A method of image registration for small animal, multi-modality imaging
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Many research institutions have a full suite of preclinical tomographic scanners to answer biomedical questions in vivo. Routine multi-modality imaging requires robust registration of images generated by various tomographs. We have implemented a hardware registration method for preclinical imaging that is similar to that used in the combined positron emission tomography (PET)/computed tomography (CT) scanners in the clinic. We designed an imaging chamber which can be rigidly and reproducibly mounted on separate microPET and microCT scanners. We have also designed a three-dimensional grid phantom with 1288 lines that is used to generate the spatial transformation matrix from software registration using a 15-parameter perspective model. The imaging chamber works in combination with the registration phantom synergistically to achieve the image registration goal. We verified that the average registration error between two imaging modalities is 0.335 mm using an in vivo mouse bone scan. This paper also estimates the impact of image misalignment on PET quantitation using attenuation corrections generated from misregistered images. Our technique is expected to produce PET quantitation errors of less than 5%. The methods presented are robust and appropriate for routine use in high throughput animal imaging facilities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093 · cited 1×
“A number of sophisticated software techniques to register sets of related intra- and intermodality images have been developed (Hill et al 2001).”
Method
Cited by
Bartlett, D. W., Su, H., Hildebrandt, I. J., Weber, W. A., & Davis, M. E. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0707461104 · Cited by 803
Guo, D., Hildebrandt, I. J., Prins, R. M., Soto, H., Mazzotta, M. M., Dang, J., Czernin, J., Shyy, J. Y.-J., Watson, A. D., Phelps, M., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0906606106 · Cited by 232
Radu, C. G., Shu, C. J., Nair-Gill, E., Shelly, S. M., Barrio, J. R., Satyamurthy, N., Phelps, M. E., & Witte, O. N. (2008) · Nature Medicine · doi:10.1038/nm1724 · Cited by 202
“We co-registered microPET and CT images as previously describe”
MethodNon‐Invasive in vivo Imaging in Small Animal Research
Koo, V., Hamilton, P. W., & Williamson, K. (2006) · Analytical Cellular Pathology · doi:10.1155/2006/245619 · Cited by 145
Wang, H., Stout, D. B., & Chatziioannou, A. F. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.02.009 · Cited by 16
Self-citation
Metadata
- Authors
- Chow, P. L., Stout, D. B., Komisopoulou, E., & Chatziioannou, A. F.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2006-01-04
- Volume
- 51
- Issue
- 2
- Pages
- 379-390
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2008290507
- Cited by
- 100
- References
- 1
- FWCI
- 9.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A method of image registration for small animal, multi-modality imaging. https://app.cochat.ai/papers/10.1088/0031-9155/51/2/013
- The paper
- Chow, P. L., Stout, D. B., Komisopoulou, E., & Chatziioannou, A. F. (2006). A method of image registration for small animal, multi-modality imaging. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/51/2/013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.