Spatiotemporal signal space separation method for rejecting nearby interference in MEG measurements
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Limitations of traditional magnetoencephalography (MEG) exclude some important patient groups from MEG examinations, such as epilepsy patients with a vagus nerve stimulator, patients with magnetic particles on the head or having magnetic dental materials that cause severe movement-related artefact signals. Conventional interference rejection methods are not able to remove the artefacts originating this close to the MEG sensor array. For example, the reference array method is unable to suppress interference generated by sources closer to the sensors than the reference array, about 20-40 cm. The spatiotemporal signal space separation method proposed in this paper recognizes and removes both external interference and the artefacts produced by these nearby sources, even on the scalp. First, the basic separation into brain-related and external interference signals is accomplished with signal space separation based on sensor geometry and Maxwell's equations only. After this, the artefacts from nearby sources are extracted by a simple statistical analysis in the time domain, and projected out. Practical examples with artificial current dipoles and interference sources as well as data from real patients demonstrate that the method removes the artefacts without altering the field patterns of the brain signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Golub, G. H., & Loan, C. F. V. (1996) · Johns Hopkins University Press eBooks · Cited by 6,027
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Signal-space projection method for separating MEG or EEG into components
Uusitalo, M. A., & Ilmoniemi, R. J. (1997) · Medical & Biological Engineering & Computing · doi:10.1007/bf02534144 · Cited by 913
Signal Processing in Magnetoencephalography
Vrba, J., & Robinson, S. E. (2001) · Methods · doi:10.1006/meth.2001.1238 · Cited by 716 · cited 3×
“These methods include e.g. gradiometric coil configurations (Zimmerman 1977), reference sensors (Vrba and Robinson 2001), signal space projection (SSP) (Uusitalo and Ilmoniemi 1997), and most recently the signal space separation (SSS) method (Taulu and Kajola 2005, Taulu et al 2005).”
BackgroundMethodApplications of the signal space separation method
Taulu, S., Simola, J., & Kajola, M. (2005) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2005.853302 · Cited by 548
Self-citationPresentation of electromagnetic multichannel data: The signal space separation method
Taulu, S., & Kajola, M. (2005) · Journal of Applied Physics · doi:10.1063/1.1935742 · Cited by 390
Self-citationSQUID instruments and shielding for low-level magnetic measurements
Zimmerman, J. E. (1977) · Journal of Applied Physics · doi:10.1063/1.323659 · Cited by 132
Cited by
MNE software for processing MEG and EEG data
Gramfort, A., Luessi, M., Larson, E., Engemann, D. A., Strohmeier, D., Brodbeck, C., Parkkonen, L., & Hämäläinen, M. S. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.027 · Cited by 1,951
Cichy, R. M., Khosla, A., Pantazis, D., Torralba, A., & Oliva, A. (2016) · Scientific Reports · doi:10.1038/srep27755 · Cited by 716
Good practice for conducting and reporting MEG research
Gross, J., Baillet, S., Barnes, G. R., Henson, R. N., Hillebrand, A., Jensen, O., Jerbi, K., Litvak, V., Maess, B., Oostenveld, R., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.10.001 · Cited by 738
Neural Mechanisms of Object-Based Attention
Baldauf, D., & Desimone, R. (2014) · Science · doi:10.1126/science.1247003 · Cited by 536
Broadband criticality of human brain network synchronization
Kitzbichler, M. G., Smith, M. L., Christensen, S. R., & Bullmore, E. (2009) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1000314 · Cited by 527
“The data set was corrected for the presence of internal and external noise sources and for disturbances as a result of head movements using signal space separation [40] with the spatiotemporal extension [41] via MaxFilter (Elekta Neuromag, Finland).”
Method
Metadata
- Authors
- Taulu, S., & Simola, J.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2006-03-16
- Volume
- 51
- Issue
- 7
- Pages
- 1759-1768
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1967125431
- Cited by
- 1,549
- References
- 7
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.