Magnetoacoustic tomography with magnetic induction (MAT-MI)
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
We report our theoretical and experimental investigations on a new imaging modality, magnetoacoustic tomography with magnetic induction (MAT-MI). In MAT-MI, the sample is located in a static magnetic field and a time-varying (micros) magnetic field. The time-varying magnetic field induces an eddy current in the sample. Consequently, the sample will emit ultrasonic waves by the Lorentz force. The ultrasonic signals are collected around the object to reconstruct images related to the electrical impedance distribution in the sample. MAT-MI combines the good contrast of electrical impedance tomography with the good spatial resolution of sonography. MAT-MI has two unique features due to the solenoid nature of the induced electrical field. Firstly, MAT-MI could provide an explicit or simple quantitative reconstruction algorithm for the electrical impedance distribution. Secondly, it promises to eliminate the shielding effects of other imaging modalities in which the current is applied directly with electrodes. In the theoretical part, we provide formulae for both the forward and inverse problems of MAT-MI and estimate the signal amplitude in biological tissues. In the experimental part, the experimental setup and methods are introduced and the signals and the image of a metal object by means of MAT-MI are presented. The promising pilot experimental results suggest the feasibility of the proposed MAT-MI approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Methods of Theoretical Physics
Morse, P. M., Feshbach, H., & Hill, E. L. (1954) · American Journal of Physics · doi:10.1119/1.1933765 · Cited by 13,197
Wang, X., Pang, Y., Ku, G., Xie, X., Stoica, G., & Wang, L. V. (2003) · Nature Biotechnology · doi:10.1038/nbt839 · Cited by 1,700 · cited 6×
“In PAT, it has been demonstrated both theoretically (Xu and Wang 2003) and experimentally ( Wang et al 2003 ) that the effect of the acoustic heterogeneity in soft tissues is negligible.”
BackgroundResultInfluentialWebb, S. (1997) · Radiography · doi:10.1016/s1078-8174(97)90040-7 · Cited by 435
Reconstructions in limited‐view thermoacoustic tomography
Xu, Y., Wang, L. V., Ambartsoumian, G., & Kuchment, P. (2004) · Medical Physics · doi:10.1118/1.1644531 · Cited by 398 · cited 1×
“Nevertheless, partial view data are sufficient to reconstruct the boundary of the sample ( Xu and Wang 2004b ).”
BackgroundSelf-citationA model of the stimulation of a nerve fiber by electromagnetic induction
Roth, B. J., & Basser, P. J. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55662 · Cited by 363 · cited 1×
“-PA Author M anuscript N IH -PA Author M anuscript N IH -PA Author M anuscript for the intracranial delivery of magnetic energy into the brain (Irwin et al 1970, Barker et al 1990, Roth and Basser 1990 , Malmivuo and Plonsey 1995, Davey and Epstein 2000, Wagner et al 2004).”
BackgroundKwon, O., Woo, E. J., Yoon, J.-R., & Seo, J. K. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.979355 · Cited by 281 · cited 2×
“If we inject currents into the medium with electrodes, as used in EIT, HEI/MAT, and MREIT (Woo et al 1994, Kwon et al 2002, Gao et al 2005) the outer layer will reduce the amount of current entering into the inner layer.”
MethodEliasmith, C. (2002) · Cited by 138
A magneto-acoustic method for the noninvasive measurement of bioelectric currents
Towe, B. C., & Islam, M. R. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.7300 · Cited by 85 · cited 2×
“The MAT-MI is similar to magnetoacoustic tomography (MAT) (Towe and Islam 1988, Islam and Towe 1988, Roth et al 1994, Roth et al 1998) or the reverse mode of Hall effect imaging (HEI) (Wen et al 1998, Wen 1999, Wen 2000) where electric stimulation instead of magnetic stimulation is employed.”
MethodMagnetic stimulation coil and circuit design
Davey, K., & Epstein, C. M. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.880101 · Cited by 83 · cited 1×
“-PA Author M anuscript N IH -PA Author M anuscript N IH -PA Author M anuscript for the intracranial delivery of magnetic energy into the brain (Irwin et al 1970, Barker et al 1990, Roth and Basser 1990 , Malmivuo and Plonsey 1995, Davey and Epstein 2000, Wagner et al 2004).”
BackgroundWagner, T., Gangitano, M., Romero, R., Théoret, H., Kobayashi, M., Anschel, D., Ives, J., Cuffin, N., Schomer, D., & Pascual-Leone, A. (2004) · Neuroscience Letters · doi:10.1016/s0304-3940(03)00861-9 · Cited by 78
Gao, N., Zhu, S. A., & He, B. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/11/016 · Cited by 53 · cited 2×
“If we inject currents into the medium with electrodes, as used in EIT, HEI/MAT, and MREIT (Woo et al 1994, Kwon et al 2002, Gao et al 2005) the outer layer will reduce the amount of current entering into the inner layer.”
MethodSelf-citationElectrophysiological Neuroimaging
He, B., & Lian, J. (2007) · Springer eBooks · doi:10.1007/0-306-48610-5_7 · Cited by 24
Self-citation
Cited by
Systems Neuroengineering: Understanding and Interacting with the Brain
Edelman, B. J., Johnson, N., Sohrabpour, A., Tong, S., Thakor, N., & He, B. (2015) · Engineering · doi:10.15302/j-eng-2015078 · Cited by 45
“Xu Y, He B. Magnetoacoustic tomography with magnetic induction (MAT-MI).”
MethodInfluentialSelf-citation
Metadata
- Authors
- Xu, Y., & He, B.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2005-10-19
- Volume
- 50
- Issue
- 21
- Pages
- 5175-5187
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1965899283
- Cited by
- 225
- References
- 12
- FWCI
- 6.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.