Abstract
Ultrasound (US) is a widely used clinical imaging modality that offers penetration depths in tissue of >10 cm. However, the spatial resolution in US imaging is fundamentally limited by diffraction to approximately half the wavelength of the sound wave employed. The spatial resolution of optical microscopy is limited by the same fundamental physics, but in recent years super-resolution imaging techniques have been developed that overcome the diffraction limit through the localization of many spatially separated photo-switchable or photo-activatable fluorophores. In this paper, we apply a related approach to demonstrate super-resolution imaging with US. We imaged dilute suspensions of microbubble contrast agents flowing through narrow tube-based phantoms. By spatially localizing multiple spatially isolated microbubbles, we constructed super-resolved microbubble location density maps that clearly resolve features 5.1-2.2 times smaller than the US system point spread function full width half maximum in the lateral and axial directions respectively. Our initial characterization experiment using a fixed 100 µm diameter brass wire and a US frequency of 2 MHz suggests that for an ideal stationary point scatterer the ultimate resolution of the unmodified clinical US system used could be in the range of 2-4 µm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Threshold Selection Method from Gray-Level Histograms
Otsu, N. (1979) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1979.4310076 · Cited by 43,398
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Super-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657 · cited 1×
“In practice background and read-out noise reduce the precision, however, accuracies are typically in the range of tens of nanometres, i.e. ∼20-fold smaller than the diffraction limit (Huang et al 2009).”
BackgroundMulticolor Super-Resolution Imaging with Photo-Switchable Fluorescent Probes
Bates, M., Huang, B., Dempsey, G. T., & Zhuang, X. (2007) · Science · doi:10.1126/science.1146598 · Cited by 1,504
Diagnostic Ultrasound Imaging: Inside Out
(2014) · Elsevier eBooks · doi:10.1016/c2011-0-07261-7 · Cited by 1,093
Diagnostic ultrasound Imaging : Inside out
(2005) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-2005-861725 · Cited by 761
Kuenen, M. P. J., Saidov, T. A., Wijkstra, H., & Mischi, M. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2013.03.004 · Cited by 93
Cited by
Ultrafast ultrasound localization microscopy for deep super-resolution vascular imaging
Errico, C., Pierre, J., Pezet, S., Desailly, Y., Lenkei, Z., Couture, O., & Tanter, M. (2015) · Nature · doi:10.1038/nature16066 · Cited by 1,349
Super-resolution Ultrasound Imaging
Christensen-Jeffries, K., Couture, O., Dayton, P. A., Eldar, Y. C., Hynynen, K., Kiessling, F., O'Reilly, M., Pinton, G. F., Schmitz, G., Tang, M.-X., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.11.013 · Cited by 558
Self-citationUltrasound Localization Microscopy and Super-Resolution: A State of the Art
Couture, O., Hingot, V., Heiles, B., Muleki-Seya, P., & Tanter, M. (2018) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2018.2850811 · Cited by 423
Transcranial ultrafast ultrasound localization microscopy of brain vasculature in patients
Demené, C., Robin, J., Dizeux, A., Heiles, B., Pernot, M., Tanter, M., & Perren, F. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00697-x · Cited by 370
A Review of Acoustic Impedance Matching Techniques for Piezoelectric Sensors and Transducers
Rathod, V. T. (2020) · Sensors · doi:10.3390/s20144051 · Cited by 328
Metadata
- Authors
- Viessmann, O. M., Eckersley, R. J., Christensen-Jeffries, K., Tang, M. X., & Dunsby, C.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2013-09-02
- Volume
- 58
- Issue
- 18
- Pages
- 6447-6458
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2068166000
- Cited by
- 277
- References
- 7
- FWCI
- 3.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.