A non-invasive method for focusing ultrasound through the human skull
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
A technique for focusing ultrasound through the human skull is described and verified. The approach is based on a layered wavevector-frequency domain model, which propagates ultrasound from a hemisphere-shaped transducer through the skull using input from CT scans of the head. The algorithm calculates the driving phase of each transducer element in order to maximize the signal at the intended focus. This approach is tested on ten ex vivo human skulls using a 0.74 MHz, 320-element array. A stereotaxic reference frame is affixed to the skulls in order to provide accurate registration between the CT images and the transducer. The focal quality is assessed with a hydrophone placed inside the skull. In each trial the phase correction algorithm successfully restored the focus inside the skull at a location within 1 mm from the intended focal point. The results demonstrate the feasibility of using the method for completely non-invasive ultrasound brain surgery and therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kinsler, L. E., Frey, A. R., & Bennett, G. S. (1951) · American Journal of Physics · doi:10.1119/1.1932798 · Cited by 3,375
Acoustics: An Introduction to Its Physical Principles and Applications
Pierce, A. D., & Saunders, H. (1984) · Journal of Vibration and Acoustics · doi:10.1115/1.3269197 · Cited by 2,235
Noninvasive MR Imaging–guided Focal Opening of the Blood-Brain Barrier in Rabbits
Hynynen, K., McDannold, N., Vykhodtseva, N., & Jolesz, F. A. (2001) · Radiology · doi:10.1148/radiol.2202001804 · Cited by 1,456
Self-citationDemonstration of Potential Noninvasive Ultrasound Brain Therapy Through an Intact Skull
Hynynen, K., & Jolesz, F. A. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00269-x · Cited by 446
Self-citation(1997) · Linear Models · doi:10.1002/9781118491782.ch1 · Cited by 379
Thomas, J.-L., & Fink, M. A. (1996) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.542055 · Cited by 312
Tanter, M., Thomas, J.-L., & Fink, M. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.422759 · Cited by 248
Focusing of therapeutic ultrasound through a human skull: A numerical study
Sun, J., & Hynynen, K. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.424383 · Cited by 213
Self-citationA hemisphere array for non-invasive ultrasound brain therapy and surgery
Clement, G. T., Sun, J., Giesecke, T., & Hynynen, K. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/12/314 · Cited by 186
Self-citationHynynen, K., & Sun, J. (1999) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.764862 · Cited by 140
Self-citationSun, J., & Hynynen, K. (1999) · The Journal of the Acoustical Society of America · doi:10.1121/1.426863 · Cited by 139
Self-citationThe role of nonlinear ultrasound propagation during hyperthermia treatments
Hynynen, K. (1991) · Medical Physics · doi:10.1118/1.596626 · Cited by 64
Self-citation
Cited by
The blood–brain barrier: Structure, regulation and drug delivery
Wu, D., Chen, Q., Chen, X., Han, F., Chen, Z., & Wang, Y. (2023) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-023-01481-w · Cited by 1,906
“Ultrasound is a technique that can noninvasively focus deep into the body using an ultrasound field.(219) They are mechanical or elastic vibrations in a medium of a frequency above the range of human hearing (18–20 kHz).”
MethodA Pilot Study of Focused Ultrasound Thalamotomy for Essential Tremor
Elias, W. J., Huss, D., Voss, T., Loomba, J., Khaled, M., Zadicario, E., Frysinger, R. C., Sperling, S. A., Wylie, S., Monteith, S. J., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1300962 · Cited by 875
Remote Excitation of Neuronal Circuits Using Low-Intensity, Low-Frequency Ultrasound
Tyler, W. J., Tufail, Y., Finsterwald, M., Tauchmann, M. L., Olson, E. J., & Majestic, C. (2008) · PLoS ONE · doi:10.1371/journal.pone.0003511 · Cited by 707
Hynynen, K., McDannold, N., Sheikov, N. A., Jolesz, F. A., & Vykhodtseva, N. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.06.046 · Cited by 679
“The frequency used is suitable for highly localized sonication through human skull as has been reported earlier ( Clement and Hynynen , 2002 ) .”
BackgroundMethodInfluentialSelf-citationMcDannold, N., Arvanitis, C. D., Vykhodtseva, N., & Livingstone, M. S. (2012) · Cancer Research · doi:10.1158/0008-5472.can-12-0128 · Cited by 588
Metadata
- Authors
- Clement, G. T., & Hynynen, K.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2002-04-05
- Volume
- 47
- Issue
- 8
- Pages
- 1219-1236
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2111589632
- Cited by
- 510
- References
- 12
- FWCI
- 9.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.