The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography
Open accessAbstract
Theoretical considerations predicted the feasibility of K-edge x-ray computed tomography (CT) imaging using energy discriminating detectors with more than two energy bins. This technique enables material-specific imaging in CT, which in combination with high-Z element based contrast agents, opens up possibilities for new medical applications. In this paper, we present a CT system with energy detection capabilities, which was used to demonstrate the feasibility of quantitative K-edge CT imaging experimentally. A phantom was imaged containing PMMA, calcium-hydroxyapatite, water and two contrast agents based on iodine and gadolinium, respectively. Separate images of the attenuation by photoelectric absorption and Compton scattering were reconstructed from energy-resolved projection data using maximum-likelihood basis-component decomposition. The data analysis further enabled the display of images of the individual contrast agents and their concentrations, separated from the anatomical background. Measured concentrations of iodine and gadolinium were in good agreement with the actual concentrations. Prior to the tomographic measurements, the detector response functions for monochromatic illumination using synchrotron radiation were determined in the energy range 25 keV-60 keV. These data were used to calibrate the detector and derive a phenomenological model for the detector response and the energy bin sensitivities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simplex Method for Function Minimization
Nelder, J. A., & Mead, R. (1965) · The Computer Journal · doi:10.1093/comjnl/7.4.308 · Cited by 28,905
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Cited by
Atherosclerotic Plaque Composition: Analysis with Multicolor CT and Targeted Gold Nanoparticles
Cormode, D. P., Roessl, E., Thran, A., Skajaa, T., Gordon, R. E., Schlomka, J.-P., Fuster, V., Fisher, E. A., Mulder, W. J. M., Proksa, R., et al. (2010) · Radiology · doi:10.1148/radiol.10092473 · Cited by 479
Self-citationMaterial Separation Using Dual-Energy CT: Current and Emerging Applications
Patino, M., Prochowski, A., Agrawal, M. D., Simeone, F. J., Gupta, R., Hahn, P. F., & Sahani, D. V. (2016) · RadioGraphics · doi:10.1148/rg.2016150220 · Cited by 328
Zheng, B., von See, M. P., Yu, E., Gunel, B., Lu, K., Vazin, T., Schaffer, D. V., Goodwill, P. W., & Conolly, S. M. (2016) · Theranostics · doi:10.7150/thno.13728 · Cited by 322
Engineered nanoparticles for biomolecular imaging
Mahmoudi, M., Serpooshan, V., & Laurent, S. (2011) · Nanoscale · doi:10.1039/c1nr10326a · Cited by 262
Computed Tomography in Color: NanoK‐Enhanced Spectral CT Molecular Imaging
Pan, D., Roessl, E., Schlomka, J., Caruthers, S. D., Senpan, A., Scott, M. J., Allen, J. S., Zhang, H., Hu, G., Gaffney, P. J., et al. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.201005657 · Cited by 178
Self-citation
Metadata
- Authors
- Schlomka, J. P., Roessl, E., Dorscheid, R., Dill, S., Martens, G., Istel, T., Bäumer, C., Herrmann, C., Steadman, R., Zeitler, G., Livne, A., & Proksa, R.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2008-07-08
- Volume
- 53
- Issue
- 15
- Pages
- 4031-4047
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1981418870
- Cited by
- 801
- References
- 2
- FWCI
- 18.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography. https://app.cochat.ai/papers/10.1088/0031-9155/53/15/002
- The paper
- Schlomka, J. P., Roessl, E., Dorscheid, R., Dill, S., Martens, G., Istel, T., Bäumer, C., Herrmann, C., Steadman, R., Zeitler, G., Livne, A., & Proksa, R. (2008). Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/53/15/002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.