Classification of movement intention by spatially filtered electromagnetic inverse solutions
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
We couple standardized low-resolution electromagnetic tomography, an inverse solution for electroencephalography (EEG) and the common spatial pattern, which is here conceived as a data-driven beamformer, to classify the benchmark BCI (brain-computer interface) competition 2003, data set IV. The data set is from an experiment where a subject performed a self-paced left and right finger tapping task. Available for analysis are 314 training trials whereas 100 unlabelled test trials have to be classified. The EEG data from 28 electrodes comprise the recording of the 500 ms before the actual finger movements, hence represent uniquely the left and right finger movement intention. Despite our use of an untrained classifier, and our extraction of only one attribute per class, our method yields accuracy similar to the winners of the competition for this data set. The distinct advantages of the approach presented here are the use of an untrained classifier and the processing speed, which make the method suitable for actual BCI applications. The proposed method is favourable over existing classification methods based on an EEG inverse solution, which rely either on iterative algorithms for single-trial independent component analysis or on trained classifiers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927 · cited 1×
“A major line of research pursues this goal by the acquisition of volitional control over the production of specific brain activities (K¨ubler et al 2001, Wolpaw et al 2002).”
BackgroundBeamforming: a versatile approach to spatial filtering
Van Veen, B. D., & Buckley, K. M. (1988) · IEEE ASSP Magazine · doi:10.1109/53.665 · Cited by 3,901
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561 · cited 4×
“As long as the sources are spatially segregated, the linear superposition principle holds and sources may as well be composed of clusters of neuronal populations, physiologically connected, but possibly far away from each other in space (Van Veen et al 1997).”
BackgroundMethodInfluentialOptimal spatial filtering of single trial EEG during imagined hand movement
Ramoser, H., Muller-Gerking, J., & Pfurtscheller, G. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895946 · Cited by 2,457 · cited 2×
“Several authors applied the CSP to EEG data for the purpose of extraction of abnormal EEG components (Koles 1991), EEG source localization (Koles and Soong 1998) and for classification of trials for BCI feature extraction (Blanchard and Blankertz 2004, Guger et al 2000, Ramoser et al 2000).”
MethodBlankertz, B., Muller, K.-R., Curio, G., Vaughan, T. M., Schalk, G., Wolpaw, J. R., Schlogl, A., Neuper, C., Pfurtscheller, G., Hinterberger, T., et al. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826692 · Cited by 670 · cited 7×
“Other details on the data set can be found in Blankertz et al (2004). The task of the BCI competition 2003 for this data set was to classify the test trials using only the information contained in the training set.”
MethodInfluentialMotor imagery classification by means of source analysis for brain–computer interface applications
Qin, L., Ding, L., & He, B. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/3/002 · Cited by 239
Cited by
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665
Self-citationA review of classification algorithms for EEG-based brain–computer interfaces: A 10 year update
Lotte, F., Bougrain, L., Cichocki, A., Clerc, M., Congedo, M., Rakotomamonjy, A., & Yger, F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab2f2 · Cited by 2,239
Self-citationNoninvasive Brain-Computer Interfaces Based on Sensorimotor Rhythms
He, B., Baxter, B., Edelman, B. J., Cline, C. C., & Ye, W. W. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2407272 · Cited by 233
“[114] attempted to combine these two methods for a two-class MI paradigm”
Detection of self-paced reaching movement intention from EEG signals
Lew, E. (2012) · Frontiers in Neuroengineering · doi:10.3389/fneng.2012.00013 · Cited by 227
“This definition is not to be confused with the work of Congedo et al. (2006), Gonzalez et al. (2006), and Bai et al. (2007) where movement intention was defined as the problem of classifying the intention to move the left hand or right hand.”
Background
Metadata
- Authors
- Congedo, M., Lotte, F., & Lécuyer, A.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2006-03-30
- Volume
- 51
- Issue
- 8
- Pages
- 1971-1989
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1968464138
- Cited by
- 92
- References
- 6
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.