The DOI matches its Crossref record.
Range uncertainties in proton therapy and the role of Monte Carlo simulations
Open accessAbstract
The main advantages of proton therapy are the reduced total energy deposited in the patient as compared to photon techniques and the finite range of the proton beam. The latter adds an additional degree of freedom to treatment planning. The range in tissue is associated with considerable uncertainties caused by imaging, patient setup, beam delivery and dose calculation. Reducing the uncertainties would allow a reduction of the treatment volume and thus allow a better utilization of the advantages of protons. This paper summarizes the role of Monte Carlo simulations when aiming at a reduction of range uncertainties in proton therapy. Differences in dose calculation when comparing Monte Carlo with analytical algorithms are analyzed as well as range uncertainties due to material constants and CT conversion. Range uncertainties due to biological effects and the role of Monte Carlo for in vivo range verification are discussed. Furthermore, the current range uncertainty recipes used at several proton therapy facilities are revisited. We conclude that a significant impact of Monte Carlo dose calculation can be expected in complex geometries where local range uncertainties due to multiple Coulomb scattering will reduce the accuracy of analytical algorithms. In these cases Monte Carlo techniques might reduce the range uncertainty by several mm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Paganetti, H. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/22/r419 · Cited by 915
Self-citationContemporary radiotherapy: present and future
Chandra, R. A., Keane, F. K., Voncken, F. E. M., & Thomas, C. R. (2021) · The Lancet · doi:10.1016/s0140-6736(21)00233-6 · Cited by 380
All the fun of the FAIR: fundamental physics at the facility for antiproton and ion research
Durante, M., Indelicato, P., Jonson, B., Koch, V, Langanke, K., Meißner, U.-G., Nappi, E., Nilsson, T., Stöhlker, T., Widmann, E., et al. (2019) · Physica Scripta · doi:10.1088/1402-4896/aaf93f · Cited by 129
Outcomes of proton therapy for patients with functional pituitary adenomas
Wattson, D. A., Tanguturi, S. K., Spiegel, D. Y., Niemierko, A., Biller, B. M. K., Nachtigall, L. B., Bussière, M. R., Swearingen, B., Chapman, P. H., Loeffler, J. S., et al. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.06.068 · Cited by 125
Applied nuclear physics at the new high-energy particle accelerator facilities
Durante, M., Golubev, A., Park, W.-Y., & Trautmann, C. (2019) · Physics Reports · doi:10.1016/j.physrep.2019.01.004 · Cited by 72
Metadata
- Authors
- Paganetti, H.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-05-09
- Volume
- 57
- Issue
- 11
- Pages
- R99-R117
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1999189079
- Cited by
- 1,325
- References
- 0
- FWCI
- 45.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Range uncertainties in proton therapy and the role of Monte Carlo simulations. https://app.cochat.ai/papers/10.1088/0031-9155/57/11/r99
- The paper
- Paganetti, H. (2012). Range uncertainties in proton therapy and the role of Monte Carlo simulations. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/57/11/r99
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.