Low-dose CT reconstruction via edge-preserving total variation regularization
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
High radiation dose in computed tomography (CT) scans increases the lifetime risk of cancer and has become a major clinical concern. Recently, iterative reconstruction algorithms with total variation (TV) regularization have been developed to reconstruct CT images from highly undersampled data acquired at low mAs levels in order to reduce the imaging dose. Nonetheless, the low-contrast structures tend to be smoothed out by the TV regularization, posing a great challenge for the TV method. To solve this problem, in this work we develop an iterative CT reconstruction algorithm with edge-preserving TV (EPTV) regularization to reconstruct CT images from highly undersampled data obtained at low mAs levels. The CT image is reconstructed by minimizing energy consisting of an EPTV norm and a data fidelity term posed by the x-ray projections. The EPTV term is proposed to preferentially perform smoothing only on the non-edge part of the image in order to better preserve the edges, which is realized by introducing a penalty weight to the original TV norm. During the reconstruction process, the pixels at the edges would be gradually identified and given low penalty weight. Our iterative algorithm is implemented on graphics processing unit to improve its speed. We test our reconstruction algorithm on a digital NURBS-based cardiac-troso phantom, a physical chest phantom and a Catphan phantom. Reconstruction results from a conventional filtered backprojection (FBP) algorithm and a TV regularization method without edge-preserving penalty are also presented for comparison purposes. The experimental results illustrate that both the TV-based algorithm and our EPTV algorithm outperform the conventional FBP algorithm in suppressing the streaking artifacts and image noise under a low-dose context. Our edge-preserving algorithm is superior to the TV-based algorithm in that it can preserve more information of low-contrast structures and therefore maintain acceptable spatial resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,591
Nonlinear total variation based noise removal algorithms
Rudin, L. I., Osher, S., & Fatemi, E. (1992) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(92)90242-f · Cited by 15,704
Methods of conjugate gradients for solving linear systems
Hestenes, M. R., & Stiefel, E. (1952) · Journal of Research of the National Bureau of Standards · doi:10.6028/jres.049.044 · Cited by 8,132
Nonlinear programming: theory and algorithms
(1993) · Computers & Operations Research · doi:10.1016/0305-0548(93)90042-h · Cited by 5,779
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
Signal Recovery by Proximal Forward-Backward Splitting
Combettes, P. L., & Wajs, V. R. (2005) · Multiscale Modeling & Simulation · doi:10.1137/050626090 · Cited by 2,678
Smith-Bindman, R. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.427 · Cited by 2,464
Nonlinear Programming: Theory and Algorithms
Bazaraa, M. S., Sherali, H. D., & Shetty, C. M. (2006) · Wiley eBooks · doi:10.1002/0471787779 · Cited by 2,369
The Radon Transform and Some of Its Applications
Deans, S. R. (1983) · Cited by 2,055
Sidky, E. Y., & Pan, X. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/021 · Cited by 1,995
Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007
Berrington de González, A. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.440 · Cited by 1,888
The Shannon sampling theorem—Its various extensions and applications: A tutorial review
Jerri, A. J. (1977) · Proceedings of the IEEE · doi:10.1109/proc.1977.10771 · Cited by 1,749
Fast calculation of the exact radiological path for a three‐dimensional CT array
Siddon, R. L. (1985) · Medical Physics · doi:10.1118/1.595715 · Cited by 1,535
Design of an image edge detection filter using the Sobel operator
Kanopoulos, N., Vasanthavada, N., & Baker, R. L. (1988) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.996 · Cited by 1,212
Chen, G.-H., Tang, J., & Leng, S. (2008) · Medical Physics · doi:10.1118/1.2836423 · Cited by 1,141
Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT
Sidky, E. Y., Kao, C.-M., & Pan, X. (2006) · Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics · doi:10.3233/xst-2006-00155 · Cited by 1,091
Cancer risks from diagnostic radiology
HALL, E. J., & BRENNER, D. J. (2008) · The British Journal of Radiology · doi:10.1259/bjr/01948454 · Cited by 915
Fixed-Point Continuation for $\ell_1$-Minimization: Methodology and Convergence
Hale, E. T., Yin, W., & Zhang, Y. (2008) · SIAM Journal on Optimization · doi:10.1137/070698920 · Cited by 909
Ecient Sparse Matrix-Vector Multiplication on CUDA
Bell, N., & Garland, M. (2008) · Cited by 689
Radiation Risk to Children From Computed Tomography
Brody, A. S., Frush, D. P., Huda, W., Brent, R. L., & Radiology, A. T. S. O. (2007) · Pediatrics · doi:10.1542/peds.2007-1910 · Cited by 606
Accelerating popular tomographic reconstruction algorithms on commodity PC graphics hardware
Xu, F., & Mueller, K. (2005) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2005.851398 · Cited by 252
Implementation and evaluation of various demons deformable image registration algorithms on a GPU
Gu, X., Pan, H., Liang, Y., Castillo, R., Yang, D., Choi, D., Castillo, E., Majumdar, A., Guerrero, T., & Jiang, S. B. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/1/012 · Cited by 243
Self-citationJia, X., Lou, Y., Li, R., Song, W. Y., & Jiang, S. B. (2010) · Medical Physics · doi:10.1118/1.3371691 · Cited by 232
Self-citationReal-time 3D computed tomographic reconstruction using commodity graphics hardware
Xu, F., & Mueller, K. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/12/006 · Cited by 223
Dual-Energy CT: Clinical Applications in Various Pulmonary Diseases
Kang, M.-J., Park, C. M., Lee, C.-H., Goo, J. M., & Lee, H. J. (2010) · RadioGraphics · doi:10.1148/rg.303095101 · Cited by 192
Sharp, G. C., Kandasamy, N., Singh, H., & Folkert, M. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/19/003 · Cited by 190
Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro‐CT
Song, J., Liu, Q. H., Johnson, G. A., & Badea, C. T. (2007) · Medical Physics · doi:10.1118/1.2795830 · Cited by 183
Development of a GPU-based Monte Carlo dose calculation code for coupled electron–photon transport
Jia, X., Gu, X., Sempau, J., Choi, D., Majumdar, A., & Jiang, S. B. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/11/006 · Cited by 151
Self-citationChodick, G., Ronckers, C. M., Shalev, V., & Ron, E. (2007) · PubMed · Cited by 148
Fast cone-beam CT image reconstruction using GPU hardware
Yan, G., Tian, J., Zhu, S., Dai, Y., & Qin, C. (2008) · Journal of X-Ray Science and Technology · doi:10.3233/xst-2008-00205 · Cited by 129
Samant, S. S., Xia, J., Muyan-Özçelik, P., & Owens, J. D. (2008) · Medical Physics · doi:10.1118/1.2948318 · Cited by 119
GPU-based ultrafast IMRT plan optimization
Men, C., Gu, X., Choi, D., Majumdar, A., Zheng, Z., Mueller, K. D., & Jiang, S. B. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/21/008 · Cited by 115
Self-citationGPU-based ultra-fast dose calculation using a finite pencil beam model
Gu, X., Choi, D., Men, C., Pan, H. Y., Majumdar, A., & Jiang, S. B. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/20/017 · Cited by 86
Self-citationGPU-based ultra-fast direct aperture optimization for online adaptive radiation therapy
Men, C., Jia, X., & Jiang, S. B. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/15/008 · Cited by 85
Self-citationEdgeCS: edge guided compressive sensing reconstruction
Guo, W., & Yin, W. (2010) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.863354 · Cited by 59
Fast convolution‐superposition dose calculation on graphics hardware
Hissoiny, S., Ozell, B., & Després, P. (2009) · Medical Physics · doi:10.1118/1.3120286 · Cited by 58
Learning Effective Parameter Settings for Iterative CT Reconstruction Algorithms
Xu, W., & Mueller, K. D. (2009) · Cited by 10
Cited by
Yang, Q., Yan, P., Zhang, Y., Yu, H., Shi, Y., Mou, X., Kalra, M. K., Zhang, Y., Sun, L., & Wang, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2827462 · Cited by 1,630
Iterative reconstruction methods in X-ray CT
Beister, M., Kolditz, D., & Kalender, W. A. (2012) · Physica Medica · doi:10.1016/j.ejmp.2012.01.003 · Cited by 751
Medical image processing on the GPU – Past, present and future
Eklund, A., Dufort, P., Forsberg, D., & LaConte, S. M. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.05.008 · Cited by 397
Sharpness-Aware Low-Dose CT Denoising Using Conditional Generative Adversarial Network
Yi, X., & Babyn, P. (2018) · Journal of Digital Imaging · doi:10.1007/s10278-018-0056-0 · Cited by 343
Liu, Y., Ma, J., Fan, Y., & Liang, Z. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/23/7923 · Cited by 335
Metadata
- Authors
- Tian, Z., Jia, X., Yuan, K., Pan, T., & Jiang, S. B.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2011-08-22
- Volume
- 56
- Issue
- 18
- Pages
- 5949-5967
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2119259145
- Cited by
- 396
- References
- 38
- FWCI
- 12.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›