GPU-based fast Monte Carlo dose calculation for proton therapy
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Accurate radiation dose calculation is essential for successful proton radiotherapy. Monte Carlo (MC) simulation is considered to be the most accurate method. However, the long computation time limits it from routine clinical applications. Recently, graphics processing units (GPUs) have been widely used to accelerate computationally intensive tasks in radiotherapy. We have developed a fast MC dose calculation package, gPMC, for proton dose calculation on a GPU. In gPMC, proton transport is modeled by the class II condensed history simulation scheme with a continuous slowing down approximation. Ionization, elastic and inelastic proton nucleus interactions are considered. Energy straggling and multiple scattering are modeled. Secondary electrons are not transported and their energies are locally deposited. After an inelastic nuclear interaction event, a variety of products are generated using an empirical model. Among them, charged nuclear fragments are terminated with energy locally deposited. Secondary protons are stored in a stack and transported after finishing transport of the primary protons, while secondary neutral particles are neglected. gPMC is implemented on the GPU under the CUDA platform. We have validated gPMC using the TOPAS/Geant4 MC code as the gold standard. For various cases including homogeneous and inhomogeneous phantoms as well as a patient case, good agreements between gPMC and TOPAS/Geant4 are observed. The gamma passing rate for the 2%/2 mm criterion is over 98.7% in the region with dose greater than 10% maximum dose in all cases, excluding low-density air regions. With gPMC it takes only 6-22 s to simulate 10 million source protons to achieve ∼1% relative statistical uncertainty, depending on the phantoms and energy. This is an extremely high efficiency compared to the computational time of tens of CPU hours for TOPAS/Geant4. Our fast GPU-based code can thus facilitate the routine use of MC dose calculation in proton therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106 · cited 9×
“Simulations in various phantom cases and in a patient case indicate that gPMC leads to dose calculation results that are in good agreement with that of TOPAS, which is based on the popular Geant4 code.”
MethodInfluentialEidelman, S., Hayes, K. G., Olive, K. A., Aguilar-Benitez, M., Amsler, C., Asner, D., Babu, K. S., Barnett, R. M., Beringer, J., Burchat, P. R., et al. (2004) · Physics Letters B · doi:10.1016/j.physletb.2004.06.001 · Cited by 6,673
Particle Data Group, Workman, R. L., Burkert, V. D., Crede, V, Klempt, E., Thoma, U., Tiator, L., Agashe, K., Aielli, G., Allanach, B. C., et al. (2022) · Progress of Theoretical and Experimental Physics · doi:10.1093/ptep/ptac097 · Cited by 5,964
Yost, G. P., Barnett, R. M., Hinchliffe, I., Lynch, G. R., Rittenberg, A., Ross, R. R., Suzuki, M., Trippe, T. G., Wohl, C. G., Armstrong, B., et al. (1988) · Physics Letters B · doi:10.1016/0370-2693(88)90505-9 · Cited by 4,399
Hagiwara, K., Hikasa, K., Nakamura, K., Tanabashi, M., Aguilar-Benitez, M., Amsler, C., Barnett, R. M., Burchat, P. R., Carone, C. D., Caso, C., et al. (2002) · Physical Review D · doi:10.1103/physrevd.66.010001 · Cited by 3,099
A technique for the quantitative evaluation of dose distributions
Low, D. A., Harms, W. B., Mutic, S., & Purdy, J. A. (1998) · Medical Physics · doi:10.1118/1.598248 · Cited by 2,880 · cited 1×
“The results are quantitatively measured using a γ -test (Low et al 1998).”
MethodRelative biological effectiveness (RBE) values for proton beam therapy
Paganetti, H., Niemierko, A., Ancukiewicz, M., Gerweck, L. E., Goitein, M., Loeffler, J. S., & Suit, H. D. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02754-2 · Cited by 1,364
Self-citationRange uncertainties in proton therapy and the role of Monte Carlo simulations
Paganetti, H. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/11/r99 · Cited by 1,325 · cited 1×
“Consequently, Monte Carlo (MC) dose calculation is desirable and it has been demonstrated that the use of MC in proton therapy could lead to a significant reduction in treatment planning margins (Paganetti 2012).”
MethodSelf-citationPENELOPE: A code system for Monte Carlo simulation of electron and photon transport
(2020) · Penelope · doi:10.1787/9d2cc3d5-en · Cited by 1,275
TOPAS: An innovative proton Monte Carlo platform for research and clinical applications
Perl, J., Shin, J., Schümann, J., Faddegon, B., & Paganetti, H. (2012) · Medical Physics · doi:10.1118/1.4758060 · Cited by 1,140 · cited 15×
“We then measure the agreements between the gPMC result and the TOPAS result using a γ -test.”
MethodInfluentialSelf-citation
Cited by
Newhauser, W. D., & Zhang, R. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/8/r155 · Cited by 675
Nuclear physics in particle therapy: a review
Durante, M., & Paganetti, H. (2016) · Reports on Progress in Physics · doi:10.1088/0034-4885/79/9/096702 · Cited by 345
Self-citation
Metadata
- Authors
- Jia, X., Schümann, J., Paganetti, H., & Jiang, S. B.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-11-06
- Volume
- 57
- Issue
- 23
- Pages
- 7783-7797
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2015290878
- Cited by
- 177
- References
- 39
- FWCI
- 10.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: GPU-based fast Monte Carlo dose calculation for proton therapy. https://app.cochat.ai/papers/10.1088/0031-9155/57/23/7783
- The paper
- Jia, X., Schümann, J., Paganetti, H., & Jiang, S. B. (2012). GPU-based fast Monte Carlo dose calculation for proton therapy. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/57/23/7783
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.