The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Prediction of respiratory tumour motion for real-time image-guided radiotherapy
Open accessAbstract
Image guidance in radiotherapy and extracranial radiosurgery offers the potential for precise radiation dose delivery to a moving tumour. Recent work has demonstrated how to locate and track the position of a tumour in real-time using diagnostic x-ray imaging to find implanted radio-opaque markers. However, the delivery of a treatment plan through gating or beam tracking requires adequate consideration of treatment system latencies, including image acquisition, image processing, communication delays, control system processing, inductance within the motor, mechanical damping, etc. Furthermore, the imaging dose given over long radiosurgery procedures or multiple radiotherapy fractions may not be insignificant, which means that we must reduce the sampling rate of the imaging system. This study evaluates various predictive models for reducing tumour localization errors when a real-time tumour-tracking system targets a moving tumour at a slow imaging rate and with large system latencies. We consider 14 lung tumour cases where the peak-to-peak motion is greater than 8 mm, and compare the localization error using linear prediction, neural network prediction and Kalman filtering, against a system which uses no prediction. To evaluate prediction accuracy for use in beam tracking, we compute the root mean squared error between predicted and actual 3D motion. We found that by using prediction, root mean squared error is improved for all latencies and all imaging rates evaluated. To evaluate prediction accuracy for use in gated treatment, we present a new metric that compares a gating control signal based on predicted motion against the best possible gating control signal. We found that using prediction improves gated treatment accuracy for systems that have latencies of 200 ms or greater, and for systems that have imaging rates of 10 Hz or slower.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751
(2012) · Encyclopedia of the Sciences of Learning · doi:10.1007/978-1-4419-1428-6_5195 · Cited by 19,370
Neural networks for pattern recognition
(1994) · Choice Reviews Online · doi:10.5860/choice.31-5500 · Cited by 18,538
Neural Networks for Pattern Recognition
Bishop, C. M. (1995) · doi:10.1093/oso/9780198538493.001.0001 · Cited by 12,287
Abe, S. (2001) · Springer eBooks · doi:10.1007/978-1-4471-0285-4 · Cited by 3,721
Seppenwoolde, Y., Shirato, H., Kitamura, K., Shimizu, S., van Herk, M., Lebesque, J. V., & Miyasaka, K. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02803-1 · Cited by 1,379
Self-citationThe use of active breathing control (ABC) to reduce margin for breathing motion
Wong, J. W., Sharpe, M. B., Jaffray, D. A., Kini, V. R., Robertson, J. M., Stromberg, J. S., & Martinez, A. A. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(99)00056-5 · Cited by 912
Physical aspects of a real-time tumor-tracking system for gated radiotherapy
Shirato, H., Shimizu, S., Kunieda, T., Kitamura, K., van Herk, M., Kagei, K., Nishioka, T., Hashimoto, S., Fujita, K., Aoyama, H., et al. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00748-3 · Cited by 662
Self-citationRespiration gated radiotherapy treatment: a technical study
Kubo, H., & Hill, B. C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/007 · Cited by 636
Shirato, H., Shimizu, S., Kitamura, K., Nishioka, T., Kagei, K., Hashimoto, S., Aoyama, H., Kunieda, T., Shinohara, N., Dosaka-Akita, H., et al. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00625-8 · Cited by 464
Self-citationRespiratory gated irradiation system for heavy-ion radiotherapy
Minohara, S., Kanai, T., Endo, M., Noda, K., & Kanazawa, M. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00524-1 · Cited by 457
Image-guided Robotic Radiosurgery
Adler, J. R., Murphy, M. J., Chang, S. D., & Hancock, S. L. (1999) · Neurosurgery · doi:10.1097/00006123-199906000-00079 · Cited by 412
Robotic motion compensation for respiratory movement during radiosurgery
Schweikard, A., Glosser, G., Bodduluri, M., Murphy, M. J., & Adler, J. R. (2000) · Computer Aided Surgery · doi:10.1002/1097-0150(2000)5:4<263::aid-igs5>3.0.co;2-2 · Cited by 393
Issues in respiratory motion compensation during external-beam radiotherapy
Ozhasoglu, C., & Murphy, M. J. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)02789-4 · Cited by 356
Deep inspiration breath hold to reduce irradiated heart volume in breast cancer patients
Sixel, K. E., Aznar, M. C., & Ung, Y. C. (2001) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)01455-3 · Cited by 281
Detection of lung tumor movement in real-time tumor-tracking radiotherapy
Shimizu, S., Shirato, H., Ogura, S., Akita-Dosaka, H., Kitamura, K., Nishioka, T., Kagei, K., Nishimura, M., & Miyasaka, K. (2001) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)01641-8 · Cited by 270
Self-citationReal-time tumour-tracking radiotherapy
Shirato, H., Shimizu, S., Shimizu, T., Nishioka, T., & Miyasaka, K. (1999) · The Lancet · doi:10.1016/s0140-6736(99)00700-x · Cited by 252
Self-citationDigalakis, V., Rohlicek, J. R., & Ostendorf, M. (1993) · IEEE Transactions on Speech and Audio Processing · doi:10.1109/89.242489 · Cited by 228
Potential radiotherapy improvements with respiratory gating
Keall, P. J., Kini, V. R., Vedam, S. S., & Mohan, R. (2002) · Australasian Physics & Engineering Sciences in Medicine · doi:10.1007/bf03178368 · Cited by 162
Fiducial‐based targeting accuracy for external‐beam radiotherapy
Murphy, M. J. (2002) · Medical Physics · doi:10.1118/1.1448823 · Cited by 123
Cited by
The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)
Keall, P. J., Mageras, G. S., Balter, J. M., Emery, R. S., Forster, K. M., Jiang, S. B., Kapatoes, J. M., Low, D. A., Murphy, M. J., Murray, B. R., et al. (2006) · Medical Physics · doi:10.1118/1.2349696 · Cited by 2,327
Self-citationOverview of image-guided radiation therapy
Xing, L., Thorndyke, B., Schreibmann, E., Yang, Y., Li, T.-F., Kim, G.-Y., Luxton, G., & Koong, A. (2006) · Medical Dosimetry · doi:10.1016/j.meddos.2005.12.004 · Cited by 468
Stereotactic Body Radiation Therapy in Multiple Organ Sites
Timmerman, R. D., Kavanagh, B. D., Cho, L. C., Papiez, L., & Xing, L. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.09.7469 · Cited by 438
Birkfellner, W., Stock, M., Figl, M., Gendrin, C., Hummel, J., Dong, S., Kettenbach, J., Georg, D., & Bergmann, H. (2009) · Medical Physics · doi:10.1118/1.3157111 · Cited by 44
Predicting Respiratory Motion for Real-Time Tumour Tracking in Radiotherapy
Krilavicius, T., Zliobaite, I., Simonavicius, H., & Jaruevicius, L. (2016) · 2016 IEEE 29th International Symposium on Computer-Based Medical Systems (CBMS) · doi:10.1109/cbms.2016.52 · Cited by 15
Metadata
- Authors
- Sharp, G. C., Jiang, S. B., Shimizu, S., & Shirato, H.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2004-01-16
- Volume
- 49
- Issue
- 3
- Pages
- 425-440
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2009316899
- Cited by
- 355
- References
- 20
- FWCI
- 27.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.