The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A method to measure the hyperelastic parameters of ex vivo breast tissue samples
Abstract
Over the past decade, there has been increasing interest in modelling soft tissue deformation. This topic has several biomedical applications ranging from medical imaging to robotic assisted telesurgery. In these applications, tissue deformation can be very large due to low tissue stiffness and lack of physical constraints. As a result, deformation modelling of such organs often requires a treatment, which reflects nonlinear behaviour. While computational techniques such as nonlinear finite element methods are well developed, the required intrinsic nonlinear mechanical parameters of soft tissues that are critical to develop reliable tissue deformation models are not well known. To address this issue, we developed a system to measure the hyperelastic parameters of small ex vivo tissue samples. This measurement technique consists of indenting an unconfined small block of tissue using a computer controlled loading system while measuring the resulting indentation force. The nonlinear tissue force-displacement response is used to calculate the hyperelastic parameters via an appropriate inversion technique. This technique is based on a nonlinear least squares formulation that uses a nonlinear finite element model as the direct problem solver. The features of the system are demonstrated with two samples of breast tissue and typical hyperelastic results are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116
Initial in vivo experience with steady‐state subzone‐based MR elastography of the human breast
Van Houten, E. E. W., Doyley, M. M., Kennedy, F. E., Weaver, J. B., & Paulsen, K. D. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10232 · Cited by 224
Cited by
Samani, A., Zubovits, J., & Plewes, D. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/6/002 · Cited by 707
Self-citationHyperelastic Energy Densities for Soft Biological Tissues: A Review
Chagnon, G., Rebouah, M., & Favier, D. (2015) · Journal of Elasticity · doi:10.1007/s10659-014-9508-z · Cited by 292
Mechanics of the normal woman's breast
Gefen, A., & Dilmoney, B. (2007) · Technology and Health Care · doi:10.3233/thc-2007-15404 · Cited by 257
Elastography imaging: the 30 year perspective
Ormachea, J., & Parker, K. J. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abca00 · Cited by 104
Koo, T. K., Cohen, J. H., & Zheng, Y. (2011) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/j.jmpt.2011.05.009 · Cited by 16
Metadata
- Authors
- Samani, A., & Plewes, D.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2004-09-04
- Volume
- 49
- Issue
- 18
- Pages
- 4395-4405
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2044223573
- Cited by
- 195
- References
- 3
- FWCI
- 3.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A method to measure the hyperelastic parameters of ex vivo breast tissue samples. https://app.cochat.ai/papers/10.1088/0031-9155/49/18/014
- The paper
- Samani, A., & Plewes, D. (2004). A method to measure the hyperelastic parameters of ex vivo breast tissue samples. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/49/18/014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.