4
- Pages
- 523-555
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2008589555
- Cited by
- 103
- References
- 38
- Citations by year
- 2026: 1 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 1 · 2020: 3 · 2019: 5 · 2018: 2 · 2017: 3 · 2016: 1 · 2015: 3 · 2014: 4 · 2013: 2 · 2012: 10
- FWCI
- 2.34
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- U.S. Department of Energy (W-7405, W-7405-ENG-36)
- National Institute of Mental Health (R01-MH53213, R01MH053213)
- Los Alamos National Laboratory (W‐7405‐ENG‐36)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Physical Sciences › Computer Science › Signal Processing › Direction-of-Arrival Estimation Techniques
- Keywords
- magnetoencephalography, multipole expansion, spherical harmonics, equivalent current dipole, source localization, singular value decomposition, realistic head model
- MeSH terms
- Biophysics, Humans, Magnetics, Models, Theoretical, Magnetoencephalography, Models, Statistical, Biophysical Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review