The DOI matches its Crossref record.
Enhanced proton treatment in mouse tumors through proton irradiated nanoradiator effects on metallic nanoparticles
Abstract
The impact of protons on metallic nanoparticles (MNPs) produces the potent release of MNP-induced secondary electrons and characteristic x-rays. To determine the ability of secondary radiations to enhance proton treatment, the therapeutic irradiation of tumors was investigated in mice receiving 100-300 mg MNPs/kg intravenously prior to single dose, 10-41 Gy, proton irradiation. A proton beam was utilized to irradiate nanoparticles with a single Bragg peak set to occur inside a tumor volume (fully absorbed) or to occur after the beam had traversed the entire body. The dose-dependent increase in complete tumor regression (CTR) was 37-62% in the fully-absorbed irradiation group or 50-100% in the traversing irradiation group, respectively, compared with the proton-alone control mice (p < 0.01). One year survival was 58-100% versus 11-13% proton alone. The dose-dependent increase of intracellular reactive oxygen species level was 12-36% at 10 Gy compared with the proton-alone control cell. Therapeutic effective drug concentration that led to 100% CTR with a proton dose of 31 Gy was measured either 41 µg Au/g tissue or 59 µg Fe/g tissue. MNP-based proton treatment increased not only percent CTR and survival in vivo but also ROS generation in vitro, suggesting tumor dose enhancement from secondary radiation as one potent pathway of therapeutic enhancement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gold nanoparticles for applications in cancer radiotherapy: Mechanisms and recent advancements
Her, S., Jaffray, D. A., & Allen, C. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.12.012 · Cited by 865
Roadmap to Clinical Use of Gold Nanoparticles for Radiation Sensitization
Schuemann, J., Berbeco, R., Chithrani, D. B., Cho, S. H., Kumar, R., McMahon, S. J., Sridhar, S., & Krishnan, S. (2016) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.09.032 · Cited by 253
Cui, L., Her, S., Dunne, M., Borst, G. R., De Souza, R., Bristow, R. G., Jaffray, D. A., & Allen, C. (2017) · Radiation Research · doi:10.1667/rr14578.1 · Cited by 58
Enhancing Proton Therapy Efficacy Through Nanoparticle-Mediated Radiosensitization
Ma, J., Shen, H., & Mi, Z. (2024) · Cells · doi:10.3390/cells13221841 · Cited by 23
Metadata
- Authors
- Kim, J.-K., Seo, S.-J., Kim, H.-T., Kim, K.-H., Chung, M.-H., Kim, K.-R., & Ye, S.-J.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-11-30
- Volume
- 57
- Issue
- 24
- Pages
- 8309-8323
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1970875160
- Cited by
- 168
- References
- 0
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced proton treatment in mouse tumors through proton irradiated nanoradiator effects on metallic nanoparticles. https://app.cochat.ai/papers/10.1088/0031-9155/57/24/8309
- The paper
- Kim, J.-K., Seo, S.-J., Kim, H.-T., Kim, K.-H., Chung, M.-H., Kim, K.-R., & Ye, S.-J. (2012). Enhanced proton treatment in mouse tumors through proton irradiated nanoradiator effects on metallic nanoparticles. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/57/24/8309
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.