Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 399

The DOI matches its Crossref record.

Acquiring 4D thoracic CT scans using a multislice helical method

Open access
Keall, P J, Starkschall, G, Shukla, H, Forster, K M, Ortiz, V, Stevens, C W, Vedam, S S, George, R, Guerrero, T, Mohan, R·2004·Physics in Medicine and Biology

Abstract

Respiratory motion degrades anatomic position reproducibility during imaging, necessitates larger margins during radiotherapy planning and causes errors during radiation delivery. Computed tomography (CT) scans acquired synchronously with the respiratory signal can be used to reconstruct 4D CT scans, which can be employed for 4D treatment planning to explicitly account for respiratory motion. The aim of this research was to develop, test and clinically implement a method to acquire 4D thoracic CT scans using a multislice helical method. A commercial position-monitoring system used for respiratory-gated radiotherapy was interfaced with a third generation multislice scanner. 4D cardiac reconstruction methods were modified to allow 4D thoracic CT acquisition. The technique was tested on a phantom under different conditions: stationary, periodic motion and non-periodic motion. 4D CT was also implemented for a lung cancer patient with audio-visual breathing coaching. For all cases, 4D CT images were successfully acquired from eight discrete breathing phases, however, some limitations of the system in terms of respiration reproducibility and breathing period relative to scanner settings were evident. Lung mass for the 4D CT patient scan was reproducible to within 2.1% over the eight phases, though the lung volume changed by 20% between end inspiration and end expiration (870 cm3). 4D CT can be used for 4D radiotherapy, respiration-gated radiotherapy, 'slow' CT acquisition and tumour motion studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0031-9155/49/10/015

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 399

Metadata

Authors
Keall, P. J., Starkschall, G., Shukla, H., Forster, K. M., Ortiz, V, Stevens, C. W., Vedam, S. S., George, R., Guerrero, T., & Mohan, R.
Venue
Physics in Medicine and Biology
Published
2004-05-05
Volume
49
Issue
10
Pages
2053-2067
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W2083256347
Cited by
399
References
0
FWCI
37.23
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Acquiring 4D thoracic CT scans using a multislice helical method. https://app.cochat.ai/papers/10.1088/0031-9155/49/10/015
The paper
Keall, P. J., Starkschall, G., Shukla, H., Forster, K. M., Ortiz, V, Stevens, C. W., Vedam, S. S., George, R., Guerrero, T., & Mohan, R. (2004). Acquiring 4D thoracic CT scans using a multislice helical method. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/49/10/015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.