Abstract
Absorption and emission optical projection tomography (OPT), alternatively referred to as optical computed tomography (optical-CT) and optical-emission computed tomography (optical-ECT), are recently developed three-dimensional imaging techniques with value for developmental biology and ex vivo gene expression studies. The techniques' principles are similar to the ones used for x-ray computed tomography and are based on the approximation of negligible light scattering in optically cleared samples. The optical clearing is achieved by a chemical procedure which aims at substituting the cellular fluids within the sample with a cell membranes' index matching solution. Once cleared the sample presents very low scattering and is then illuminated with a light collimated beam whose intensity is captured in transillumination mode by a CCD camera. Different projection images of the sample are subsequently obtained over a 360 degrees full rotation, and a standard backprojection algorithm can be used in a similar fashion as for x-ray tomography in order to obtain absorption maps. Because not all biological samples present significant absorption contrast, it is not always possible to obtain projections with a good signal-to-noise ratio, a condition necessary to achieve high-quality tomographic reconstructions. Such is the case for example, for early stage's embryos. In this work we demonstrate how, through the use of a random noise removal algorithm, the image quality of the reconstructions can be considerably improved even when the noise is strongly present in the acquired projections. Specifically, we implemented a block matching 3D (BM3D) filter applying it separately on each acquired transillumination projection before performing a complete three-dimensional tomographical reconstruction. To test the efficiency of the adopted filtering scheme, a phantom and a real biological sample were processed. In both cases, the BM3D filter led to a signal-to-noise ratio increment of over 30 dB on severe noise-affected reconstructions revealing original-noise-hidden-image details. These results show the utility of the BM3D approach for OPT under typical conditions of very low light absorption, suggesting its implementation as an efficient alternative to other filtering schemes such as for example the median filter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488 · cited 1×
“While some new techniques such as multiphoton microscopy (Denk et al 1990) or optical coherence tomography (Huang et al 1991) actively or passively reject scattered photons offering therefore higher resolution and better penetration depths, other tomographic methods such as fluorescence molecular…”
MethodImage denoising by sparse 3-D transform-domain collaborative filtering
Dabov, K., Foi, A., Katkovnik, V., & Egiazarian, K. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.901238 · Cited by 9,283
Ideal spatial adaptation by wavelet shrinkage
Donoho, D. L., & Johnstone, I. M. (1994) · Biometrika · doi:10.1093/biomet/81.3.425 · Cited by 8,760 · cited 2×
“Herein we employed a wavelet domain estimation method (Donoho and Johnstone 1994).”
MethodThe Influence Curve and its Role in Robust Estimation
Hampel, F. R. (1974) · Journal of the American Statistical Association · doi:10.1080/01621459.1974.10482962 · Cited by 2,706
Optical Projection Tomography as a Tool for 3D Microscopy and Gene Expression Studies
Sharpe, J., Ahlgren, U., Perry, P., Hill, B., Ross, A., Hecksher-Sørensen, J., Baldock, R., & Davidson, D. (2002) · Science · doi:10.1126/science.1068206 · Cited by 1,158
On the determination of functions from their integral values along certain manifolds
Radon, J. (1986) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1986.4307775 · Cited by 776 · cited 2×
“While x-ray computed tomography (X-CT) implements straight-line integral projections (Radon 1986), FMT and MFT rely instead on diffusive models and depending on the light path shape, the reconstruction algorithms can involve analytical (Davis 1996), iterative (Herman and Lent 1976), deterministic (Roerdink 1998) or st…”
MethodFLUORESCENCE MOLECULAR IMAGING
Ntziachristos, V. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095831 · Cited by 731 · cited 3×
“…offering therefore higher resolution and better penetration depths, other tomographic methods such as fluorescence molecular tomography (FMT) (Ntziachristos 2006) or mesoscopic fluorescence tomography (MFT) (Razansky et al 2009) implement advanced mathematical models oftissue photon…”
BackgroundMethodFrom Local Kernel to Nonlocal Multiple-Model Image Denoising
Katkovnik, V., Foi, A., Egiazarian, K., & Astola, J. (2010) · International Journal of Computer Vision · doi:10.1007/s11263-009-0272-7 · Cited by 353
Some Observations on Robust Estimation
Hogg, R. V. (1967) · Journal of the American Statistical Association · doi:10.1080/01621459.1967.10500924 · Cited by 152
Correction of artefacts in optical projection tomography
Walls, J. R., Sled, J. G., Sharpe, J. A., et al. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/19/015 · Cited by 94
Three-Dimensional Imaging of Drosophila melanogaster
McGurk, L., Morrison, H., Keegan, L. P., Sharpe, J. A., & O’Connell, M. A. (2007) · PLoS ONE · doi:10.1371/journal.pone.0000834 · Cited by 83
Alanentalo, T., Lorén, C. E., Larefalk, Å., Sharpe, J. A., Holmberg, D., & Ahlgren, U. (2008) · Journal of Biomedical Optics · doi:10.1117/1.3000430 · Cited by 51
Three-dimensional imaging of whole rodent organs using optical computed and emission tomography
Oldham, M., Sakhalkar, H. S., Wang, Y. M., Guo, P., Oliver, T. F., Bentley, R. C., Vujašković, Ž., & Dewhirst, M. W. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2709858 · Cited by 38
High throughput transmission optical projection tomography using low cost graphics processing unit
Vinegoni, C., Fexon, L., Feruglio, P. F., Pivovarov, M., Figueiredo, J., Nahrendorf, M., Pozzo, A., Sbarbati, A., & Weissleder, R. (2009) · Optics Express · doi:10.1364/oe.17.022320 · Cited by 30
Self-citationA fast image reconstruction algorithm based on penalized-likelihood estimate
Sheng, J., & Ying, L. (2005) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.02.004 · Cited by 9 · cited 2×
“…integral projections (Radon 1986), FMT and MFT rely instead on diffusive models and depending on the light path shape, the reconstruction algorithms can involve analytical (Davis 1996), iterative (Herman and Lent 1976), deterministic (Roerdink 1998) or stochastic (Sheng and Ying 2005) procedures.”
Method
Cited by
Low-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network
Chen, H., Zhang, Y., Kalra, M. K., Lin, F., Chen, Y., Liao, P., Zhou, J., & Wang, G. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2715284 · Cited by 1,866
Yang, Q., Yan, P., Zhang, Y., Yu, H., Shi, Y., Mou, X., Kalra, M. K., Zhang, Y., Sun, L., & Wang, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2827462 · Cited by 1,630
aLow-dose CT via convolutional neural network
Chen, H., Zhang, Y., Zhang, W., Liao, P., Li, K., Zhou, J., & Wang, G. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.000679 · Cited by 755
You, C., Cong, W., Vannier, M. W., Saha, P. K., Hoffman, E. A., Wang, G., Li, G., Zhang, Y., Zhang, X., Shan, H., et al. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2922960 · Cited by 459
Shan, H., Zhang, Y., Yang, Q., Kruger, U., Kalra, M. K., Sun, L., Cong, W., & Wang, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2832217 · Cited by 411
Metadata
- Authors
- Fumene Feruglio, P., Vinegoni, C., Gros, J., Sbarbati, A., & Weissleder, R.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2010-08-25
- Volume
- 55
- Issue
- 18
- Pages
- 5401-5415
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2041114617
- Cited by
- 175
- References
- 16
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.