Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 232

The DOI matches its Crossref record.

Radiofrequency penetration and absorption in the human body: Limitations to high‐field whole‐body nuclear magnetic resonance imaging

Röschmann, P.·1987·Medical Physics

Abstract

This study presents experimental results about the effective depth of penetration and about the radiofrequency (rf) power absorption in humans as a function of frequency. The frequency range investigated covers 10 up to 220 MHz. For the main part, the results were derived from bench measurements of the quality factor Q, and of the resonance frequency shift due to the loading of the coil. Different types of head‐, body‐, and surface coils were investigated loaded with volunteers or metallic phantoms. For spin‐echo imaging at 2 T (85 MHz), the local specific absorption rate (SAR) was found to be ≊0.05 W/kg using a π pulse of 1‐ms duration and pulse repetition time TR =1 s. Measurements of the quality factor Q as a function of frequency show that the SAR depends upon the frequency f according to ∼f 2.15. The effective depth of rf penetration as derived drops from 17 cm at 85 MHz to 7 cm at 220 MHz. Head imaging with B1 penetrating from practically all sides into the object should be possible up to 220 MHz (5 T) with SAR values staying within the local limit of 2 W/kg as set by the FDA. Whole‐body imaging of large subjects as well as surface coil imaging is depth limited above 100‐MHz frequency. Perturbation methods are applied in order to separate the total rf power deposition in the patient into dielectric and magnetic contributions. The observed effects due to interactions of rf magnetic fields with biological tissue contradict predictions based on homogeneous tissue models. A refined tissue model with regions of high electrical conductivity, subdivided by quasi‐insulating adipose layers, provides a rationale for a better understanding of the underlying processes. At frequencies below 100 MHz, the rf power deposition in patients is apparently more evenly distributed over the exposed body volume than currently assumed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.595995

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 232

Metadata

Authors
Röschmann, P.
Venue
Medical Physics
Publisher
Wiley
Published
1987-11
Volume
14
Issue
6
Pages
922-931
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2168965440
Cited by
232
References
0
FWCI
2.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Radiofrequency penetration and absorption in the human body: Limitations to high‐field whole‐body nuclear magnetic resonance imaging. https://app.cochat.ai/papers/10.1118/1.595995
The paper
Röschmann, P. (1987). Radiofrequency penetration and absorption in the human body: Limitations to high‐field whole‐body nuclear magnetic resonance imaging. Medical Physics. https://doi.org/10.1118/1.595995

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.