The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Positron emission tomography
Open accessAbstract
The developments in positron emission tomography (PET) are reviewed with an emphasis on instrumentation for clinical PET imaging. After a brief summary of positron imaging before the advent of computed tomography, various improvements are highlighted including the move from PET scanners with septa to fully 3D scanners, changes in the preferred scintillators, efforts to improve the energy discrimination, and improvements in attenuation correction. Time-of-flight PET imaging is given special attention due to the recent revival of this technique, which promises significant improvement. Besides technical instrumentation efforts, other factors which influenced the acceptance of clinical PET are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The [18F]fluorodeoxyglucose method for the measurement of local cerebral glucose utilization in man.
Reivich, M., Kuhl, D., Wolf, A., Greenberg, J., Phelps, M., Ido, T., Casella, V, Fowler, J., Hoffman, E., Alavi, A., et al. (1979) · Circulation Research · doi:10.1161/01.res.44.1.127 · Cited by 1,220
Di Chiro, G., DeLaPaz, R. L., Brooks, R. A., Sokoloff, L., Kornblith, P. L., Smith, B. H., Patronas, N. J., Kufta, C. V., Kessler, R. M., Johnston, G. S., et al. (1982) · Neurology · doi:10.1212/wnl.32.12.1323 · Cited by 752
MicroPET: a high resolution PET scanner for imaging small animals
Cherry, S. R., Shao, Y., Silverman, R. W., Meadors, K., Siegel, S., Chatziioannou, A., Young, J. W., Jones, W., Moyers, J. C., Newport, D., et al. (1997) · IEEE Transactions on Nuclear Science · doi:10.1109/23.596981 · Cited by 609
Time of flight in PET revisited
Moses, W. W. (2003) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.817319 · Cited by 336
Physical performance of a positron tomograph for brain imaging with retractable septa
Spinks, T. J., Jones, T., Bailey, D. L., Townsend, D. W., Grootoonk, S., Bloomfield, P. M., Gilardi, M. C., Casey, M. E., Sipe, B., & Reed, J. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/8/002 · Cited by 293
Time-of-flight positron emission tomography: status relative to conventional PET.
Budinger, T. F. (1983) · PubMed · Cited by 283
Molecular imaging of small animals with dedicated PET tomographs
Chatziioannou, A. F. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-001-0683-3 · Cited by 265
Principles of Nuclear Medicine
O'Mara, R. E. (1996) · Archives of Neurology · doi:10.1001/archneur.1996.00550080031008 · Cited by 241
PET performance measurements using the NEMA NU 2-2001 standard.
Daube-Witherspoon, M. E., Karp, J. S., Casey, M., DiFilippo, F. P., Hines, H., Muehllehner, G., Simcic, V. J., Stearns, C. W., Adam, L.-E., Kohlmyer, S. G., et al. (2002) · PubMed · Cited by 222
Self-citationWhole-body positron emission tomography: Part I. Methods and performance characteristics.
Dahlbom, M. L., Hoffman, E. J., Hoh, C. K., Schiepers, C. W., Rosenqvist, G., Hawkins, R. A., & Phelps, M. E. (1992) · PubMed · Cited by 199
Cited by
Focus on time-of-flight PET: the benefits of improved time resolution
Conti, M. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1711-y · Cited by 335
A novel, SiPM-array-based, monolithic scintillator detector for PET
Schaart, D. R., van Dam, H. T., Seifert, S., Vinke, R., Dendooven, P., Löhner, H., & Beekman, F. J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/11/015 · Cited by 286
Li, Y., El Habib Daho, M., Conze, P.-H., Zeghlache, R., Le Boité, H., Tadayoni, R., Cochener, B., Lamard, M., & Quellec, G. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108635 · Cited by 274
State of the art and challenges of time-of-flight PET
Conti, M. (2009) · Physica Medica · doi:10.1016/j.ejmp.2008.10.001 · Cited by 274
Caribé, P. R. R. V., Koole, M., D’Asseler, Y., Van Den Broeck, B., & Vandenberghe, S. (2019) · EJNMMI Physics · doi:10.1186/s40658-019-0264-9 · Cited by 51
Metadata
- Authors
- Muehllehner, G., & Karp, J. S.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2006-06-20
- Volume
- 51
- Issue
- 13
- Pages
- R117-R137
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2120555115
- Cited by
- 288
- References
- 28
- FWCI
- 12.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Positron emission tomography. https://app.cochat.ai/papers/10.1088/0031-9155/51/13/r08
- The paper
- Muehllehner, G., & Karp, J. S. (2006). Positron emission tomography. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/51/13/r08
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.