Deformable registration of the planning image (kVCT) and the daily images (MVCT) for adaptive radiation therapy
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
The incorporation of daily images into the radiotherapy process leads to adaptive radiation therapy (ART), in which the treatment is evaluated periodically and the plan is adaptively modified for the remaining course of radiotherapy. Deformable registration between the planning image and the daily images is a key component of ART. In this paper, we report our researches on deformable registration between the planning kVCT and the daily MVCT image sets. The method is based on a fast intensity-based free-form deformable registration technique. Considering the noise and contrast resolution differences between the kVCT and the MVCT, an 'edge-preserving smoothing' is applied to the MVCT image prior to the deformable registration process. We retrospectively studied daily MVCT images from commercial TomoTherapy machines from different clinical centers. The data set includes five head-neck cases, one pelvis case, two lung cases and one prostate case. Each case has one kVCT image and 20-40 MVCT images. We registered the MVCT images with their corresponding kVCT image. The similarity measures and visual inspections of contour matches by physicians validated this technique. The applications of deformable registration in ART, including 'deformable dose accumulation', 'automatic re-contouring' and 'tumour growth/regression evaluation' throughout the course of radiotherapy are also studied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
Image registration methods: a survey
Zitová, B., & Flusser, J. (2003) · Image and Vision Computing · doi:10.1016/s0262-8856(03)00137-9 · Cited by 6,423 · cited 2×
“There are many approaches for deformable registration (Bajcsy and Kovacic 1989, Thirion 1998, Rogelj and Kovacic 2001, Zitova and Flusser 2003, Lu et al 2004, Coselmon et al 2004, Rohlfing et al 2004, Wang et al 2005, Brock et al 2005, Schreibmann and Xing 2005).”
MethodMultimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547 · cited 2×
“Intensity-based methods use similarity measures such as the sum of squared distance (SSD) and mutual information (MI) (Studholme et al 1999, Maes et al 1997, Pluim et al 2003) between images.”
MethodMutual-information-based registration of medical images: a survey
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815867 · Cited by 2,890
Image matching as a diffusion process: an analogy with maxwell’s demons
Thirion, J.-P. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80022-4 · Cited by 2,445
An overlap invariant entropy measure of 3D medical image alignment
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00091-0 · Cited by 2,180 · cited 2×
“Intensity-based methods use similarity measures such as the sum of squared distance (SSD) and mutual information (MI) (Studholme et al 1999, Maes et al 1997, Pluim et al 2003) between images.”
MethodBlack, M. J., Sapiro, G., Marimont, D. H., & Heeger, D. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.661192 · Cited by 1,295
Multiresolution elastic matching
Bajcsy, R., & Kovačič, S. (1989) · Computer Vision, Graphics, and Image Processing · doi:10.1016/s0734-189x(89)80014-3 · Cited by 1,106 · cited 2×
“There are many approaches for deformable registration (Bajcsy and Kovacic 1989, Thirion 1998, Rogelj and Kovacic 2001, Zitova and Flusser 2003, Lu et al 2004, Coselmon et al 2004, Rohlfing et al 2004, Wang et al 2005, Brock et al 2005, Schreibmann and Xing 2005).”
MethodYan, D., Vicini, F., Wong, J., & Martinez, A. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/1/008 · Cited by 761
Wang, H., Dong, L., O'Daniel, J., Mohan, R., Garden, A. S., Ang, K. K., Kuban, D. A., Bonnen, M., Chang, J. Y., & Cheung, R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/12/011 · Cited by 610 · cited 3×
“There are many approaches for deformable registration (Bajcsy and Kovacic 1989, Thirion 1998, Rogelj and Kovacic 2001, Zitova and Flusser 2003, Lu et al 2004, Coselmon et al 2004, Rohlfing et al 2004, Wang et al 2005, Brock et al 2005, Schreibmann and Xing 2005).”
Method
Cited by
Castillo, R., Castillo, E., Guerra, R., Johnson, V. E., McPhail, T., Garg, A. K., & Guerrero, T. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/7/001 · Cited by 592
Lagendijk, J. J. W., Raaymakers, B. W., Raaijmakers, A. J. E., Overweg, J., Brown, K. J., Kerkhof, E. M., van der Put, R. W., Hårdemark, B., van Vulpen, M., & van der Heide, U. A. (2008) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2007.10.034 · Cited by 511
Veiga, C., McClelland, J., Moinuddin, S., Lourenço, A., Ricketts, K., Annkah, J., Modat, M., Ourselin, S., D'Souza, D., & Royle, G. (2014) · Medical Physics · doi:10.1118/1.4864240 · Cited by 216
Advances in 4D Medical Imaging and 4D Radiation Therapy
Li, G., Citrin, D., Camphausen, K., Mueller, B., Burman, C., Mychalczak, B., Miller, R. W., & Song, Y. (2008) · Technology in Cancer Research & Treatment · doi:10.1177/153303460800700109 · Cited by 177
The need for application‐based adaptation of deformable image registration
Kirby, N., Chuang, C., Ueda, U., & Pouliot, J. (2013) · Medical Physics · doi:10.1118/1.4769114 · Cited by 164
Metadata
- Authors
- Lu, W., Olivera, G. H., Chen, Q., Ruchala, K. J., Haimerl, J., Meeks, S. L., Langen, K. M., & Kupelian, P. A.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2006-08-15
- Volume
- 51
- Issue
- 17
- Pages
- 4357-4374
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2007638243
- Cited by
- 159
- References
- 29
- FWCI
- 12.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.