A motion-incorporated reconstruction method for gated PET studies
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Cardiac and respiratory motion artefacts in PET imaging have been traditionally resolved by acquiring the data in gated mode. However, gated PET images are usually characterized by high noise content due to their low photon statistics. In this paper, we present a novel 4D model for the PET imaging system, which can incorporate motion information to generate a motion-free image with all acquired data. A computer simulation and a phantom study were conducted to test the performance of this approach. The computer simulation was based on a digital phantom that was continuously scaled during data acquisition. The phantom study, on the other hand, used two spheres in a tank of water, all of which were filled with (18)F water. One of the spheres was stationary while the other moved in a sinusoidal fashion to simulate tumour motion in the thorax. Data were acquired using both 4D CT and gated PET. Motion information was derived from the 4D CT images and then used in the 4D PET model. Both studies showed that this 4D PET model had a good motion-compensating capability. In the phantom study, this approach reduced quantification error of the radioactivity concentration by 95% when compared to a corresponding static acquisition, while signal-to-noise ratio was improved by 210% when compared to a corresponding gated image.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265 · cited 1×
“The registration of CT images was implemented within an ITK framework (Yoo et al 2002, Ibanez et al 2005) using a cubic B-spline based non-rigid transformation model (Rueckert et al 1999, Mattes et al 2003), along with a mean-square-error similarity criterion.”
MethodMaximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Cited by
Deep learning in medical image registration: a review
Fu, Y., Lei, Y., Wang, T., Curran, W. J., Liu, T., & Yang, X. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab843e · Cited by 661
Respiratory Motion in Positron Emission Tomography/Computed Tomography: A Review
Nehmeh, S. A., & Erdi, Y. E. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2008.01.002 · Cited by 317
Lamare, F., Carbayo, M. J. L., Cresson, T., Kontaxakis, G., Santos, A., Rest, C. C. L., Reader, A. J., & Visvikis, D. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/17/006 · Cited by 259
The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging
Liu, C., Pierce II, L. A., Alessio, A. M., & Kinahan, P. E. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/24/007 · Cited by 232
“…Lu et al 2006, Wink et al 2006), deep-inspiration-breathhold (DIBH) PET/CT (Kawano et al 2008, Meirelles et al 2007, Nehmeh et al 2007), postprocessing methods (Dawood et al 2006, Yamazaki et al 2006) and motion-corrected PET reconstruction (Lamare et al 2007, Li et al 2006, Qiao et al 2006, 2007).”
MethodAdvances in 4D Medical Imaging and 4D Radiation Therapy
Li, G., Citrin, D., Camphausen, K., Mueller, B., Burman, C., Mychalczak, B., Miller, R. W., & Song, Y. (2008) · Technology in Cancer Research & Treatment · doi:10.1177/153303460800700109 · Cited by 177
Metadata
- Authors
- Qiao, F., Pan, T., Clark, J. W., & Mawlawi, O. R.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2006-07-20
- Volume
- 51
- Issue
- 15
- Pages
- 3769-3783
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2070480087
- Cited by
- 239
- References
- 2
- FWCI
- 13.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.