Measurement of bone mineral density via light scattering
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this study we have investigated the potential of optical techniques to monitor changes in bone mineral density (BMD) via changes in scattering coefficient. For each of five bone samples, diffuse reflection and transmission coefficients were measured over the wavelength range 520-960 nm using an integrating sphere and CCD spectrometer. These were converted into optical absorption and scattering coefficients using a Monte Carlo inversion procedure. Measurements were made on samples immersed in formic acid solution for different lengths of time in order to investigate the effect of reduction in BMD on the optical properties. After full demineralization, the optical scattering coefficient fell by a factor 4. From the observed degree of fluctuation of the measurements, we estimate that BMD could be measured with an accuracy of 7% if optical scattering can be measured with an accuracy of 10%. We also report preliminary measurements of bone scattering using optical coherence tomography (OCT). An inter-side variability of 3% is obtained on dry samples with and without overlying periosteum. These results suggest that minimally invasive techniques for measuring optical scattering, such as OCT, may have a role in monitoring regional changes in BMD. This could be an important advance in our understanding of bone remodelling and its relationship to osteoarthritis. Both the integrating sphere and OCT measurements also suggest that light transport in bone is spatially anisotropic. OCT was used to assess probability of obtaining results in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simpson, C. R., Kohl, M., Essenpreis, M., & Cope, M. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/9/003 · Cited by 651
Cited by
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW
BASHKATOV, A. N., GENINA, E. A., & TUCHIN, V. V. (2011) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545811001319 · Cited by 761
Alexandrakis, G., Rannou, F. R., & Chatziioannou, A. F. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/17/021 · Cited by 465
Polarized light interaction with tissues
Tuchin, V. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.071114 · Cited by 384
“126 – 128 In bone and tooth, anisotropy is due to mineralized structures originating from HAP nanocrystals, which play an important role in hard tissue depolarization and birefringence.”
BackgroundWu, X., Jiang, Y., Rommelfanger, N. J., Yang, F., Zhou, Q., Yin, R., Liu, J., Cai, S., Ren, W., Shin, A., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00862-w · Cited by 222
“The optical properties of scalp 74–76 and skull 77–79 and brain tissue 67,80 were taken from previous reports.”
Metadata
- Authors
- Ugryumova, N., Matcher, S. J., & Attenburrow, D. P.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2004-01-16
- Volume
- 49
- Issue
- 3
- Pages
- 469-483
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2054170178
- Cited by
- 109
- References
- 1
- FWCI
- 4.28
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.