Hyperspectral and multispectral bioluminescence optical tomography for small animal imaging
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
For bioluminescence imaging studies in small animals, it is important to be able to accurately localize the three-dimensional (3D) distribution of the underlying bioluminescent source. The spectrum of light produced by the source that escapes the subject varies with the depth of the emission source because of the wavelength-dependence of the optical properties of tissue. Consequently, multispectral or hyperspectral data acquisition should help in the 3D localization of deep sources. In this paper, we describe a framework for fully 3D bioluminescence tomographic image acquisition and reconstruction that exploits spectral information. We describe regularized tomographic reconstruction techniques that use semi-infinite slab or FEM-based diffusion approximations of photon transport through turbid media. Singular value decomposition analysis was used for data dimensionality reduction and to illustrate the advantage of using hyperspectral rather than achromatic data. Simulation studies in an atlas-mouse geometry indicated that sub-millimeter resolution may be attainable given accurate knowledge of the optical properties of the animal. A fixed arrangement of mirrors and a single CCD camera were used for simultaneous acquisition of multispectral imaging data over most of the surface of the animal. Phantom studies conducted using this system demonstrated our ability to accurately localize deep point-like sources and show that a resolution of 1.5 to 2.2 mm for depths up to 6 mm can be achieved. We also include an in vivo study of a mouse with a brain tumour expressing firefly luciferase. Co-registration of the reconstructed 3D bioluminescent image with magnetic resonance images indicated good anatomical localization of the tumour.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Discrete Ill-Posed Problems by Means of the L-Curve
Hansen, P. C. (1992) · SIAM Review · doi:10.1137/1034115 · Cited by 3,903 · cited 1×
“Applying principal components analysis, we observed that a few principal basis functions, defining a subspace much smaller than h, carry most of the depth information.”
MethodAn Introduction to the Conjugate Gradient Method Without the Agonizing Pain
Shewchuk, J. R. (1994) · Cited by 3,178
Linear and Nonlinear Programming
Luenberger, D. G., & Ye, Y. (2008) · International Series in Operations Research & Management Science · doi:10.1007/978-0-387-74503-9 · Cited by 2,804
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530 · cited 6×
“However, in small animals, due to shorter path lengths, a large fraction of photons reaches the surface of the animal and detection of bioluminescent and fluorescent signals is possible at significantly lower cost compared to MRI and PET (Rice et al 2001, Contag and Ross 2002).”
BackgroundMethodInfluentialOptical tomography in medical imaging
Arridge, S. R. (1999) · Inverse Problems · doi:10.1088/0266-5611/15/2/022 · Cited by 2,524
An overlap invariant entropy measure of 3D medical image alignment
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00091-0 · Cited by 2,180
Shedding light onto live molecular targets
Weissleder, R., & Ntziachristos, V. (2003) · Nature Medicine · doi:10.1038/nm0103-123 · Cited by 1,909
Hyperspectral image data analysis
Landgrebe, D. (2002) · IEEE Signal Processing Magazine · doi:10.1109/79.974718 · Cited by 1,152
Boundary conditions for the diffusion equation in radiative transfer
Haskell, R. C., Svaasand, L. O., Tsay, T.-T., Feng, T.-C., Tromberg, B. J., & McAdams, M. S. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.002727 · Cited by 1,138
BrainSuite: An automated cortical surface identification tool
Shattuck, D. W., & Leahy, R. M. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00054-3 · Cited by 859
Self-citation
Cited by
Medical hyperspectral imaging: a review
Lu, G., & Fei, B. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.1.010901 · Cited by 2,291
Optical tomography: forward and inverse problems
Arridge, S. R., & Schotland, J. C. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123010 · Cited by 625
Pre-clinical whole-body fluorescence imaging: Review of instruments, methods and applications
Leblond, F., Davis, S. C., Valdés, P. A., & Pogue, B. W. (2010) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/j.jphotobiol.2009.11.007 · Cited by 593
Digimouse: a 3D whole body mouse atlas from CT and cryosection data
Dogdas, B., Stout, D., Chatziioannou, A. F., & Leahy, R. M. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/3/003 · Cited by 524
Self-citationReview of spectral imaging technology in biomedical engineering: achievements and challenges
Li, Q., He, X., Wang, Y., Liu, H., Xu, D., & Guo, F. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.10.100901 · Cited by 479
In Vivo Molecular Bioluminescence Imaging: New Tools and Applications
Mezzanotte, L., van ‘t Root, M., Karatas, H., Goun, E. A., & Löwik, C. W. G. M. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2017.03.012 · Cited by 288
Darne, C., Lu, Y., & Sevick-Muraca, E. M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/1/r1 · Cited by 199
“…phantom: 4.4 MBq mouse: 11.1 MBq CW CLT/CT SP3 approximation to RTE with reconstruction using SVD CCD integration 1 min (phantom), 3 min (mouse) Chaudhari et al (2005) Four image projections using non-contact back-illuminated CCD detection with IVIS 200 imaging system with four mirrors (a)…”
MethodInfluentialMULTIMODALITY IN VIVO IMAGING SYSTEMS: Twice the Power or Double the Trouble?
Cherry, S. R. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095728 · Cited by 188
“Several groups have been making excellent progress toward quantitative 3-D optical (89) fluorescence (90, 91) and bioluminescence tomography (92, 93).”
Self-citationBioluminescent imaging: a critical tool in pre‐clinical oncology research
O'Neill, K., Lyons, S. K., Gallagher, W. M., Curran, K. M., & Byrne, A. T. (2010) · The Journal of Pathology · doi:10.1002/path.2656 · Cited by 174
“BLI has also been used to monitor the cell cycle [32].”
MethodGibson, A., & Dehghani, H. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2009.0080 · Cited by 159
Metadata
- Authors
- Chaudhari, A. J., Darvas, F., Bading, J. R., Moats, R. A., Conti, P. S., Smith, D. J., Cherry, S. R., & Leahy, R. M.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2005-11-08
- Volume
- 50
- Issue
- 23
- Pages
- 5421-5441
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2108870373
- Cited by
- 273
- References
- 22
- FWCI
- 14.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.