A novel, SiPM-array-based, monolithic scintillator detector for PET
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Silicon photomultipliers (SiPMs) are of great interest to positron emission tomography (PET), as they enable new detector geometries, for e.g., depth-of-interaction (DOI) determination, are MR compatible, and offer faster response and higher gain than other solid-state photosensors such as avalanche photodiodes. Here we present a novel detector design with DOI correction, in which a position-sensitive SiPM array is used to read out a monolithic scintillator. Initial characterization of a prototype detector consisting of a 4 x 4 SiPM array coupled to either the front or back surface of a 13.2 mm x 13.2 mm x 10 mm LYSO:Ce(3+) crystal shows that front-side readout results in significantly better performance than conventional back-side readout. Spatial resolutions <1.6 mm full-width-at-half-maximum (FWHM) were measured at the detector centre in response to an approximately 0.54 mm FWHM diameter test beam. Hardly any resolution losses were observed at angles of incidence up to 45 degrees , demonstrating excellent DOI correction. About 14% FWHM energy resolution was obtained. The timing resolution, measured in coincidence with a BaF(2) detector, equals 960 ps FWHM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A combined PET/CT scanner for clinical oncology.
Beyer, T., Townsend, D. W., Brun, T., Kinahan, P. E., Charron, M., Roddy, R., Jerin, J., Young, J., Byars, L. G., & Nutt, R. (2000) · PubMed · Cited by 1,659
Molecular imaging of cancer with positron emission tomography
Gambhir, S. S. (2002) · Nature Reviews Cancer · doi:10.1038/nrc882 · Cited by 1,656
Positron emission tomography provides molecular imaging of biological processes
Phelps, M. E. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.16.9226 · Cited by 1,229
Simultaneous PET-MRI: a new approach for functional and morphological imaging
Judenhofer, M. S., Wehrl, H. F., Newport, D. F., Catana, C., Siegel, S. B., Becker, M., Thielscher, A., Kneilling, M., Lichy, M. P., Eichner, M., et al. (2008) · Nature Medicine · doi:10.1038/nm1700 · Cited by 981
Clinical Applications of PET in Oncology
Rohren, E. M., Turkington, T. G., & Coleman, R. E. (2004) · Radiology · doi:10.1148/radiol.2312021185 · Cited by 859
Surti, S., Kuhn, A., Werner, M. E., Perkins, A. E., Kolthammer, J. A., & Karp, J. S. (2007) · PubMed · Cited by 639
Improvements in cancer staging with PET/CT: literature-based evidence as of September 2006.
Czernin, J. G., Allen-Auerbach, M., & Schelbert, H. R. (2007) · PubMed · Cited by 355
Catana, C., Wu, Y., Judenhofer, M. S., Qi, J., Pichler, B. J., & Cherry, S. R. (2006) · PubMed · Cited by 350
Recent developments in PET detector technology
Lewellen, T. K. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/r01 · Cited by 336
In vivo molecular and genomic imaging: new challenges for imaging physics
Cherry, S. R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/3/r01 · Cited by 334
Muehllehner, G., & Karp, J. S. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r08 · Cited by 288
Multimodality imaging of structure and function
Townsend, D. W. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/4/r01 · Cited by 286
Novel type of avalanche photodetector with Geiger mode operation
Golovin, V., & Saveliev, V. (2004) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2003.11.085 · Cited by 233
Limited Geiger-mode microcell silicon photodiode: new results
Bondarenko, G., Buzhan, P., Dolgoshein, B., Golovin, V, Guschin, E., Ilyin, A., Kaplin, V, Karakash, A., Klanner, R., Pokachalov, V, et al. (2000) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(99)01219-x · Cited by 220
Recent advances and future advances in time-of-flight PET
Moses, W. W. (2007) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2007.06.038 · Cited by 205
Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction
Maas, M. C., Schaart, D. R., van der Laan, D. J., Bruyndonckx, P., Lemaître, C., Beekman, F. J., & van Eijk, C. W. E. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/7/003 · Cited by 148
Self-citationRenker, D. (2006) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2006.10.016 · Cited by 117
Israel, O., & Kuten, A. (2007) · PubMed · Cited by 85
Maas, M. C., van der Laan, D. J., Schaart, D. R., Huizenga, J., Brouwer, J. C., Bruyndonckx, P., Leonard, S., Lemaître, C., & van Eijk, C. W. E. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.873711 · Cited by 78
Self-citationEvaluation of silicon photomultipliers: A promising new detector for MR compatible PET
McElroy, D. P., Saveliev, V. I., Reznik, A., & Rowlands, J. A. (2006) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2006.10.040 · Cited by 63
The Silicon Photomultiplier for application to high-resolution Positron Emission Tomography
Herbert, D., Moehrs, S., D’Ascenzo, N., Belcari, N., Guerra, A. D., Morsani, F., & Saveliev, V. I. (2006) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2006.11.020 · Cited by 53
Characterisation of Geiger-mode avalanche photodiodes for medical imaging applications
Britvitch, I., Johnson, I., Renker, D., Stoykov, A., & Eckart Lorenz, G. (2006) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2006.10.089 · Cited by 37
Study of multi-pixel Geiger-mode avalanche photodiodes as a read-out for PET
Musienko, Y., Auffray, E., Lecoq, P. R., Reucroft, S., Swain, J. D., & Trummer, J. (2006) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2006.10.109 · Cited by 19
Cited by
LaBr3:Ce and SiPMs for time-of-flight PET: achieving 100 ps coincidence resolving time
Schaart, D. R., Seifert, S., Vinke, R., van Dam, H. T., Dendooven, P., Löhner, H., & Beekman, F. J. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/7/n02 · Cited by 225
Self-citationPerformance Evaluation of the Vereos PET/CT System According to the NEMA NU2-2012 Standard
Rausch, I., Ruiz, A., Valverde-Pascual, I., Cal-González, J., Beyer, T., & Carrio, I. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.215541 · Cited by 168
In vivo small animal imaging: Current status and future prospects
Kagadis, G. C., Loudos, G., Katsanos, K., Langer, S. G., & Nikiforidis, G. C. (2010) · Medical Physics · doi:10.1118/1.3515456 · Cited by 164
Krishnamoorthy, S., Blankemeyer, E., Mollet, P., Surti, S., Van Holen, R., & Karp, J. S. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aacec3 · Cited by 141
“…fast scintillator like LSO/LYSO have led to a number of efforts that have revisited monolithic scintillator based PET detector designs in recent years (Joung et al., 2002, Bruyndonckx et al., 2003, Vaska et al., 2004, Maas et al., 2006, Ling et al., 2007, Schaart et al., 2009, Kaul et al., 2013).”
Background
Metadata
- Authors
- Schaart, D. R., van Dam, H. T., Seifert, S., Vinke, R., Dendooven, P., Löhner, H., & Beekman, F. J.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2009-05-15
- Volume
- 54
- Issue
- 11
- Pages
- 3501-3512
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2162266040
- Cited by
- 286
- References
- 23
- FWCI
- 26.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.