The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Poly(vinyl alcohol) gels for use as tissue phantoms in photoacoustic mammography
Open accessAbstract
Materials for solid photoacoustic breast phantoms, based on poly(vinyl alcohol) hydrogels, are presented. Phantoms intended for use in photoacoustics must possess both optical and acoustic properties of tissue. To realize the optical properties of tissue, one approach was to optimize the number of freezing and thawing cycles of aqueous poly(vinyl alcohol) solutions, a procedure which increases the turbidity of the gel while rigidifying it. The second approach concentrated on forming a clear matrix of the rigid poly(vinyl alcohol) gel without any scattering, so that appropriate amounts of optical scatterers could be added at the time of formation, to tune the optical properties as per requirement. The relevant optical and acoustic properties of such samples were measured to be close to the average properties of human breast tissue. Tumour simulating gel samples of suitable absorption coefficient were created by adding appropriate quantities of dye at the time of formation; the samples were then cut into spheres. A breast phantom embedded with such 'tumours' was developed for studying the applicability of photoacoustics in mammography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Angiogenesis in cancer and other diseases
Carmeliet, P., & Jain, R. K. (2000) · Nature · doi:10.1038/35025220 · Cited by 9,070
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Cited by
Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
Pogue, B. W., & Patterson, M. S. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2335429 · Cited by 837
A Review of Tissue Substitutes for Ultrasound Imaging
Culjat, M. O., Goldenberg, D., Tewari, P., & Singh, R. S. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.02.012 · Cited by 659
Photoacoustic imaging and temperature measurement for photothermal cancer therapy
Shah, J., Park, S., Aglyamov, S., Larson, T., Ma, L., Sokolov, K., Johnston, K., Milner, T., & Emelianov, S. Y. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2940362 · Cited by 354
Acoustical properties of selected tissue phantom materials for ultrasound imaging
Zell, K., Sperl, J. I., Vogel, M. W., Niessner, R., & Haisch, C. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/20/n02 · Cited by 336
Tissue-mimicking phantoms for photoacoustic and ultrasonic imaging
Cook, J. R., Bouchard, R. R., & Emelianov, S. Y. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.003193 · Cited by 285
Metadata
- Authors
- Kharine, A., Manohar, S., Seeton, R., Kolkman, R. G. M., Bolt, R. A., Steenbergen, W., & Mul, F. F. M. D.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2003-01-21
- Volume
- 48
- Issue
- 3
- Pages
- 357-370
- ISSN
- 0031-9155 (ISSN-L)
- OpenAlex
- W2092471525
- Cited by
- 193
- References
- 2
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Poly(vinyl alcohol) gels for use as tissue phantoms in photoacoustic mammography. https://app.cochat.ai/papers/10.1088/0031-9155/48/3/306
- The paper
- Kharine, A., Manohar, S., Seeton, R., Kolkman, R. G. M., Bolt, R. A., Steenbergen, W., & Mul, F. F. M. D. (2003). Poly(vinyl alcohol) gels for use as tissue phantoms in photoacoustic mammography. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/48/3/306
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.