Three-dimensional simulation of ultrasound propagation through trabecular bone structures measured by synchrotron microtomography
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Three-dimensional numerical simulations of ultrasound transmission were performed through 31 trabecular bone samples measured by synchrotron microtomography. The synchrotron microtomography provided high resolution 3D mappings of bone structures, which were used as the input geometry in the simulation software developed in our laboratory. While absorption (i.e. the absorption of ultrasound through dissipative mechanisms) was not taken into account in the algorithm, the simulations reproduced major phenomena observed in real through-transmission experiments in trabecular bone. The simulated attenuation (i.e. the decrease of the transmitted ultrasonic energy) varies linearly with frequency in the MHz frequency range. Both the speed of sound (SOS) and the slope of the normalized frequency-dependent attenuation (nBUA) increase with the bone volume fraction. Twenty-five out of the thirty-one samples exhibited negative velocity dispersion. One sample was rotated to align the main orientation of the trabecular structure with the direction of ultrasonic propagation, leading to the observation of a fast and a slow wave. Coupling numerical simulation with real bone architecture therefore provides a powerful tool to investigate the physics of ultrasound propagation in trabecular structures. As an illustration, comparison between results obtained on bone modelled either as a fluid or a solid structure suggested the major role of mode conversion of the incident acoustic wave to shear waves in bone to explain the large contribution of scattering to the overall attenuation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hans, D., Dargent-Molina, P., Schott, A., Sebert, J., Cormier, C., Kotzki, P., Delmas, P., Pouilles, J., Breart, G., & Meunier, P. (1996) · The Lancet · doi:10.1016/s0140-6736(95)11456-4 · Cited by 1,066 · cited 1×
“Measurements of the speed of sound (SOS) and the slope of the frequency-dependent attenuation (BUA) are now established clinical modalities for fracture risk prediction (Chappard et al 1997, Hans et al 1996, 2004, Khaw et al 2004, Padilla et al 2004).”
MethodThe Measurement of Broadband Ultrasonic Attenuation in Cancellous Bone
Langton, C. M., Palmer, S. B., & Porter, R. W. (1984) · Engineering in Medicine · doi:10.1243/emed_jour_1984_013_022_02 · Cited by 672 · cited 1×
“…that are listed below remained poorly understood from a physical point of view: (1) attenuation varies linearly with frequency (Chaffai et al 2000, Langton et al 1984, Wear 2001b), (2) both the sound velocity and the slope of the frequency-dependent attenuation are highly correlated to the volume…”
BackgroundThree quantitative ultrasound parameters reflect bone structure
Gluer, C. C., Wu, C. Y., Jergas, M., Goldstein, S. A., & Genant, H. K. (1994) · Calcified Tissue International · doi:10.1007/bf00310168 · Cited by 424 · cited 1×
“Despite experimental evidence showing that QUS parameters could reflect additional information that is not captured by x-ray densitometry (Glüer et al 1994, Jenson et al 2003), it has not been possible yet to extract this information from ultrasound measurement (i.e. to solve the inverse problem)…”
BackgroundKhaw, K.-T., Reeve, J., Luben, R., Bingham, S., Welch, A., Wareham, N., Oakes, S., & Day, N. (2004) · The Lancet · doi:10.1016/s0140-6736(03)15325-1 · Cited by 277
A synchrotron radiation microtomography system for the analysis of trabecular bone samples
Salomé, M., Peyrin, F., Cloetens, P., Odet, C., Laval-Jeantet, A.-M., Baruchel, J., & Spanne, P. (1999) · Medical Physics · doi:10.1118/1.598736 · Cited by 275 · cited 1×
“The acquisition setup is based on 3D parallel tomography and has been previously described in detail (Salome et al 1999).”
MethodSelf-citationHans, D., Arlot, M. E., Schott, A. M., Roux, J. P., Kotzki, P. O., & Meunier, P. J. (1995) · Bone · doi:10.1016/8756-3282(94)00041-7 · Cited by 201 · cited 1×
“…and the slope of the frequency-dependent attenuation are highly correlated to the volume fraction of bone (i.e. the porosity) (Chaffai et al 2002, Hans et al 1995, Nicholson et al 2001), (3) the velocity dispersion is usually negative but sometimes positive (Droin et al 1998, Nicholson et al…”
BackgroundThe effects of remodeling on the elastic properties of bone
Katz, J. L., Yoon, H. S., Lipson, S. F., Maharidge, R. L., Meunier, A., & Christel, P. (1984) · Calcified Tissue International · doi:10.1007/bf02406131 · Cited by 147
Ultrasonic propagation in cancellous bone: a new stratified model
Hughes, E. R., Leighton, T. G., Petley, G. W., & White, P. R. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00034-4 · Cited by 140
Computational methods for ultrasonic bone assessment
Luo, G., Kaufman, J. J., Chiabrera, A., Bianco, B., Kinney, J. H., Haupt, D. L., Ryaby, J. T., & Siffert, R. S. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00026-5 · Cited by 123 · cited 1×
“This approach has been proposed by Luo et al (1999) who investigated numerical wave propagation in 2D trabecular bone structures reconstructed from micro computed tomography (µCT) data.”
MethodUltrasonic attenuation in human calcaneus from 0.2 to 1.7 MHz
Wear, K. A. (2001) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.911743 · Cited by 80 · cited 6×
“Several attempts have been made to interpret the observations described above, including Biot’s theory (Fellah et al 2004, Hosokawa and Otani 1997), the multi-layer model (Hughes et al 1999, Padilla and Laugier 2000, Wear 2001a) or scattering model (Nicholson et al 2000) but with moderate success.”
BackgroundResultInfluential
Cited by
Bae, S., Liu, K., Pouliopoulos, A. N., Ji, R., Jiménez-Gambín, S., Yousefian, O., Kline-Schoder, A. R., Batts, A. J., Tsitsos, F. N., Kokossis, D., et al. (2024) · Theranostics · doi:10.7150/thno.94206 · Cited by 70
“Skull absorption was also modeled based on the CT image with a maximum absorption value of 0.68 dB/cm at the working frequency, assuming a linear frequency dependency [66,67].”
Influential
Metadata
- Authors
- Bossy, E., Padilla, F., Peyrin, F., & Laugier, P.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2005-11-08
- Volume
- 50
- Issue
- 23
- Pages
- 5545-5556
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2065809986
- Cited by
- 160
- References
- 10
- FWCI
- 12.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.