Validation of 3D multimodality roadmapping in interventional neuroradiology
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Three-dimensional multimodality roadmapping is entering clinical routine utilization for neuro-vascular treatment. Its purpose is to navigate intra-arterial and intra-venous endovascular devices through complex vascular anatomy by fusing pre-operative computed tomography (CT) or magnetic resonance (MR) with the live fluoroscopy image. The fused image presents the real-time position of the intra-vascular devices together with the patient's 3D vascular morphology and its soft-tissue context. This paper investigates the effectiveness, accuracy, robustness and computation times of the described methods in order to assess their suitability for the intended clinical purpose: accurate interventional navigation. The mutual information-based 3D–3D registration proved to be of sub-voxel accuracy and yielded an average registration error of 0.515 mm and the live machine-based 2D–3D registration delivered an average error of less than 0.2 mm. The capture range of the image-based 3D–3D registration was investigated to characterize its robustness, and yielded an extent of 35 mm and 25° for >80% of the datasets for registration of 3D rotational angiography (3DRA) with CT, and 15 mm and 20° for >80% of the datasets for registration of 3DRA with MR data. The image-based 3D–3D registration could be computed within 8 s, while applying the machine-based 2D–3D registration only took 1.5 µs, which makes them very suitable for interventional use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
McLaughlin, R. A., Hipwell, J., Hawkes, D. J., Noble, J. A., Byrne, J. V., & Cox, T. C. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.852067 · Cited by 63
Cited by
Fully Automatic and Real-Time Catheter Segmentation in X-Ray Fluoroscopy
Ambrosini, P., Ruijters, D., Niessen, W. J., Moelker, A., & van Walsum, T. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-66185-8_65 · Cited by 102
“Therefore, recent approaches for virtual roadmapping that permit the visualization of a 3D vessel tree from pre-operative images have been presented [1, 12].”
BackgroundSelf-citation3D-2D Registration of Cerebral Angiograms: A Method and Evaluation on Clinical Images
Mitrovic, U., Spiclin, Z., Likar, B., & Pernus, F. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2259844 · Cited by 67
“Most calibration-based methods [4], [5] are limited to 3D-DSA to fluoroscopy registrations as they are based on the geometry of a calibrated C-arm X-ray angiography device.”
Fully automated 2D–3D registration and verification
Varnavas, A., Carrell, T., & Penney, G. (2015) · Medical Image Analysis · doi:10.1016/j.media.2015.08.005 · Cited by 50
Metadata
- Authors
- Ruijters, D., Homan, R., Mielekamp, P., van de Haar, P., & Babic, D.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 2011-07-28
- Volume
- 56
- Issue
- 16
- Pages
- 5335-5354
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2070767055
- Cited by
- 48
- References
- 2
- FWCI
- 6.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.