CoChat

Motion in radiotherapy: particle therapy

Bert, C, Durante, M · 2011 · Physics in Medicine and Biology
Cited by 315

The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.

Abstract

Charged particle beam radiotherapy requires dedicated measures to compensate for the dosimetric influence of inter- and intra-fractional target motion. Independent of the delivery technique, these measures have to incorporate the strong influence of the radiological depth on the delivered dose. For scanned beam delivery, interference effects of target motion and scanned beam can further cause under-dosage of the clinical target volume despite using margins. Within the scope of this review, published data with respect to motion management in scattered as well as scanned beam treatment delivery will be summarized. Based on a section covering the dosimetric impact of organ motion, motion management during treatment planning, patient positioning, treatment delivery and treatment validation will be summarized. For scattered beam delivery, the concepts and data are often based on clinical usage since treatment of moving tumors has been performed for several years. In the field of scanned beam delivery, the report focuses on the results of research on countermeasures of the interference effect. Clinical application of these techniques can be expected in the near future.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0031-9155/56/16/r01

Cites

54 of 54 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 315

Metadata

Authors
Bert, C., & Durante, M.
Venue
Physics in Medicine and Biology
Published
2011-07-20
Volume
56
Issue
16
Pages
R113-R144
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W2143101233
Cited by
315
References
54
FWCI
26.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.