Fast multigrid-based computation of the induced electric field for transcranial magnetic stimulation
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
In transcranial magnetic stimulation (TMS), the distribution of the induced electric field, and the affected brain areas, depends on the position of the stimulation coil and the individual geometry of the head and brain. The distribution of the induced electric field in realistic anatomies can be modelled using computational methods. However, existing computational methods for accurately determining the induced electric field in realistic anatomical models have suffered from long computation times, typically in the range of tens of minutes or longer. This paper presents a matrix-free implementation of the finite-element method with a geometric multigrid method that can potentially reduce the computation time to several seconds or less even when using an ordinary computer. The performance of the method is studied by computing the induced electric field in two anatomically realistic models. An idealized two-loop coil is used as the stimulating coil. Multiple computational grid resolutions ranging from 2 to 0.25 mm are used. The results show that, for macroscopic modelling of the electric field in an anatomically realistic model, computational grid resolutions of 1 mm or 2 mm appear to provide good numerical accuracy compared to higher resolutions. The multigrid iteration typically converges in less than ten iterations independent of the grid resolution. Even without parallelization, each iteration takes about 1.0 s or 0.1 s for the 1 and 2 mm resolutions, respectively. This suggests that calculating the electric field with sufficient accuracy in real time is feasible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
Christ, A., Kainz, W., Hahn, E. G., Honegger, K., Zefferer, M., Neufeld, E., Rascher, W., Janka, R., Bautz, W., Chen, J., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/n01 · Cited by 1,439 · cited 1×
“The TMS-induced electric fields are determined in Caucasian male (DUKE) and female (ELLA) models (Christ et al 2010). Originally, the models comprise surface representation of tissues that has been constructed from MR images of a 34-year-old Caucasian male and a 26-year-old Caucasian female. The same models have been…”
MethodDeng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2013) · Brain Stimulation · doi:10.1016/j.brs.2012.02.005 · Cited by 1,073
Windhoff, M., Opitz, A., & Thielscher, A. (2013) · Human Brain Mapping · doi:10.1002/hbm.21479 · Cited by 441
Impact of the gyral geometry on the electric field induced by transcranial magnetic stimulation
Thielscher, A., Opitz, A., & Windhoff, M. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.061 · Cited by 439
Spatiotemporal dynamics of continuum neural fields
Bressloff, P. C. (2012) · Journal of Physics A: Mathematical and Theoretical · doi:10.1088/1751-8113/45/3/033001 · Cited by 414
How the brain tissue shapes the electric field induced by transcranial magnetic stimulation
Opitz, A., Windhoff, M., Heidemann, R. M., Turner, R., & Thielscher, A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.069 · Cited by 360
Thielscher, A., & Kammer, T. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.02.019 · Cited by 294 · cited 1×
“Realistic TMS coils can be modelled using combinations of hundreds of infinitesimally short magnetic dipoles (Ravazzani et al 1996, Thielscher and Kammer 2002, 2004) or 3D models of coil wires (Salinas et al 2007, Bijsterbosch et al 2012). Since the purpose of this work is not to investigate the effects of coil design…”
MethodNumerical Solution of Partial Differential Equations on Parallel Computers
(2006) · Lecture Notes in Computational Science and Engineering · doi:10.1007/3-540-31619-1 · Cited by 236
Güllmar, D., Haueisen, J., & Reichenbach, J. R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.02.014 · Cited by 214
Thielscher, A., & Kammer, T. (2002) · NeuroImage · doi:10.1006/nimg.2002.1282 · Cited by 206
Molecular modeling of protein materials: case study of elastin
Tarakanova, A., & Buehler, M. J. (2013) · Modelling and Simulation in Materials Science and Engineering · doi:10.1088/0965-0393/21/6/063001 · Cited by 160
High-resolution organ dosimetry for human exposure to low-frequency magnetic fields
Dawson, T. W., & Stuchly, M. A. (1998) · IEEE Transactions on Magnetics · doi:10.1109/20.668071 · Cited by 140
Detailed 3D models of the induced electric field of transcranial magnetic stimulation coils
Salinas, F. S., Lancaster, J. L., & Fox, P. T. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/10/016 · Cited by 132
Bijsterbosch, J. D., Barker, A. T., Lee, K.-H., & Woodruff, P. W. R. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0922-8 · Cited by 130
Salinas, F. S., Lancaster, J. L., & Fox, P. T. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/12/002 · Cited by 130 · cited 1×
“Several recent studies have investigated the induced electric field in realistic models of the head and brain using computational techniques (Chen and Mogul 2010, Opitz et al 2011, Thielscher et al 2011, Sekino et al 2006, Salinas et al 2009, De Geeter et al 2011, Bijsterbosch et al 2012).”
MethodReducing the staircasing error in computational dosimetry of low-frequency electromagnetic fields
Laakso, I., & Hirata, A. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/4/n25 · Cited by 122
Self-citationRavazzani, P., Ruohonen, J., Grandori, F., & Tognola, G. (1996) · Annals of Biomedical Engineering · doi:10.1007/bf02684229 · Cited by 102
Geeter, N. D., Crevecoeur, G., & Dupré, L. R. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2087758 · Cited by 36
Chen, M., & Mogul, D. J. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2037493 · Cited by 33
Computational analysis of thresholds for magnetophosphenes
Laakso, I., & Hirata, A. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/19/6147 · Cited by 26
Self-citation
Cited by
Inter-subject Variability in Electric Fields of Motor Cortical tDCS
Laakso, I., Tanaka, S., Koyama, S., De Santis, V., & Hirata, A. (2015) · Brain Stimulation · doi:10.1016/j.brs.2015.05.002 · Cited by 372
Self-citationEffects of coil orientation on the electric field induced by TMS over the hand motor area
Laakso, I., Hirata, A., & Ugawa, Y. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/1/203 · Cited by 174
Self-citationLaakso, I., Mikkonen, M., Koyama, S., Hirata, A., & Tanaka, S. (2019) · Scientific Reports · doi:10.1038/s41598-018-37226-x · Cited by 171
Self-citation
Metadata
- Authors
- Laakso, I., & Hirata, A.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-11-06
- Volume
- 57
- Issue
- 23
- Pages
- 7753-7765
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2095116161
- Cited by
- 174
- References
- 21
- FWCI
- 3.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.