Accuracy assessment protocols for electromagnetic tracking systems
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Electromagnetic tracking systems have found increasing use in medical applications during the last few years. As with most non-trivial spatial measurement systems, the complex determination of positions and orientations from their underlying raw sensor measurements results in complicated, non-uniform error distributions over the specified measurement volume. This makes it difficult to unambiguously determine accuracy and performance assessments that allow users to judge the suitability of these systems for their particular needs. Various assessment protocols generally emphasize different measurement aspects that typically arise in clinical use. This can easily lead to inconclusive or even contradictory conclusions. We examine some of the major issues involved and discuss three useful calibration protocols. The measurement accuracy of a system can be described in terms of its 'trueness' and its 'precision'. Often, the two are strongly coupled and cannot be easily determined independently. We present a method that allows the two to be disentangled, so that the resultant trueness properly represents the systematic, non-reducible part of the measurement error, and the resultant precision (or repeatability) represents only the statistical, reducible part. Although the discussion is given largely within the context of electromagnetic tracking systems, many of the results are applicable to measurement systems in general.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Advanced Techniques in Image-Guided Brain and Spine Surgery
Germano, I. M., Adler, J. R., Barnett, G. H., Barry, C. J., Bederson, J. B., Benabid, A., Berger, M. S., Bingaman, W. E., Bucholz, R., Chang, S. D., et al. (2002) · Thieme eBooks · doi:10.1055/b-002-46954 · Cited by 58
Cited by
Electromagnetic Tracking in Medicine—A Review of Technology, Validation, and Applications
Franz, A. M., Haidegger, T., Birkfellner, W., Cleary, K., Peters, T. M., & Maier-Hein, L. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2321777 · Cited by 504
Image-guidance for surgical procedures
Peters, T. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/14/r01 · Cited by 249
A Cubic 3-Axis Magnetic Sensor Array for Wirelessly Tracking Magnet Position and Orientation
Hu, C., Li, M., Song, S., Yang, W., Zhang, R., & Meng, M. Q. H. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2035711 · Cited by 241
Wood, B. J., Zhang, H., Durrani, A., Glossop, N., Ranjan, S., Lindisch, D., Levy, E., Banovac, F., Borgert, J., Krueger, S., et al. (2005) · Journal of Vascular and Interventional Radiology · doi:10.1097/01.rvi.0000148827.62296.b4 · Cited by 227
“However, this root mean square measure of error is not an accurate reflection of overall system accuracy because it may hide underlying error distribution (2).”
BackgroundComputer-assisted navigation applied to fetal cardiac intervention
Emery, S. P., Kreutzer, J., Sherman, F. R., Fujimoto, K. L., Jaramaz, B., Nikou, C., Tobita, K., & Keller, B. B. (2007) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.145 · Cited by 15
“3 mm at a distance of 100–500 mm from sensor to detector (Figure 7) (25,31,38).”
Background
Metadata
- Authors
- Frantz, D. D., Wiles, A. D., Leis, S. E., & Kirsch, S. R.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2003-07-02
- Volume
- 48
- Issue
- 14
- Pages
- 2241-2251
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2006485654
- Cited by
- 173
- References
- 2
- FWCI
- 7.04
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.