Cited by 224Ultrasound Imaging and ElastographyAdvanced MRI Techniques and ApplicationsMRI in cancer diagnosis

Initial in vivo experience with steady‐state subzone‐based MR elastography of the human breast

Van Houten, Elijah E.W., Doyley, Marvin M., Kennedy, Francis E., Weaver, John B., Paulsen, Keith D.·2003·Journal of Magnetic Resonance Imaging

Abstract

Purpose: To describe initial in vivo experiences with a subzone‐based, steady‐state MR elastography (MRE) method. This sparse collection of in vivo results is intended to shed light on some of the strengths and weaknesses of existing clinical MRE approaches and to indicate important areas of future research. Materials and Methods: Elastic property reconstruction results are compared with data compiled from the limited existing body of published studies in breast elasticity. Mechanical parameter distributions are also investigated in terms of their implications for the nature of biological soft tissue. Additionally, a derivation of the statistical variance of the elastic parameter reconstruction is given and the resulting confidence intervals (CIs) for different parameter solutions are examined. Results: By comparison with existing estimates of the elastic properties of breast tissue, the subzone‐based, steady‐state MRE method is seen to produce reasonable estimates for the mechanical properties of in vivo tissue. Conclusion: MRE shows potential as an effective way to determine the elastic properties of breast tissue, and may be of significant clinical interest. J. Magn. Reson. Imaging 2003;17:72–85. © 2002 Wiley‐Liss, Inc.

Integrity signals

Registry

Crossref · 10.1002/jmri.10232

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The moduli of dermis and subcutaneous tissue range from 56-260 kPa and 0.12-23 kPa, respectively.

    “the modulii of the dermis and subcutaneous tissue range from 56–260 kPa and 0.12–23 kPa, respectively,165–168”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Van Houten, E. E. W., Doyley, M. M., Kennedy, F. E., Weaver, J. B., & Paulsen, K. D.
Affiliations
  • Dartmouth College (US)
  • Dartmouth–Hitchcock Medical Center (US)
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2002-12-23
Volume
17
Issue
1
Pages
72-85
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2144719117
Cited by
224
References
15
Citations by year
2026: 1 · 2025: 6 · 2024: 3 · 2023: 8 · 2022: 3 · 2021: 7 · 2020: 7 · 2019: 7 · 2018: 10 · 2017: 10 · 2016: 9 · 2015: 5 · 2014: 15 · 2013: 11 · 2012: 17
FWCI
5.37
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Magnetic Resonance Imaging (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › MRI in cancer diagnosis
Keywords
magnetic resonance elastography, breast tissue elasticity, confidence intervals, soft tissue mechanical properties, breast imaging
MeSH terms
Adipose Tissue, Algorithms, Breast, Elasticity, Female, Humans, Magnetic Resonance Imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review