Deformable registration of the planning image (kVCT) and the daily images (MVCT) for adaptive radiation therapy
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
The incorporation of daily images into the radiotherapy process leads to adaptive radiation therapy (ART), in which the treatment is evaluated periodically and the plan is adaptively modified for the remaining course of radiotherapy. Deformable registration between the planning image and the daily images is a key component of ART. In this paper, we report our researches on deformable registration between the planning kVCT and the daily MVCT image sets. The method is based on a fast intensity-based free-form deformable registration technique. Considering the noise and contrast resolution differences between the kVCT and the MVCT, an 'edge-preserving smoothing' is applied to the MVCT image prior to the deformable registration process. We retrospectively studied daily MVCT images from commercial TomoTherapy machines from different clinical centers. The data set includes five head-neck cases, one pelvis case, two lung cases and one prostate case. Each case has one kVCT image and 20-40 MVCT images. We registered the MVCT images with their corresponding kVCT image. The similarity measures and visual inspections of contour matches by physicians validated this technique. The applications of deformable registration in ART, including 'deformable dose accumulation', 'automatic re-contouring' and 'tumour growth/regression evaluation' throughout the course of radiotherapy are also studied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
Image registration methods: a survey
Zitová, B., & Flusser, J. (2003) · Image and Vision Computing · doi:10.1016/s0262-8856(03)00137-9 · Cited by 6,423 · cited 2×
“There are many approaches for deformable registration (Bajcsy and Kovacic 1989, Thirion 1998, Rogelj and Kovacic 2001, Zitova and Flusser 2003, Lu et al 2004, Coselmon et al 2004, Rohlfing et al 2004, Wang et al 2005, Brock et al 2005, Schreibmann and Xing 2005).”
MethodMultimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547 · cited 2×
“Intensity-based methods use similarity measures such as the sum of squared distance (SSD) and mutual information (MI) (Studholme et al 1999, Maes et al 1997, Pluim et al 2003) between images.”
MethodMutual-information-based registration of medical images: a survey
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815867 · Cited by 2,890
Image matching as a diffusion process: an analogy with maxwell’s demons
Thirion, J.-P. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80022-4 · Cited by 2,445
An overlap invariant entropy measure of 3D medical image alignment
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00091-0 · Cited by 2,180 · cited 2×
“Intensity-based methods use similarity measures such as the sum of squared distance (SSD) and mutual information (MI) (Studholme et al 1999, Maes et al 1997, Pluim et al 2003) between images.”
MethodBlack, M. J., Sapiro, G., Marimont, D. H., & Heeger, D. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.661192 · Cited by 1,295
Multiresolution elastic matching
Bajcsy, R., & Kovačič, S. (1989) · Computer Vision, Graphics, and Image Processing · doi:10.1016/s0734-189x(89)80014-3 · Cited by 1,106 · cited 2×
“There are many approaches for deformable registration (Bajcsy and Kovacic 1989, Thirion 1998, Rogelj and Kovacic 2001, Zitova and Flusser 2003, Lu et al 2004, Coselmon et al 2004, Rohlfing et al 2004, Wang et al 2005, Brock et al 2005, Schreibmann and Xing 2005).”
MethodYan, D., Vicini, F., Wong, J., & Martinez, A. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/1/008 · Cited by 761
Wang, H., Dong, L., O'Daniel, J., Mohan, R., Garden, A. S., Ang, K. K., Kuban, D. A., Bonnen, M., Chang, J. Y., & Cheung, R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/12/011 · Cited by 610 · cited 3×
“There are many approaches for deformable registration (Bajcsy and Kovacic 1989, Thirion 1998, Rogelj and Kovacic 2001, Zitova and Flusser 2003, Lu et al 2004, Coselmon et al 2004, Rohlfing et al 2004, Wang et al 2005, Brock et al 2005, Schreibmann and Xing 2005).”
MethodA survey of hierarchical non-linear medical image registration
Lester, H., & Arridge, S. R. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00095-8 · Cited by 484 · cited 2×
“Fast and fully automatic deformable registration among multi-modality medical images is still a challenging problem ( Lester and Arridge 1999, Likar and Pernus 2001 ,G eeet al 2003).”
BackgroundAccuracy of finite element model‐based multi‐organ deformable image registration
Brock, K. K., Sharpe, M. B., Dawson, L. A., Kim, S. M., & Jaffray, D. A. (2005) · Medical Physics · doi:10.1118/1.1915012 · Cited by 375
Rietzel, E., Chen, G. T. Y., Choi, N. C., & Willet, C. G. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.11.037 · Cited by 330 · cited 1×
“ART requires many techniques, such as dose reconstruction (Kapatoes et al 2001), dose accumulation (Yan et al 1999, Olivera et al 2003, Rietzel et al 2005, Keall et al 2005), treatment evaluation (Vargas et al 2005), re-contouring (Lu et al 2006) and re-optimization (Wu et al 2002, 2004).”
MethodFour‐dimensional radiotherapy planning for DMLC‐based respiratory motion tracking
Keall, P., Joshi, S. C., Vedam, S. S., Siebers, J. V., Kini, V. R., & Mohan, R. (2005) · Medical Physics · doi:10.1118/1.1879152 · Cited by 318
Rohlfing, T., Maurer, C. R., O'Dell, W. G., & Zhong, J. (2004) · Medical Physics · doi:10.1118/1.1644513 · Cited by 262 · cited 1×
“There are many approaches for deformable registration (Bajcsy and Kovacic 1989, Thirion 1998, Rogelj and Kovacic 2001, Zitova and Flusser 2003, Lu et al 2004, Coselmon et al 2004, Rohlfing et al 2004, Wang et al 2005, Brock et al 2005, Schreibmann and Xing 2005).”
MethodMegavoltage CT on a tomotherapy system
Ruchala, K. J., Olivera, G. H., Schloesser, E. A., & Mackie, T. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/10/316 · Cited by 261
Self-citationFast free-form deformable registration via calculus of variations
Lu, W., Chen, M.-L., Olivera, G. H., Ruchala, K. J., & Mackie, T. R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/14/003 · Cited by 259 · cited 4×
“There are many approaches for deformable registration (Bajcsy and Kovacic 1989, Thirion 1998, Rogelj and Kovacic 2001, Zitova and Flusser 2003, Lu et al 2004, Coselmon et al 2004, Rohlfing et al 2004, Wang et al 2005, Brock et al 2005, Schreibmann and Xing 2005).”
MethodInfluentialSelf-citationA hierarchical approach to elastic registration based on mutual information
Likar, B., & Pernuš, F. (2001) · Image and Vision Computing · doi:10.1016/s0262-8856(00)00053-6 · Cited by 209 · cited 1×
“Fast and fully automatic deformable registration among multi-modality medical images is still a challenging problem (Lester and Arridge 1999, Likar and Pernus 2001, Gee et al 2003).”
BackgroundInitial experience with megavoltage (MV) CT guidance for daily prostate alignments
Langen, K., Zhang, Y., Andrews, R. D., Hurley, M. E., Meeks, S. L., Poole, D. O., Willoughby, T. R., & Kupelian, P. A. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2005.02.047 · Cited by 152 · cited 1×
“MVCT, as a standard helical TomoTherapy process, has been used routinely for patient setup in TomoTherapy treatments (Langen et al 2005, Forrest et al 2004, Meeks et al 2005).”
MethodSelf-citationForrest, L. J., Mackie, T. R., Ruchala, K., Turek, M., Kapatoes, J. M., Jaradat, H., Hui, S. K., Balog, J. P., Vail, D. M., & Mehta, M. P. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.08.016 · Cited by 141
Self-citationCoselmon, M. M., Balter, J. M., McShan, D. L., & Kessler, M. L. (2004) · Medical Physics · doi:10.1118/1.1803671 · Cited by 134
Re-optimization in adaptive radiotherapy
Wu, C., Jeraj, R., Olivera, G., & Mackie, T. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/17/309 · Cited by 122 · cited 2×
“ART requires many techniques, such as dose reconstruction (Kapatoes et al 2001), dose accumulation (Yan et al 1999 ,O liveraet al 2003, Rietzel et al 2005, Keall et al 2005), treatment evaluation (Vargas et al 2005), re-contouring (Lu et al 2006) and re-optimization ( Wu et al 2002, 2004 ).”
MethodSelf-citationAutomatic re-contouring in 4D radiotherapy
Lu, W., Olivera, G., Chen, Q., Chen, M.-L., & Ruchala, K. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/5/002 · Cited by 98 · cited 1×
“The incorporation of daily images into the radiotherapy process is essential for adaptive radiation therapy (ART) (Yan et al 1997a, 1997b, 1998, 2000, Lu et al 2000, Rehbinder et al 2004, Lam et al 2005).”
MethodSelf-citationFord, E. C., Chang, J., Mueller, K. D., Sidhu, K., Todor, D. A., Mageras, G. S., Yorke, E. D., Ling, C., & Amols, H. I. (2002) · Medical Physics · doi:10.1118/1.1517614 · Cited by 92 · cited 1×
“…et al 1983, Brahme et al 1987, Lewis et al 1992, Nakagawa et al 1997, Mosleh-Shirazi et al 1998a, 1998b, Hesse et al 1998, Guan and Zhu 1998, Ford et al 2002, Groh et al 2002, Seppi et al 2003, Welsh et al 2004, Pouliot et al 2005) have shown that the detected megavoltage projection…”
BackgroundLimited-data image registration for radiotherapy positioning and verification
Ruchala, K., Olivera, G., & Kapatoes, J. M. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02895-x · Cited by 62 · cited 2×
“The MVCT images were aligned with the kVCT image using the rigid-body alignment tool in the TomoTherapy image registration panel ( Ruchala et al 2002 ).”
MethodSelf-citationSchreibmann, E., & Xing, L. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2005.02.001 · Cited by 52 · cited 1×
“There are many approaches for deformable registration (Bajcsy and Kovacic 1989, Thirion 1998, Rogelj and Kovacic 2001, Zitova and Flusser 2003, Lu et al 2004, Coselmon et al 2004, Rohlfing et al 2004, Wang et al 2005, Brock et al 2005, Schreibmann and Xing 2005).”
MethodFast treatment plan modification with an over-relaxed Cimmino algorithm
Wu, C., Jeraj, R., Lu, W., & Mackie, T. (2004) · Medical Physics · doi:10.1118/1.1631913 · Cited by 40 · cited 1×
“ART requires many techniques, such as dose reconstruction (Kapatoes et al 2001), dose accumulation (Yan et al 1999, Olivera et al 2003, Rietzel et al 2005, Keall et al 2005), treatment evaluation (Vargas et al 2005), re-contouring (Lu et al 2006) and re-optimization (Wu et al 2002, 2004).”
MethodSelf-citationGuan, H., & Zhu, Y. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/10/018 · Cited by 40
A Generalization of Adaptive Radiotherapy and the Registration of Deformable Dose Distributions
Lu, W., Mackie, T. R., Keller, H., Ruchala, K., & Olivera, G. (2000) · Springer eBooks · doi:10.1007/978-3-642-59758-9_195 · Cited by 7 · cited 1×
“The incorporation of daily images into the radiotherapy process is essential for adaptive radiation therapy (ART) (Yan et al 1997a, 1997b, 1998, 2000, Lu et al 2000, Rehbinder et al 2004, Lam et al 2005).”
MethodSelf-citation
Cited by
Castillo, R., Castillo, E., Guerra, R., Johnson, V. E., McPhail, T., Garg, A. K., & Guerrero, T. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/7/001 · Cited by 592
Lagendijk, J. J. W., Raaymakers, B. W., Raaijmakers, A. J. E., Overweg, J., Brown, K. J., Kerkhof, E. M., van der Put, R. W., Hårdemark, B., van Vulpen, M., & van der Heide, U. A. (2008) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2007.10.034 · Cited by 511
Veiga, C., McClelland, J., Moinuddin, S., Lourenço, A., Ricketts, K., Annkah, J., Modat, M., Ourselin, S., D'Souza, D., & Royle, G. (2014) · Medical Physics · doi:10.1118/1.4864240 · Cited by 216
Advances in 4D Medical Imaging and 4D Radiation Therapy
Li, G., Citrin, D., Camphausen, K., Mueller, B., Burman, C., Mychalczak, B., Miller, R. W., & Song, Y. (2008) · Technology in Cancer Research & Treatment · doi:10.1177/153303460800700109 · Cited by 177
The need for application‐based adaptation of deformable image registration
Kirby, N., Chuang, C., Ueda, U., & Pouliot, J. (2013) · Medical Physics · doi:10.1118/1.4769114 · Cited by 164
Metadata
- Authors
- Lu, W., Olivera, G. H., Chen, Q., Ruchala, K. J., Haimerl, J., Meeks, S. L., Langen, K. M., & Kupelian, P. A.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2006-08-15
- Volume
- 51
- Issue
- 17
- Pages
- 4357-4374
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2007638243
- Cited by
- 159
- References
- 29
- FWCI
- 12.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.