A simulation study on the resolution and sensitivity of magnetic particle imaging
Abstract
This paper presents the first detailed simulation approach to evaluate the proposed imaging method called 'magnetic particle imaging' with respect to resolution and sensitivity. The simulated scanner is large enough to accept human bodies. Together with the choice of field strength and noise the setup is representative for clinical applications. Good resolution, fast image acquisition and high sensitivity are demonstrated for various tracer concentrations, acquisition times, tracer properties and fields of view. Scaling laws for the simple prediction of image quality under the variation of these parameters are derived.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical data and functional relationships in science and technology
Bechmann, R., Hearmon, R. F. S., & Kurtz, S. K. (1969) · Springer eBooks · Cited by 5,858
Tomographic imaging using the nonlinear response of magnetic particles
Gleich, B., & Weizenecker, J. (2005) · Nature · doi:10.1038/nature03808 · Cited by 2,003
Self-citationMacovski, A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360327 · Cited by 420
Röschmann, P. (1987) · Medical Physics · doi:10.1118/1.595995 · Cited by 232
Vlaardingerbroek, M. T., & den Boer, J. A. (2003) · Springer eBooks · doi:10.1007/978-3-662-05252-5 · Cited by 68
Cited by
Biomedical Nanomagnetics: A Spin Through Possibilities in Imaging, Diagnostics, and Therapy
Krishnan, K. M. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2046907 · Cited by 819
Three-dimensional real-time in vivo magnetic particle imaging
Weizenecker, J., Gleich, B., Rahmer, J., Dahnke, H., & Borgert, J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/5/l01 · Cited by 651
Self-citationSignal encoding in magnetic particle imaging: properties of the system function
Rahmer, J., Weizenecker, J., Gleich, B., & Borgert, J. (2009) · BMC Medical Imaging · doi:10.1186/1471-2342-9-4 · Cited by 345
Self-citationMultidimensional X-Space Magnetic Particle Imaging
Goodwill, P. W., & Conolly, S. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2125982 · Cited by 319
Magnetic Particle Imaging (MPI) for NMR and MRI researchers
Saritas, E. U., Goodwill, P. W., Croft, L. R., Konkle, J. J., Lu, K., Zheng, B., & Conolly, S. M. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.11.029 · Cited by 307
Metadata
- Authors
- Weizenecker, J., Borgert, J., & Gleich, B.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2007-10-11
- Volume
- 52
- Issue
- 21
- Pages
- 6363-6374
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2051723824
- Cited by
- 267
- References
- 5
- FWCI
- 8.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.