CoChat

GPU-based fast Monte Carlo simulation for radiotherapy dose calculation

Open access
Jia, Xun, Gu, Xuejun, Graves, Yan Jiang, Folkerts, Michael, Jiang, Steve B · 2011 · Physics in Medicine and Biology
Cited by 185

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

Monte Carlo (MC) simulation is commonly considered to be the most accurate dose calculation method in radiotherapy. However, its efficiency still requires improvement for many routine clinical applications. In this paper, we present our recent progress toward the development of a graphics processing unit (GPU)-based MC dose calculation package, gDPM v2.0. It utilizes the parallel computation ability of a GPU to achieve high efficiency, while maintaining the same particle transport physics as in the original dose planning method (DPM) code and hence the same level of simulation accuracy. In GPU computing, divergence of execution paths between threads can considerably reduce the efficiency. Since photons and electrons undergo different physics and hence attain different execution paths, we use a simulation scheme where photon transport and electron transport are separated to partially relieve the thread divergence issue. A high-performance random number generator and a hardware linear interpolation are also utilized. We have also developed various components to handle the fluence map and linac geometry, so that gDPM can be used to compute dose distributions for realistic IMRT or VMAT treatment plans. Our gDPM package is tested for its accuracy and efficiency in both phantoms and realistic patient cases. In all cases, the average relative uncertainties are less than 1%. A statistical t-test is performed and the dose difference between the CPU and the GPU results is not found to be statistically significant in over 96% of the high dose region and over 97% of the entire region. Speed-up factors of 69.1 ∼ 87.2 have been observed using an NVIDIA Tesla C2050 GPU card against a 2.27 GHz Intel Xeon CPU processor. For realistic IMRT and VMAT plans, MC dose calculation can be completed with less than 1% standard deviation in 36.1 ∼ 39.6 s using gDPM.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0031-9155/56/22/002

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

  • GPU-based fast Monte Carlo dose calculation for proton therapy

    Jia, X., Schümann, J., Paganetti, H., & Jiang, S. B. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/23/7783 · Cited by 177

    “…computational perspective, it is not straightforward to achieve high performance in MC particle transport on a GPU platform (Hissoiny et al 2011, Jia et al 2011, Pratx and Xing 2011) because of the inherent conflict between the GPU’s SIMD (single instruction multiple data) processing scheme and…”
    BackgroundMethodInfluentialSelf-citation

See all 185

Metadata

Authors
Jia, X., Gu, X., Graves, Y. J., Folkerts, M., & Jiang, S. B.
Venue
Physics in Medicine and Biology
Published
2011-10-21
Volume
56
Issue
22
Pages
7017-7031
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W2137920044
Cited by
185
References
28
FWCI
12.79
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: GPU-based fast Monte Carlo simulation for radiotherapy dose calculation. https://app.cochat.ai/papers/10.1088/0031-9155/56/22/002
The paper
Jia, X., Gu, X., Graves, Y. J., Folkerts, M., & Jiang, S. B. (2011). GPU-based fast Monte Carlo simulation for radiotherapy dose calculation. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/56/22/002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.