Range uncertainties in proton therapy and the role of Monte Carlo simulations
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
The main advantages of proton therapy are the reduced total energy deposited in the patient as compared to photon techniques and the finite range of the proton beam. The latter adds an additional degree of freedom to treatment planning. The range in tissue is associated with considerable uncertainties caused by imaging, patient setup, beam delivery and dose calculation. Reducing the uncertainties would allow a reduction of the treatment volume and thus allow a better utilization of the advantages of protons. This paper summarizes the role of Monte Carlo simulations when aiming at a reduction of range uncertainties in proton therapy. Differences in dose calculation when comparing Monte Carlo with analytical algorithms are analyzed as well as range uncertainties due to material constants and CT conversion. Range uncertainties due to biological effects and the role of Monte Carlo for in vivo range verification are discussed. Furthermore, the current range uncertainty recipes used at several proton therapy facilities are revisited. We conclude that a significant impact of Monte Carlo dose calculation can be expected in complex geometries where local range uncertainties due to multiple Coulomb scattering will reduce the accuracy of analytical algorithms. In these cases Monte Carlo techniques might reduce the range uncertainty by several mm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106
FLUKA: A Multi-Particle Transport Code
Ferrari, A., Sala, P. R., Fasso, A., & Ranft, J. (2005) · doi:10.2172/877507 · Cited by 2,536
Radiological Use of Fast Protons
Wilson, R. R. (1946) · Radiology · doi:10.1148/47.5.487 · Cited by 1,403
Relative biological effectiveness (RBE) values for proton beam therapy
Paganetti, H., Niemierko, A., Ancukiewicz, M., Gerweck, L. E., Goitein, M., Loeffler, J. S., & Suit, H. D. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02754-2 · Cited by 1,364
Self-citationTOPAS: An innovative proton Monte Carlo platform for research and clinical applications
Perl, J., Shin, J., Schümann, J., Faddegon, B., & Paganetti, H. (2012) · Medical Physics · doi:10.1118/1.4758060 · Cited by 1,140
Self-citationThe calibration of CT Hounsfield units for radiotherapy treatment planning
Schneider, U., Pedroni, E., & Lomax, A. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/009 · Cited by 1,093
Tissue Substitutes in Radiation Dosimetry and Measurement
Cloutier, R. J. (1989) · Radiation Research · doi:10.2307/3577533 · Cited by 1,076
Schneider, W., Bortfeld, T., & Schlegel, W. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/314 · Cited by 831
Comments on ICRU Report No. 49: Stopping Powers and Ranges for Protons and Alpha Particles
Ziegler, J. F. (1999) · Radiation Research · doi:10.2307/3580097 · Cited by 616
Theoretical and experimental aspects of the energy loss of relativistic heavily ionizing particles
Ahlen, S. P. (1980) · Reviews of Modern Physics · doi:10.1103/revmodphys.52.121 · Cited by 583
Cited by
TOPAS: An innovative proton Monte Carlo platform for research and clinical applications
Perl, J., Shin, J., Schümann, J., Faddegon, B., & Paganetti, H. (2012) · Medical Physics · doi:10.1118/1.4758060 · Cited by 1,140
Self-citationPaganetti, H. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/22/r419 · Cited by 915
Self-citationImage-guided radiotherapy: from current concept to future perspectives
Jaffray, D. A. (2012) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2012.194 · Cited by 496
Contemporary radiotherapy: present and future
Chandra, R. A., Keane, F. K., Voncken, F. E. M., & Thomas, C. R. (2021) · The Lancet · doi:10.1016/s0140-6736(21)00233-6 · Cited by 380
Nuclear physics in particle therapy: a review
Durante, M., & Paganetti, H. (2016) · Reports on Progress in Physics · doi:10.1088/0034-4885/79/9/096702 · Cited by 345
Self-citationPaganetti, H., Blakely, E., Carabe‐Fernandez, A., Carlson, D. J., Das, I. J., Dong, L., Grosshans, D., Held, K. D., Mohan, R., Moiseenko, V., et al. (2019) · Medical Physics · doi:10.1002/mp.13390 · Cited by 310
Self-citationTommasino, F., & Durante, M. (2015) · Cancers · doi:10.3390/cancers7010353 · Cited by 252
Deep learning based synthetic‐CT generation in radiotherapy and PET: A review
Spadea, M. F., Maspero, M., Zaffino, P., & Seco, J. (2021) · Medical Physics · doi:10.1002/mp.15150 · Cited by 201
Online proton therapy monitoring: clinical test of a Silicon-photodetector-based in-beam PET
Ferrero, V., Fiorina, E., Morrocchi, M., Pennazio, F., Baroni, G., Battistoni, G., Belcari, N., Camarlinghi, N., Ciocca, M., Del Guerra, A., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-22325-6 · Cited by 197
GPU-based fast Monte Carlo dose calculation for proton therapy
Jia, X., Schümann, J., Paganetti, H., & Jiang, S. B. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/23/7783 · Cited by 177
“Consequently, Monte Carlo (MC) dose calculation is desirable and it has been demonstrated that the use of MC in proton therapy could lead to a significant reduction in treatment planning margins (Paganetti 2012).”
MethodSelf-citationRoadmap: proton therapy physics and biology
Paganetti, H., Beltran, C., Both, S., Dong, L., Flanz, J., Furutani, K., Grassberger, C., Grosshans, D. R., Knopf, A.-C., Langendijk, J. A., et al. (2021) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abcd16 · Cited by 175
“In the community, such an approach is estimated to have an uncertainty of±3%–3.5% (Paganetti 2012), although this will be lower inmost soft-tissues, whilst being somewhat higher in some forms of hard bone.”
BackgroundInfluentialSelf-citationPhysics and biomedical challenges of cancer therapy with accelerated heavy ions
Durante, M., Debus, J., & Loeffler, J. S. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00368-5 · Cited by 170
All the fun of the FAIR: fundamental physics at the facility for antiproton and ion research
Durante, M., Indelicato, P., Jonson, B., Koch, V, Langanke, K., Meißner, U.-G., Nappi, E., Nilsson, T., Stöhlker, T., Widmann, E., et al. (2019) · Physica Scripta · doi:10.1088/1402-4896/aaf93f · Cited by 129
Outcomes of proton therapy for patients with functional pituitary adenomas
Wattson, D. A., Tanguturi, S. K., Spiegel, D. Y., Niemierko, A., Biller, B. M. K., Nachtigall, L. B., Bussière, M. R., Swearingen, B., Chapman, P. H., Loeffler, J. S., et al. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.06.068 · Cited by 125
“Total patients by adenoma type 165 CD 79 (48%) NS 10 (6%) GH 61 (37%) PRL 12 (7%) TSH 3 (2%) Sex Female 109 (66%) Male 56 (34%) Median age at proton irradiation, y (range) 43 (12-84) Median transsphenoidal surgical procedures (range) 1 (0-4)”
BackgroundMethodApplied nuclear physics at the new high-energy particle accelerator facilities
Durante, M., Golubev, A., Park, W.-Y., & Trautmann, C. (2019) · Physics Reports · doi:10.1016/j.physrep.2019.01.004 · Cited by 72
Sangwan, N., & Kumar, A. (2022) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2021.110068 · Cited by 4
Metadata
- Authors
- Paganetti, H.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-05-09
- Volume
- 57
- Issue
- 11
- Pages
- R99-R117
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1999189079
- Cited by
- 1,325
- References
- 23
- FWCI
- 45.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.