In vivo evaluation of the elastic anisotropy of the human Achilles tendon using shear wave dispersion analysis
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Non-invasive evaluation of the Achilles tendon elastic properties may enhance diagnosis of tendon injury and the assessment of recovery treatments. Shear wave elastography has shown to be a powerful tool to estimate tissue mechanical properties. However, its applicability to quantitatively evaluate tendon stiffness is limited by the understanding of the physics on the shear wave propagation in such a complex medium. First, tendon tissue is transverse isotropic. Second, tendons are characterized by a marked stiffness in the 400 to 1300 kPa range (i.e. fast shear waves). Hence, the shear wavelengths are greater than the tendon thickness leading to guided wave propagation. Thus, to better understand shear wave propagation in tendons and consequently to properly estimate its mechanical properties, a dispersion analysis is required. In this study, shear wave velocity dispersion was measured in vivo in ten Achilles tendons parallel and perpendicular to the tendon fibre orientation. By modelling the tendon as a transverse isotropic viscoelastic plate immersed in fluid it was possible to fully describe the experimental data (deviation<1.4%). We show that parallel to fibres the shear wave velocity dispersion is not influenced by viscosity, while it is perpendicularly to fibres. Elasticity (found to be in the range from 473 to 1537 kPa) and viscosity (found to be in the range from 1.7 to 4 Pa.s) values were retrieved from the model in good agreement with reported results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,476 · cited 3×
“Recently, Aubry et al (2013) observed anisotropy by applying the supersonic shear imaging (SSI) technique (Bercoff et al 2004) in vivo to human Achilles tendons.”
BackgroundMethodSelf-citationShear wave elasticity imaging: a new ultrasonic technology of medical diagnostics
Sarvazyan, A. P., Rudenko, O. V., Swanson, S. D., Fowlkes, J. B., & Emelianov, S. Y. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00110-0 · Cited by 1,727 · cited 1×
“Shear wave elastography (Bercoff et al 2004, Chen et al 2004, Nightingale et al 2002, Sandrin et al 2002, Catheline et al 1999, Sarvazyan et al 1998) has shown to be a powerful tool to estimate the mechanical properties of tissue.”
MethodAcoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility
Nightingale, K., Soo, M. S., Nightingale, R., & Trahey, G. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00499-9 · Cited by 1,108 · cited 1×
“Shear wave elastography (Bercoff et al 2004, Chen et al 2004, Nightingale et al 2002, Sandrin et al 2002, Catheline et al 1999, Sarvazyan et al 1998) has shown to be a powerful tool to estimate the mechanical properties of tissue.”
MethodMatrix techniques for modeling ultrasonic waves in multilayered media
Lowe, M. J. S. (1995) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.393096 · Cited by 1,029 · cited 4×
“Thus, the displacement field in the surrounding fluid may be described as (Lowe 1995, Nenadic et al 2011): UF1 = ±kLAF± ei(±kLx1+kx3−ωt) (11) UF3 = kAF± ei(±kLx1+kx3−ωt) (12) where kL = [(ω/cL)2 − k2]1/2, cL stands for the speed of sound in the fluid and again the + and − signs correspond to a wave…”
BackgroundMethodInfluentialHistopathology of Common Tendinopathies: Update and Implications for Clinical Management
Khan, K. M., Cook, J. L., Bonar, F., Harcourt, P., & ??strom, M. (1999) · Sports Medicine · doi:10.2165/00007256-199927060-00004 · Cited by 982
Berg, W. A., Cosgrove, D. O., Doré, C. J., Schäfer, F. K. W., Svensson, W. E., Hooley, R. J., Ohlinger, R., Mendelson, E. B., Balu-Maestro, C., Locatelli, M., et al. (2012) · Radiology · doi:10.1148/radiol.11110640 · Cited by 845
Tanter, M., Bercoff, J., Athanasiou, A., Deffieux, T., Gennisson, J.-L., Montaldo, G., Muller, M., Tardivon, A., & Fink, M. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.02.002 · Cited by 733 · cited 3×
“The effect of curvature in the data analysis consists in whether curvature should be taken into account to correct the wave propagation distance (Tanter et al 2009, Nenadic et al 2013). In the experiments presented in this study, no curved wave propagation was observed. Furthermore, such curvature correction is not ne…”
MethodInfluentialSelf-citationGennisson, J.-L., Deffieux, T., Macé, E., Montaldo, G., Fink, M., & Tanter, M. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.02.013 · Cited by 683 · cited 3×
“Nevertheless, it is important to point out that the viscosity values obtained in this work are consistent with the ones reported for other tissue such as muscle (Gennisson et al 2010).”
MethodResultSelf-citationQuantifying Hepatic Shear Modulus In Vivo Using Acoustic Radiation Force
Palmeri, M. L., Wang, M. H., Dahl, J. J., Frinkley, K. D., & Nightingale, K. R. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.10.009 · Cited by 683
Cited by
Elastography for Muscle Biomechanics: Toward the Estimation of Individual Muscle Force
Hug, F., Tucker, K., Gennisson, J.-L., Tanter, M., & Nordez, A. (2015) · Exercise and Sport Sciences Reviews · doi:10.1249/jes.0000000000000049 · Cited by 342
Self-citationAubry, S., Nueffer, J.-P., Tanter, M., Becce, F., Vidal, C., & Michel, F. (2015) · Radiology · doi:10.1148/radiol.14140434 · Cited by 187
Self-citationGauging force by tapping tendons
Martin, J. A., Brandon, S. C. E., Keuler, E. M., Hermus, J. R., Ehlers, A. C., Segalman, D. J., Allen, M. S., & Thelen, D. G. (2018) · Nature Communications · doi:10.1038/s41467-018-03797-6 · Cited by 186
Prado-Costa, R., Rebelo, J., Monteiro-Barroso, J., & Preto, A. S. (2018) · Insights into Imaging · doi:10.1007/s13244-018-0642-1 · Cited by 186
Spatial variations in Achilles tendon shear wave speed
DeWall, R. J., Slane, L. C., Lee, K. S., & Thelen, D. G. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.05.008 · Cited by 105
“Shear wave speed in the free Achilles tendon has been measured (Arda et al., 2011; Aubry et al., 2013; Brum et al., 2014; Chen et al., 2013; Hug et al., 2013) and has been shown to increase as the tendon is stretched (Aubry et al.”
InfluentialElastography imaging: the 30 year perspective
Ormachea, J., & Parker, K. J. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abca00 · Cited by 104
“Although it was not the main purpose of the study, SWD was also used to measure Achilles tendon viscosity in the orientation perpendicular to the tendon fiber by fitting the leaky Lamb wave equation and assuming a Voigt model by Brum et al (2014).”
BackgroundMethodDeep learning in ultrasound elastography imaging: A review
Li, H., Bhatt, M., Qu, Z., Zhang, S., Hartel, M. C., Khademhosseini, A., & Cloutier, G. (2022) · Medical Physics · doi:10.1002/mp.15856 · Cited by 47
Metadata
- Authors
- Brum, J., Bernal, M., Gennisson, J. L., & Tanter, M.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2014-01-17
- Volume
- 59
- Issue
- 3
- Pages
- 505-523
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2158331324
- Cited by
- 190
- References
- 35
- FWCI
- 14.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.