The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Reconstructions in limited‐view thermoacoustic tomography
Open accessAbstract
The limited‐view problem is studied for thermoacoustic tomography, which is also referred to as photoacoustic or optoacoustic tomography depending on the type of radiation for the induction of acoustic waves. We define a “detection region,” within which all points have sufficient detection views. It is explained analytically and shown numerically that the boundaries of any objects inside this region can be recovered stably. Otherwise some sharp details become blurred. One can identify in advance the parts of the boundaries that will be affected if the detection view is insufficient. If the detector scans along a circle in a two‐dimensional case, acquiring a sufficient view might require covering more than a π‐, or less than a π‐arc of the trajectory depending on the position of the object. Similar results hold in a three‐dimensional case. In order to support our theoretical conclusions, three types of reconstruction methods are utilized: a filtered backprojection (FBP) approximate inversion, which is shown to work well for limited‐view data, a local‐tomography‐type reconstruction that emphasizes sharp details (e.g., the boundaries of inclusions), and an iterative algebraic truncated conjugate gradient algorithm used in conjunction with FBP. Computations are conducted for both numerically simulated and experimental data. The reconstructions confirm our theoretical predictions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
The measured electrical properties of normal and malignant human tissues from 50 to 900 MHz
Joines, W. T., Zhang, Y., Li, C., & Jirtle, R. L. (1994) · Medical Physics · doi:10.1118/1.597312 · Cited by 763
Photoacoustic ultrasound (PAUS)—Reconstruction tomography
Kruger, R. A., Liu, P., Fang, Y. “., & Appledorn, C. R. (1995) · Medical Physics · doi:10.1118/1.597429 · Cited by 572
Time-domain reconstruction for thermoacoustic tomography in a spherical geometry
Xu, M., & Wang, L. V. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.801176 · Cited by 461
Self-citationThree-dimensional photoacoustic imaging of blood vessels in tissue
Hoelen, C. G. A., de Mul, F. F. M., Pongers, R., & Dekker, A. (1998) · Optics Letters · doi:10.1364/ol.23.000648 · Cited by 446
Delaney, A. H., & Bresler, Y. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.660997 · Cited by 304
The inversion problem and applications of the generalized radon transform
Beylkin, G. (1984) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.3160370503 · Cited by 196
Surveys on Solution Methods for Inverse Problems
COLTON, D. L., Engl, H. W., Louis, A. K., et al. (2000) · Springer eBooks · doi:10.1007/978-3-7091-6296-5 · Cited by 120
Microwave power absorption differences between normal and malignant tissue
Joines, W. T., Jirtle, R. L., Rafal, M. D., & Schaefer, D. J. (1980) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(80)90223-0 · Cited by 113
Data redundancy and reduced-scan reconstruction in reflectivity tomography
Pan, X., Zou, Y. S., & Anastasio, M. A. (2003) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.814244 · Cited by 41
Cited by
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Self-citationPhotoacoustic imaging in biomedicine
Xu, M., & Wang, L. V. (2006) · Review of Scientific Instruments · doi:10.1063/1.2195024 · Cited by 2,700
Self-citationModel-Based Learning for Accelerated, Limited-View 3-D Photoacoustic Tomography
Hauptmann, A., Lucka, F., Betcke, M., Huynh, N., Adler, J., Cox, B., Beard, P., Ourselin, S., & Arridge, S. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2820382 · Cited by 339
Metadata
- Authors
- Xu, Y., Wang, L. V., Ambartsoumian, G., & Kuchment, P.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2004-03-11
- Volume
- 31
- Issue
- 4
- Pages
- 724-733
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2141505984
- Cited by
- 398
- References
- 10
- FWCI
- 8.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reconstructions in limited‐view thermoacoustic tomography. https://app.cochat.ai/papers/10.1118/1.1644531
- The paper
- Xu, Y., Wang, L. V., Ambartsoumian, G., & Kuchment, P. (2004). Reconstructions in limited‐view thermoacoustic tomography. Medical Physics. https://doi.org/10.1118/1.1644531
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.