A faster method for 3D/2D medical image registration—a simulation study
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
3D/2D patient-to-computed-tomography (CT) registration is a method to determine a transformation that maps two coordinate systems by comparing a projection image rendered from CT to a real projection image. Iterative variation of the CT's position between rendering steps finally leads to exact registration. Applications include exact patient positioning in radiation therapy, calibration of surgical robots, and pose estimation in computer-aided surgery. One of the problems associated with 3D/2D registration is the fact that finding a registration includes solving a minimization problem in six degrees of freedom (dof) in motion. This results in considerable time requirements since for each iteration step at least one volume rendering has to be computed. We show that by choosing an appropriate world coordinate system and by applying a 2D/2D registration method in each iteration step, the number of iterations can be grossly reduced from n6 to n5. Here, n is the number of discrete variations around a given coordinate. Depending on the configuration of the optimization algorithm, this reduces the total number of iterations necessary to at least 1/3 of it's original value. The method was implemented and extensively tested on simulated x-ray images of a tibia, a pelvis and a skull base. When using one projective image and a discrete full parameter space search for solving the optimization problem, average accuracy was found to be 1.0 +/- 0.6(degrees) and 4.1 +/- 1.9 (mm) for a registration in six parameters, and 1.0 +/- 0.7(degrees) and 4.2 +/- 1.6 (mm) when using the 5 + 1 dof method described in this paper. Time requirements were reduced by a factor 3.1. We conclude that this hardware-independent optimization of 3D/2D registration is a step towards increasing the acceptance of this promising method for a wide number of clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093 · cited 1×
“Surface matching methods (Hill et al 2001) also appear problematic.”
A comparison of similarity measures for use in 2-D-3-D medical image registration
Penney, G. P., Weese, J., Little, J. A., Desmedt, P., Hill, D. L. G., & hawkes, D. J. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730403 · Cited by 782
Cited by
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
“…Brunie et al. (1993), Fleute and Lavallee (1999), Wunsch and Hirzinger (1996), Yamazaki et al. (2004), Zuffi et al. (1999). c Zheng et al. (2006a). d Birkfellner et al. (2003, 2009), de Bruin et al. (2008), Byrne et al. (2004), Chen et al. (2007b), Fu and Kuduvalli (2008b,a), Gong et al. (2006),…”
BackgroundMethodInfluentialImage-guidance for surgical procedures
Peters, T. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/14/r01 · Cited by 249
Russakoff, D. B., Rohlfing, T., Mori, K., Rueckert, D., Ho, A., Adler, J. R., & Maurer, C. R. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.856749 · Cited by 142
Otake, Y., Wang, A. S., Webster Stayman, J., Uneri, A., Kleinszig, G., Vogt, S., Khanna, A. J., Gokaslan, Z. L., & Siewerdsen, J. H. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/23/8535 · Cited by 89
“Global optimization approaches have been employed in 3D–2D registration in prior work, including the exhaustive search approach as in Birkfellner et al (2003), where the objective function is evaluated at a few (3–5) grid points in each of six directions with three resolution levels selecting the…”
Methodvan der Bom, I. M. J., Klein, S., Staring, M., Homan, R., Bartels, L. W., & Pluim, J. P. W. (2011) · SPIE Proceedings · doi:10.1117/12.877655 · Cited by 55
“If we consider the 2D image data as “fixed” and the 3D volume data as “moving” (since the latter is transformed to match the former), 2D-3D registration can be formulated as a minimization problem: μ̂ = argmin μ C(μ, IF , IM ) (1) where the cost function C represents the negated similarity measure that is minimized.”
Background
Metadata
- Authors
- Birkfellner, W., Wirth, J., Burgstaller, W., Baumann, B., Staedele, H., Hammer, B., Gellrich, N. C., Jacob, A. L., Regazzoni, P., & Messmer, P.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2003-07-30
- Volume
- 48
- Issue
- 16
- Pages
- 2665-2679
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2072516467
- Cited by
- 50
- References
- 2
- FWCI
- 5.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A faster method for 3D/2D medical image registration—a simulation study. https://app.cochat.ai/papers/10.1088/0031-9155/48/16/307
- The paper
- Birkfellner, W., Wirth, J., Burgstaller, W., Baumann, B., Staedele, H., Hammer, B., Gellrich, N. C., Jacob, A. L., Regazzoni, P., & Messmer, P. (2003). A faster method for 3D/2D medical image registration—a simulation study. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/48/16/307
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.