The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
MNE software for processing MEG and EEG data
Open accessAbstract
Magnetoencephalography and electroencephalography (M/EEG) measure the weak electromagnetic signals originating from neural currents in the brain. Using these signals to characterize and locate brain activity is a challenging task, as evidenced by several decades of methodological contributions. MNE, whose name stems from its capability to compute cortically-constrained minimum-norm current estimates from M/EEG data, is a software package that provides comprehensive analysis tools and workflows including preprocessing, source estimation, time–frequency analysis, statistical analysis, and several methods to estimate functional connectivity between distributed brain regions. The present paper gives detailed information about the MNE package and describes typical use cases while also warning about potential caveats in analysis. The MNE package is a collaborative effort of multiple institutes striving to implement and share best methods and to facilitate distribution of analysis pipelines to advance reproducibility of research. Full documentation is available at http://martinos.org/mne.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
Investigating causal relations by econometric models and cross-spectral methods
Granger, C. W. J. (1969) · Econometrica · doi:10.2307/1912791 · Cited by 22,989
Desikan, R. S., Ségonne, F., Fischl, B., Quinn, B. T., Dickerson, B. C., Blacker, D., Buckner, R. L., Dale, A. M., Maguire, R. P., Hyman, B. T., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.021 · Cited by 13,324
An algorithm for the machine calculation of complex Fourier series
Cooley, J. W., & Tukey, J. W. (1965) · Mathematics of Computation · doi:10.1090/s0025-5718-1965-0178586-1 · Cited by 13,154
Nonparametric statistical testing of EEG- and MEG-data
Maris, E., & Oostenveld, R. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.024 · Cited by 8,496
Nonparametric permutation tests for functional neuroimaging: A primer with examples
Nichols, T. E., & Holmes, A. P. (2002) · Human Brain Mapping · doi:10.1002/hbm.1058 · Cited by 6,256
Buzsáki, G. (2006) · doi:10.1093/acprof:oso/9780195301069.001.0001 · Cited by 4,873
Automatic parcellation of human cortical gyri and sulci using standard anatomical nomenclature
Destrieux, C., Fischl, B., Dale, A., & Halgren, E. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.010 · Cited by 2,956
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561
Neuronal gamma-band synchronization as a fundamental process in cortical computation
Fries, P. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135603 · Cited by 1,713
Research works printed but not linked: 76
- Aine, 2012, MEG-SIM: a web portal for testing MEG analysis methods using realistic simulated and empirical data, Neuroinformatics, 10, 141, 10.1007/s12021-011-9132-z · DOI
- Barnett, 2011, Behaviour of granger causality under filtering: theoretical invariance and practical application, J. Neurosci. Methods, 201, 404, 10.1016/j.jneumeth.2011.08.010 · DOI
- Besl, 1992, A method for registration of 3-d shapes, IEEE Trans. Pattern Anal. Mach. Intell., 14, 239, 10.1109/34.121791 · DOI · Paper page
- Dalal, 2011, MEG/EEG source reconstruction, statistical evaluation, and visualization with nutmeg, Comput. Intell. Neurosci., 2011, 10.1155/2011/758973 · DOI
- Dale, 1993, Improved localization of cortical activity by combining EEG and MEG with MRI cortical surface reconstruction: a linear approach, J. Cogn. Neurosci., 5, 162, 10.1162/jocn.1993.5.2.162 · DOI · Paper page
- Dale, 1999, Cortical surface-based analysis I: segmentation and surface reconstruction, NeuroImage, 9, 179, 10.1006/nimg.1998.0395 · DOI · Paper page
- Dale, 2000, Dynamic statistical parametric mapping: combining fMRI and MEG for high-resolution imaging of cortical activity, Neuron, 26, 55, 10.1016/S0896-6273(00)81138-1 · DOI · Paper page
- Delorme, 2011, EEGLAB, SIFT, NFT, BCILAB, and ERICA: new tools for advanced EEG processing, Intell. Neurosci, 10.1155/2011/130714 · DOI · Paper page
- Dubois, 2005, Maintaining correctness in scientific programs, Comput. Sci. Eng., 7, 80, 10.1109/MCSE.2005.54 · DOI
- Fischl, 1999, Cortical surface-based analysis II: inflation, flattening, and a surface-based coordinate system, NeuroImage, 9, 195, 10.1006/nimg.1998.0396 · DOI · Paper page
- Fischl, 2004, Automatically parcellating the human cerebral cortex, Cereb. Cortex, 14, 11, 10.1093/cercor/bhg087 · DOI · Paper page
- Florin, 2010, The effect of filtering on granger causality based multivariate causality measures, NeuroImage, 50, 577, 10.1016/j.neuroimage.2009.12.050 · DOI
- Friston, 1994, Functional and effective connectivity in neuroimaging: a synthesis, Hum. Brain Mapp., 2, 56, 10.1002/hbm.460020107 · DOI · Paper page
- Fuchs, 1999, Linear and nonlinear current density reconstructions, J. Clin. Neurophysiol., 16, 267, 10.1097/00004691-199905000-00006 · DOI · Paper page
- George, 2004, A structured experiment of test-driven development, Inf. Softw. Technol., 46, 337, 10.1016/j.infsof.2003.09.011 · DOI · Paper page
- Ghuman, 2011, A wavelet-based method for measuring the oscillatory dynamics of resting-state functional connectivity in MEG, NeuroImage, 56, 69, 10.1016/j.neuroimage.2011.01.046 · DOI
- Gorgolewski, 2011, Nipype: a flexible, lightweight and extensible neuroimaging data processing framework in python, Front. Neuroinform., 5
- Gramfort, 2010, OpenMEEG: opensource software for quasistatic bioelectromagnetics, Biomed. Eng. Online, 9, 45, 10.1186/1475-925X-9-45 · DOI · Paper page
- Gramfort, 2012, Mixed-norm estimates for the M/EEG inverse problem using accelerated gradient methods, Phys. Med. Biol., 57, 1937, 10.1088/0031-9155/57/7/1937 · DOI · Paper page
- Gross, 2001, Dynamic imaging of coherent sources: studying neural interactions in the human brain, Proc. Natl. Acad. Sci., 98, 694, 10.1073/pnas.98.2.694 · DOI · Paper page
- Gross, 2013, Good practice for conducting and reporting MEG research, NeuroImage, 65, 349, 10.1016/j.neuroimage.2012.10.001 · DOI · Paper page
- Hämäläinen, 1994, Interpreting magnetic fields of the brain: minimum norm estimates, Med. Biol. Eng. Comput., 32, 35, 10.1007/BF02512476 · DOI · Paper page
- Hämäläinen, 1993, Magnetoencephalography — theory, instrumentation, and applications to noninvasive studies of the working human brain, Rev. Mod. Phys., 65, 413, 10.1103/RevModPhys.65.413 · DOI · Paper page
- Hari, 1991, On brain's magnetic responses to sensory stimuli, J. Clin. Neurophysiol., 8, 157, 10.1097/00004691-199104000-00004 · DOI
- Hari, 1997, Human cortical oscillations: a neuromagnetic view through the skull, Trends Neurosci., 20, 44, 10.1016/S0166-2236(96)10065-5 · DOI · Paper page
- Haufe, 2012, A critical assessment of connectivity measures for EEG data: a simulation study, NeuroImage, 64, 120, 10.1016/j.neuroimage.2012.09.036 · DOI · Paper page
- Hillebrand, 2003, The use of anatomical constraints with MEG beamformers, NeuroImage, 20, 2302, 10.1016/j.neuroimage.2003.07.031 · DOI
- Hipp, 2012, Large-scale cortical correlation structure of spontaneous oscillatory activity, Nat. Neurosci., 15, 884, 10.1038/nn.3101 · DOI · Paper page
- Hyvärinen, 2000, Independent component analysis: algorithms and applications, Neural Netw., 13, 411, 10.1016/S0893-6080(00)00026-5 · DOI · Paper page
- Jung, 2000, Removing electroencephalographic artifacts by blind source separation, Psychophysiology, 37, 163, 10.1111/1469-8986.3720163 · doi:10.1111/1469-8986.3720163 · Paper page
- Kybic, 2005, A common formalism for the integral formulations of the forward EEG problem, IEEE Trans. Med. Imaging, 24, 12, 10.1109/TMI.2004.837363 · DOI · Paper page
- Lachaux, 1999, Measuring phase synchrony in brain signals, Hum. Brain Mapp., 8, 194, 10.1002/(SICI)1097-0193(1999)8:4<194::AID-HBM4>3.0.CO;2-C · DOI
- Larson, 2013, The cortical dynamics underlying effective switching of auditory spatial attention, NeuroImage, 64, 365, 10.1016/j.neuroimage.2012.09.006 · DOI
- Lin, 2004, Spectral spatiotemporal imaging of cortical oscillations and interactions in the human brain, NeuroImage, 23, 582, 10.1016/j.neuroimage.2004.04.027 · DOI
- Lin, 2004, Spectral spatiotemporal imaging of cortical oscillations and interactions in the human brain, NeuroImage, 23, 582, 10.1016/j.neuroimage.2004.04.027 · DOI
- Lin, 2006, Distributed current estimates using cortical orientation constraints, Hum. Brain Mapp., 27, 1, 10.1002/hbm.20155 · DOI · Paper page
- Lin, 2006, Assessing and improving the spatial accuracy in MEG source localization by depth-weighted minimum-norm estimates, NeuroImage, 31, 160, 10.1016/j.neuroimage.2005.11.054 · DOI · Paper page
- Litvak, 2011, EEG and MEG data analysis in SPM8, Comput. Intell. Neurosci., 2011, 852961, 10.1155/2011/852961 · DOI · Paper page
- Liu, 1998, Spatiotemporal imaging of human brain activity using functional mri constrained magnetoencephalography data: Monte Carlo simulations, Proc. Natl. Acad. Sci. U. S. A., 95, 8945, 10.1073/pnas.95.15.8945 · DOI · Paper page
- Martinsson, 2011, A randomized algorithm for the decomposition of matrices, Appl. Comput. Harmon. Anal., 30, 47, 10.1016/j.acha.2010.02.003 · DOI · Paper page
- Matsuura, 1995, Selective minimum-norm solution of the biomagnetic inverse problem, IEEE Trans. Biomed. Eng., 42, 608, 10.1109/10.387200 · DOI · Paper page
- 2011, vol. 11
- Morlet, 1982, Wave propagation and sampling theory: part I: complex signal and scattering multilayered-part II: sampling theory and complex waves, Geophysics, 47, 203, 10.1190/1.1441328 · DOI · Paper page
- Mosher, 1998, Recursive MUSIC: a framework for EEG and MEG source localization, IEEE Trans. Biomed. Eng., 45, 1342, 10.1109/10.725331 · DOI · Paper page
- Mosher, 1999, EEG and MEG: forward solutions for inverse methods, IEEE Trans. Biomed. Eng., 46, 245, 10.1109/10.748978 · DOI · Paper page
- Nolte, 2004, Identifying true brain interaction from EEG data using the imaginary part of coherency, Clin. Neurophysiol., 115, 2292, 10.1016/j.clinph.2004.04.029 · DOI · Paper page
- Oostenveld, 2011, FieldTrip: open source software for advanced analysis of MEG, EEG, and invasive electrophysiological data, Comput. Intell. Neurosci, 2011, 156869, 10.1155/2011/156869 · DOI · Paper page
- Ou, 2009, A distributed spatio-temporal EEG/MEG inverse solver, NeuroImage, 44, 932, 10.1016/j.neuroimage.2008.05.063 · DOI · Paper page
- Pantazis, 2005, A comparison of random field theory and permutation methods for the statistical analysis of MEG data, NeuroImage, 25, 383, 10.1016/j.neuroimage.2004.09.040 · DOI
- Pascual-Marqui, 2002, Standardized low resolution brain electromagnetic tomography (sLORETA): technical details, Methods Find. Exp. Clin. Pharmacol., 24, 5
- Pedregosa, 2011, Scikit-learn: machine learning in Python, J. Mach. Learn. Res., 12, 2825
- Pérez, 2007, IPython: a system for interactive scientific computing, Comput. Sci. Eng., 9, 21, 10.1109/MCSE.2007.53 · DOI · Paper page
- Prlić, 2012, Ten simple rules for the open development of scientific software, PLoS Comput. Biol., 8, 10.1371/journal.pcbi.1002802 · DOI
- Ridgway, 2012, The problem of low variance voxels in statistical parametric mapping; a new hat avoids a “haircut”, NeuroImage, 59, 2131, 10.1016/j.neuroimage.2011.10.027 · DOI
- Scherg, 1985, Two bilateral sources of the late AEP as identified by a spatio-temporal dipole model, Electroencephalogr. Clin. Neurophysiol., 62, 32, 10.1016/0168-5597(85)90033-4 · DOI · Paper page
- Schoffelen, 2009, Source connectivity analysis with MEG and EEG, Hum. Brain Mapp., 30, 1857, 10.1002/hbm.20745 · DOI · Paper page
- Sorrentino, 2009, Dynamical MEG source modeling with multi-target Bayesian filtering, Hum. Brain Mapp., 30, 1911, 10.1002/hbm.20786 · DOI
- Stam, 2007, Phase lag index: assessment of functional connectivity from multi channel EEG and MEG with diminished bias from common sources, Hum. Brain Mapp., 28, 1178, 10.1002/hbm.20346 · DOI · Paper page
- Stenbacka, 2002, Comparison of minimum current estimate and dipole modeling in the analysis of simulated activity in the human visual cortices, NeuroImage, 16, 936, 10.1006/nimg.2002.1151 · DOI
- Stenroos, 2012, Bioelectromagnetic forward problem: isolated source approach revis(it)ed, Phys. Med. Biol., 57, 3517, 10.1088/0031-9155/57/11/3517 · DOI
- Tadel, 2011, Brainstorm: a user-friendly application for MEG/EEG analysis, Comput. Intell. Neurosci., 2011, 879716, 10.1155/2011/879716 · DOI · Paper page
- Tallon-Baudry, 1999, Oscillatory gamma activity in humans and its role in object representation, Trends Cogn. Sci., 3, 151, 10.1016/S1364-6613(99)01299-1 · DOI · Paper page
- Tallon-Baudry, 1997, Combined EEG and MEG recordings of visual 40Hz responses to illusory triangles in human, Neuroreport, 5, 1103, 10.1097/00001756-199703240-00008 · DOI
- Taulu, 2006, Spatiotemporal signal space separation method for rejecting nearby interference in MEG measurements, Phys. Med. Biol., 51, 1759, 10.1088/0031-9155/51/7/008 · DOI · Paper page
- Taulu, 2005, Applications of the signal space separation method, IEEE Trans. Signal Process., 53, 3359, 10.1109/TSP.2005.853302 · DOI · Paper page
- Thomson, 1982, Spectrum estimation and harmonic analysis, Proc. IEEE, 70, 1055, 10.1109/PROC.1982.12433 · DOI · Paper page
- Uusitalo, 1997, Signal-space projection method for separating MEG or EEG into components, Med. Biol. Eng. Comput., 35, 135, 10.1007/BF02534144 · DOI · Paper page
- Uutela, 1999, Visualization of magnetoencephalographic data using minimum current estimates, NeuroImage, 10, 173, 10.1006/nimg.1999.0454 · DOI · Paper page
- Uutela, 2001, Detecting and correcting for head movements in neuromagnetic measurements, NeuroImage, 14, 1424, 10.1006/nimg.2001.0915 · DOI
- Van der Walt, 2011, The NumPy array: a structure for efficient numerical computation, Comput. Sci. Eng., 11
- Van Essen, 2012, The Human Connectome Project: a data acquisition perspective, NeuroImage, 62, 2222, 10.1016/j.neuroimage.2012.02.018 · DOI · Paper page
- Vinck, 2010, The pairwise phase consistency: a bias-free measure of rhythmic neuronal synchronization, NeuroImage, 51, 112, 10.1016/j.neuroimage.2010.01.073 · DOI · Paper page
- Vinck, 2011, An improved index of phase-synchronization for electrophysiological data in the presence of volume-conduction, noise and sample-size bias, NeuroImage, 55, 1548, 10.1016/j.neuroimage.2011.01.055 · DOI · Paper page
- Welch, 1967, The use of fast Fourier transform for the estimation of power spectra: a method based on time averaging over short, modified periodograms, IEEE Trans. Audio Electroacoust., 15, 70, 10.1109/TAU.1967.1161901 · DOI · Paper page
- Wipf, 2009, A unified Bayesian framework for MEG/EEG source imaging, NeuroImage, 44, 947, 10.1016/j.neuroimage.2008.02.059 · DOI · Paper page
- Wolters, 2007, Numerical mathematics of the subtraction method for the modeling of a current dipole in EEG source reconstruction using finite element head models, SIAM J. Sci. Comput., 30, 24, 10.1137/060659053 · DOI
Cited by
Michalareas, G., Vezoli, J., van Pelt, S., Schoffelen, J.-M., Kennedy, H., & Fries, P. (2016) · Neuron · doi:10.1016/j.neuron.2015.12.018 · Cited by 696
A hierarchy of linguistic predictions during natural language comprehension
Heilbron, M., Armeni, K., Schoffelen, J.-M., Hagoort, P., & de Lange, F. P. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2201968119 · Cited by 343
Robust EEG-based cross-site and cross-protocol classification of states of consciousness
Engemann, D. A., Raimondo, F., King, J.-R., Rohaut, B., Louppe, G., Faugeras, F., Annen, J., Cassol, H., Gosseries, O., Fernandez-Slezak, D., et al. (2018) · Brain · doi:10.1093/brain/awy251 · Cited by 329
Self-citationMeasuring MEG Closer to the Brain: Performance of on-Scalp Sensor Arrays
Iivanainen, J., Stenroos, M., & Parkkonen, L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.048 · Cited by 296
“, 2004) implemented in FreeSurfer and MNE software (Gramfort et al., 2014) to segment the brain, skull and scalp compartments.”
Self-citationElectrophysiological source imaging: A noninvasive window to brain dynamics
He, B., Sohrabpour, A., Brown, E., & Liu, Z. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-120853 · Cited by 297
Metadata
- Authors
- Gramfort, A., Luessi, M., Larson, E., Engemann, D. A., Strohmeier, D., Brodbeck, C., Parkkonen, L., & Hämäläinen, M. S.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2014-02
- Volume
- 86
- Pages
- 446-460
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2135595031
- Cited by
- 1,951
- References
- 16
- FWCI
- 21.71
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Funders
- National Institute of Biomedical Imaging and Bioengineering (5R01EB009048, P41RR014075)
- National Institute on Deafness and Other Communication Disorders (F32DC012456)
- NSF (0958669, 1042134)
- ERC-YStG-263584
- aivoAALTO
- Swiss National Science Foundation Early Postdoc. Mobility (148485)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MNE software for processing MEG and EEG data. https://app.cochat.ai/papers/10.1016/j.neuroimage.2013.10.027
- The paper
- Gramfort, A., Luessi, M., Larson, E., Engemann, D. A., Strohmeier, D., Brodbeck, C., Parkkonen, L., & Hämäläinen, M. S. (2014). MNE software for processing MEG and EEG data. NeuroImage. https://doi.org/10.1016/j.neuroimage.2013.10.027
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.