Multi-sensor magnetoencephalography with atomic magnetometers
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The authors have detected magnetic fields from the human brain with two independent, simultaneously operating rubidium spin-exchange-relaxation-free magnetometers. Evoked responses from auditory stimulation were recorded from multiple subjects with two multi-channel magnetometers located on opposite sides of the head. Signal processing techniques enabled by multi-channel measurements were used to improve signal quality. This is the first demonstration of multi-sensor atomic magnetometer magnetoencephalography and provides a framework for developing a non-cryogenic, whole-head magnetoencephalography array for source localization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 3×
“The resulting signal-to-noise improvement is apparent in figures 4(b) and 4(c), where a clear M100 auditory evoked response is seen on the signal-space projected data approximately 90 ms after the presented stimuli, consistent with a typical M100 response (Hämäläinen et al 1993).”
BackgroundMethodA subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631 · cited 2×
“0031-9155/13/176065+13$33.00 © 2013 Institute of Physics and Engineering in Medicine Printed in the UK & the USA 6065 Over the past decade, AM technology has advanced into the sub-fT sensitivity range (Kominis et al 2003) with a record sensitivity of 0.2 fT/ √ Hz (Dang et al 2010).”
BackgroundInfluentialHigh-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049 · cited 2×
“The general theory of operation of SERF magnetometers has been detailed previously (Allred et al 2002, Ledbetter et al 2008), and the specific implementation used in our sensor has also been discussed in considerable depth (Johnson and Schwindt 2010, Johnson et al 2010).”
BackgroundMethodUltrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
Dang, H. B., Maloof, A. C., & Romalis, M. V. (2010) · Applied Physics Letters · doi:10.1063/1.3491215 · Cited by 891 · cited 2×
“0031-9155/13/176065+13$33.00 © 2013 Institute of Physics and Engineering in Medicine Printed in the UK & the USA 6065 Over the past decade, AM technology has advanced into the sub-fT sensitivity range (Kominis et al 2003) with a record sensitivity of 0.2 fT/ √ Hz (Dang et al 2010).”
BackgroundInfluentialSuppression of Interference and Artifacts by the Signal Space Separation Method
Taulu, S., Kajola, M., & Simola, J. (2004) · Brain Topography · doi:10.1023/b:brat.0000032864.93890.f9 · Cited by 541
Unshielded three-axis vector operation of a spin-exchange-relaxation-free atomic magnetometer
Seltzer, S. J., & Romalis, M. V. (2004) · Applied Physics Letters · doi:10.1063/1.1814434 · Cited by 320 · cited 1×
“A well-documented zeroing procedure (Seltzer and Romalis 2004, Wyllie et al 2012a) is used to determine the required currents.”
MethodBiomagnetism using SQUIDs: status and perspectives
Sternickel, K., & Braginski, A. I. (2006) · Superconductor Science and Technology · doi:10.1088/0953-2048/19/3/024 · Cited by 180 · cited 1×
“For the past several decades, scientific and clinical advances in biomagnetism have been achieved predominantly using superconducting quantum interference device (SQUID) magnetometers and gradiometers (Sternickel and Braginski 2006).”
BackgroundDynamical mapping of the human cardiomagnetic field with a room-temperature, laser-optical sensor
Bison, G., Wynands, R., & Weis, A. (2003) · Optics Express · doi:10.1364/oe.11.000904 · Cited by 100
Cited by
Moving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377
Boto, E., Meyer, S. S., Shah, V., Alem, O., Knappe, S., Kruger, P., Fromhold, T. M., Lim, M., Glover, P. M., Morris, P. G., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.034 · Cited by 471
“Other groups have shown how sensors positioned over the occipital lobe enabled detection of the induced changes in alpha (8–13 Hz) rhythm by opening and closing the eyes (Kamada et al., 2015; Sander et al., 2012).”
BackgroundQuantum metrology and its application in biology
Taylor, M. A., & Bowen, W. P. (2016) · Physics Reports · doi:10.1016/j.physrep.2015.12.002 · Cited by 470
Brookes, M. J., Leggett, J., Rea, M., Hill, R. M., Holmes, N., Boto, E., & Bowtell, R. (2022) · Trends in Neurosciences · doi:10.1016/j.tins.2022.05.008 · Cited by 412
Optically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography
Tierney, T. M., Holmes, N., Mellor, S., López, J. D., Roberts, G., Hill, R. M., Boto, E., Leggett, J., Shah, V., Brookes, M. J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.063 · Cited by 400
Metadata
- Authors
- Johnson, C. N., Schwindt, P. D. D., & Weisend, M.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2013-08-12
- Volume
- 58
- Issue
- 17
- Pages
- 6065-6077
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2034978403
- Cited by
- 131
- References
- 8
- FWCI
- 5.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.