Radiotherapy planning using MRI
Open accessThe DOI matches its Crossref record; 101 of the 101 references it cites were found in a registry or an index.
Abstract
The use of magnetic resonance imaging (MRI) in radiotherapy (RT) planning is rapidly expanding. We review the wide range of image contrast mechanisms available to MRI and the way they are exploited for RT planning. However a number of challenges are also considered: the requirements that MR images are acquired in the RT treatment position, that they are geometrically accurate, that effects of patient motion during the scan are minimized, that tissue markers are clearly demonstrated, that an estimate of electron density can be obtained. These issues are discussed in detail, prior to the consideration of a number of specific clinical applications. This is followed by a brief discussion on the development of real-time MRI-guided RT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952 · cited 1×
“The recent advent of parallel imaging and sparse sampling techniques has allowed faster data acquisition, and it is now possible to acquire volumetric data with high temporal resolution (Lustig et al 2007, Lustig and Pauly 2010).”
BackgroundPrinciples of Nuclear Magnetic Resonance Microscopy
Callaghan, P. T. (1991) · doi:10.1093/oso/9780198539445.001.0001 · Cited by 3,599
Increase in signal-to-noise ratio of > 10,000 times in liquid-state NMR
Ardenkjær-Larsen, J. H., Fridlund, B., Gram, A., Hansson, G., Hansson, L., Lerche, M. H., Servin, R., Thaning, M., & Golman, K. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1733835100 · Cited by 2,861
ESUR prostate MR guidelines 2012
Barentsz, J. O., Richenberg, J., Clements, R., Choyke, P., Verma, S., Villeirs, G., Rouviere, O., Logager, V., & Fütterer, J. J. (2012) · European Radiology · doi:10.1007/s00330-011-2377-y · Cited by 2,438
Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and Recommendations
Padhani, A. R., Liu, G., Mu-Koh, D., Chenevert, T. L., Thoeny, H. C., Takahara, T., Dzik-Jurasz, A., Ross, B. D., Van Cauteren, M., Collins, D., et al. (2009) · Neoplasia · doi:10.1593/neo.81328 · Cited by 1,989
Tofts, P. S., & Kermode, A. G. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170208 · Cited by 1,456
Seppenwoolde, Y., Shirato, H., Kitamura, K., Shimizu, S., van Herk, M., Lebesque, J. V., & Miyasaka, K. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02803-1 · Cited by 1,379
Metabolic Imaging of Patients with Prostate Cancer Using Hyperpolarized [1- 13 C]Pyruvate
Nelson, S. J., Kurhanewicz, J., Vigneron, D. B., Larson, P. E. Z., Harzstark, A. L., Ferrone, M., van Criekinge, M., Chang, J. W., Bok, R., Park, I., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3006070 · Cited by 1,286
Jovicich, J., Czanner, S., Greve, D., Haley, E., van der Kouwe, A., Gollub, R., Kennedy, D., Schmitt, F., Brown, G., MacFall, J., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.09.046 · Cited by 1,265
Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner
Delso, G., Fürst, S., Jakoby, B., Ladebeck, R., Ganter, C., Nekolla, S. G., Schwaiger, M., & Ziegler, S. I. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092726 · Cited by 874
Smith, B. D., Arthur, D. W., Buchholz, T. A., Haffty, B. G., Hahn, C. A., Hardenbergh, P. H., Julian, T. B., Marks, L. B., Todor, D. A., Vicini, F. A., et al. (2009) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.02.031 · Cited by 872
Choline metabolism in malignant transformation
Glunde, K., Bhujwalla, Z. M., & Ronen, S. M. (2011) · Nature Reviews Cancer · doi:10.1038/nrc3162 · Cited by 823
SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐space
Lustig, M., & Pauly, J. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22428 · Cited by 822
McRobbie, D. W., Moore, E. A., Graves, M. J., & Prince, M. R. (2017) · Cambridge University Press eBooks · doi:10.1017/9781107706958 · Cited by 752
Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging
Robson, M. D., Gatehouse, P. D., Bydder, M., & Bydder, G. M. (2003) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200311000-00001 · Cited by 717
Hambrock, T., Somford, D. M., Huisman, H. J., van Oort, I. M., Witjes, J. A., Hulsbergen-van de Kaa, C. A., Scheenen, T., & Barentsz, J. O. (2011) · Radiology · doi:10.1148/radiol.11091409 · Cited by 572
Definition of the prostate in CT and MRI: a multi-observer study
Rasch, C., Barillot, I., Remeijer, P., Touw, A., van Herk, M., & Lebesque, J. V. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(98)00351-4 · Cited by 565
Metal-Induced Artifacts in MRI
Hargreaves, B. A., Worters, P. W., Pauly, K. B., Pauly, J. M., Koch, K. M., & Gold, G. E. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.11.7364 · Cited by 559 · cited 1×
“However, the field inhomogeneity associated with common orthopaedic implants has been shown to be orders of magnitude higher than the naturally occurring field inhomogeneity in biological material (Hargreaves et al 2011).”
BackgroundFütterer, J. J., Heijmink, S. W. T. P. J., Scheenen, T. W. J., Veltman, J., Huisman, H. J., Vos, P., de Kaa, C. A. H., Witjes, J. A., Krabbe, P. F. M., Heerschap, A., et al. (2006) · Radiology · doi:10.1148/radiol.2412051866 · Cited by 559
Howe, F. A., Barton, S. J., Cudlip, S. A., Stubbs, M., Saunders, D. E., Murphy, M., Wilkins, P., Opstad, K. S., Doyle, V. L., McLean, M. A., et al. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10367 · Cited by 539
Lagendijk, J. J. W., Raaymakers, B. W., Raaijmakers, A. J. E., Overweg, J., Brown, K. J., Kerkhof, E. M., van der Put, R. W., Hårdemark, B., van Vulpen, M., & van der Heide, U. A. (2008) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2007.10.034 · Cited by 511
Diffusion MRI: Theory, methods, and applications
Jones, D. K. (2011) · Cited by 444
Dimopoulos, J. C. A., Petrow, P., Tanderup, K., Petric, P., Berger, D., Kirisits, C., Pedersen, E. M., van Limbergen, E., Haie-Meder, C., & Pötter, R. (2012) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2011.12.024 · Cited by 440
A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities
Chang, H., & Fitzpatrick, J. M. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.158935 · Cited by 425
In Vivo NMR Spectroscopy: Principles and Techniques
de Graaf, R. A. (2007) · Wiley eBooks · doi:10.1002/9780470512968 · Cited by 409
SEMAC: Slice encoding for metal artifact correction in MRI
Lu, W., Pauly, K. B., Gold, G. E., Pauly, J. M., & Hargreaves, B. A. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21967 · Cited by 392
Quantitative MRI of the Brain: Measuring Changes Caused by Disease
(2003) · Wiley eBooks · doi:10.1002/0470869526 · Cited by 347
Fallone, B. G., Murray, B., Rathee, S., Stanescu, T., Steciw, S., Vidakovic, S., Blosser, E., & Tymofichuk, D. (2009) · Medical Physics · doi:10.1118/1.3125662 · Cited by 325
Johansson, A., Karlsson, M., & Nyholm, T. (2011) · Medical Physics · doi:10.1118/1.3578928 · Cited by 324
4D MR imaging of respiratory organ motion and its variability
Siebenthal, M. V., Székely, G., Gamper, U., Boesiger, P., Lomax, A., & Cattin, P. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/6/001 · Cited by 324
Minniti, G., Amelio, D., Amichetti, M., Salvati, M., Muni, R., Bozzao, A., Lanzetta, G., Scarpino, S., Arcella, A., & Enrici, R. M. (2010) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2010.08.020 · Cited by 323
Magnetic Resonance Imaging in Active Surveillance of Prostate Cancer: A Systematic Review
Schoots, I. G., Petrides, N., Giganti, F., Bokhorst, L. P., Rannikko, A., Klotz, L., Villers, A., Hugosson, J., & Moore, C. M. (2015) · European Urology · doi:10.1016/j.eururo.2014.10.050 · Cited by 315
Dowling, J. A., Lambert, J., Parker, J., Salvado, O., Fripp, J., Capp, A., Wratten, C., Denham, J. W., & Greer, P. B. (2012) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2011.11.056 · Cited by 314
MR image artifacts from periodic motion
Wood, M. L., & Henkelman, R. M. (1985) · Medical Physics · doi:10.1118/1.595782 · Cited by 302
Overview of Dynamic Contrast-Enhanced MRI in Prostate Cancer Diagnosis and Management
Verma, S., Turkbey, B., Muradyan, N., Rajesh, A., Cornud, F., Haider, M. A., Choyke, P. L., & Harisinghani, M. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.12.8510 · Cited by 301
A Model-Based Method for Retrospective Correction of Geometric Distortions in Diffusion-Weighted EPI
Andersson, J. L. R., & Skare, S. (2002) · NeuroImage · doi:10.1006/nimg.2001.1039 · Cited by 274
A multispectral three‐dimensional acquisition technique for imaging near metal implants
Koch, K. M., Lorbiecki, J. E., Hinks, R. S., & King, K. F. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21856 · Cited by 269
Houssami, N., & Hayes, D. F. (2009) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.20028 · Cited by 267
New Fibrate Use and Acute Renal Outcomes in Elderly Adults: A Population-Based Study
Zhao, Y. Y., Weir, M. A., Manno, M., Cordy, P., Gomes, T., Hackam, D. G., Juurlink, D. N., Mamdani, M., Moist, L., Parikh, C. R., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-156-8-201204170-00401 · Cited by 258
Tamada, T., Sone, T., Jo, Y., Toshimitsu, S., Yamashita, T., Yamamoto, A., Tanimoto, D., & Ito, K. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21503 · Cited by 258
Imaging near metal with a MAVRIC‐SEMAC hybrid
Koch, K. M., Brau, A. C., Chen, W., Gold, G. E., Hargreaves, B. A., Koff, M., McKinnon, G. C., Potter, H. G., & King, K. F. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22523 · Cited by 230
Radiotherapy treatment planning of prostate cancer using magnetic resonance imaging alone
Lee, Y. (2003) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(02)00440-1 · Cited by 227
Plewes, D. B., & Kucharczyk, W. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23642 · Cited by 220
An Evaluation of the Use of Magnetic Field Maps to Undistort Echo-Planar Images
Cusack, R., Brett, M., & Osswald, K. (2003) · NeuroImage · doi:10.1006/nimg.2002.1281 · Cited by 219
Magnetic resonance angiography: current status and future directions
Hartung, M. P., Grist, T. M., & François, C. J. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-19 · Cited by 213
Lagendijk, J. J. W., Raaymakers, B. W., Van den Berg, C. A. T., Moerland, M. A., Philippens, M. E., & van Vulpen, M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/21/r349 · Cited by 206
Stadlbauer, A., Ganslandt, O., Buslei, R., Hammen, T., Gruber, S., Moser, E., Buchfelder, M., Salomonowitz, E., & Nimsky, C. (2006) · Radiology · doi:10.1148/radiol.2403050937 · Cited by 200
Morgan, P. S., Bowtell, R. W., McIntyre, D. J. O., & Worthington, B. S. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20032 · Cited by 188
Uh, J., Merchant, T. E., Li, Y., Li, X., & Hua, C. (2014) · Medical Physics · doi:10.1118/1.4873315 · Cited by 187
In vivo molecular imaging for planning radiation therapy of gliomas: An application of 1H MRSI
Nelson, S. J., Graves, E., Pirzkall, A., Li, X., Antiniw Chan, A., Vigneron, D. B., & McKnight, T. R. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10183 · Cited by 179
Nichol, A. M., Brock, K. K., Lockwood, G. A., Moseley, D. J., Rosewall, T., Warde, P. R., Catton, C. N., & Jaffray, D. A. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.08.021 · Cited by 176
Functional magnetic resonance imaging
Ogawa, S., & Sung, Y.-W. (2007) · Scholarpedia · doi:10.4249/scholarpedia.3105 · Cited by 172
Statistical Analysis of fMRI Data
Ashby, F. G. (2011) · The MIT Press eBooks · doi:10.7551/mitpress/8764.001.0001 · Cited by 158
Padhani, A. R., MacVicar, A. D., Gapinski, C. J., Dearnaley, D. P., Parker, G. J. M., John Suckling, A., Leach, M. O., & Husband, J. E. (2001) · Radiology · doi:10.1148/radiology.218.2.r01ja04365 · Cited by 155
Statistical Analysis of fMRI Data
Ashby, F. G. (2019) · The MIT Press eBooks · doi:10.7551/mitpress/11557.001.0001 · Cited by 140
Application of superparamagnetic iron oxide to imaging of hepatocellular carcinoma
Tanimoto, A., & Kuribayashi, S. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2005.11.040 · Cited by 133
Willats, L., & Calamante, F. (2012) · NMR in Biomedicine · doi:10.1002/nbm.2833 · Cited by 130
Blackall, J. M., Ahmad, S., Miquel, M. E., McClelland, J. R., Landau, D., & Hawkes, D. J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/17/003 · Cited by 130
van den Bergh, R. C. N., Ahmed, H. U., Bangma, C. H., Cooperberg, M. R., Villers, A. A., & Parker, C. C. (2014) · European Urology · doi:10.1016/j.eururo.2014.01.027 · Cited by 125
Boosting imaging defined dominant prostatic tumors: A systematic review
Bauman, G. S., Haider, M. A., van der Heide, U. A., & Ménard, C. M. (2013) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2013.04.027 · Cited by 115
Jiang, J., Wu, Y., Huang, M., Yang, W., Chen, W., & Feng, Q. (2013) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2013.05.007 · Cited by 109
Reduction of blurring in view angle tilting MRI
Butts, K., Pauly, J. M., & Gold, G. E. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20375 · Cited by 108
Glunde, K., Jiang, L., Moestue, S. A., & Gribbestad, I. S. (2011) · NMR in Biomedicine · doi:10.1002/nbm.1751 · Cited by 107
Reinsberg, S. A., Doran, S., Charles-Edwards, E., & Leach, M. O. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/11/014 · Cited by 103
Correction of geometric distortion in fMRI data
Jezzard, P. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.010 · Cited by 102
Dose Prescription and Dose-Volume Effects in Radiosurgery
Flíckinger, J. C., Lunsford, L. D., & Kondziolka, D. S. (1992) · Neurosurgery Clinics of North America · doi:10.1016/s1042-3680(18)30682-x · Cited by 94
Harnan, S., Cooper, K. L., Meng, Y., Ward, S. E., Fitzgerald, P., Papaioannou, D. E., Ingram, C., Lorenz, E., Wilkinson, I. D., & Wyld, L. (2011) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2011.07.007 · Cited by 91
d’Arcy, J. A., Collins, D. J., Padhani, A. R., Walker‐Samuel, S., Suckling, J., & Leach, M. O. (2006) · Radiographics · doi:10.1148/rg.262045187 · Cited by 88
Multiparametric MRI of Rectal Cancer in the Assessment of Response to Therapy: A Systematic Review
Hötker, A. M., García‐Aguilar, J., & Gollub, M. J. (2014) · Diseases of the Colon & Rectum · doi:10.1097/dcr.0000000000000127 · Cited by 87
Grimsby, G. M., Gray, R. J., Dueck, A. C., Carpenter, S. G., Stucky, C.-C., Aspey, H., Giurescu, M. E., & Pockaj, B. A. (2009) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2009.07.012 · Cited by 84
Caramanos, Z., Fonov, V., Francis, S. J., Narayanan, S., Pike, G. B., Collins, D. L., & Arnold, D. L. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.08.008 · Cited by 82
Wang, P., Popovtzer, A., Eisbruch, A., & Cao, Y. (2012) · Medical Physics · doi:10.1118/1.4737022 · Cited by 76
Functional imaging in adult and paediatric brain tumours
Peet, A. C., Arvanitis, T. N., Leach, M. O., & Waldman, A. D. (2012) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2012.187 · Cited by 74
Singh, A. K., Guion, P., Crouse, N. S., Ullman, K., Smith, S., Albert, P. S., Gabor Fichtinger, A., Choyke, P. L., Xu, S., Kruecker, J., et al. (2007) · Radiation Oncology · doi:10.1186/1748-717x-2-36 · Cited by 74
Attenuation correction for PET/MR: Problems, novel approaches and practical solutions
Martínez-Möller, A., & Nekolla, S. G. (2012) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2012.08.003 · Cited by 63
Tumor bed delineation for external beam accelerated partial breast irradiation: A systematic review
Yang, J. T., Tao, R., Elkhuizen, P. H. M., van Vliet-Vroegindeweij, C., Li, G., & Powell, S. N. (2013) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2013.05.028 · Cited by 62
Geometric Distortion in Structural Magnetic Resonance Imaging
Wang, D., & Doddrell, D. M. (2005) · Current Medical Imaging Formerly Current Medical Imaging Reviews · doi:10.2174/1573405052953029 · Cited by 62
Advanced imaging applied to radiotherapy planning in head and neck cancer: a clinical review
Newbold, K. L., Partridge, M., Cook, G., Sohaib, S. A., Charles-Edwards, E., Rhys‐Evans, P., Harrington, K. J., & Nutting, C. M. (2006) · British Journal of Radiology · doi:10.1259/bjr/48822193 · Cited by 59
Perfusion MRI Using Dynamic-Susceptibility Contrast MRI: Quantification Issues in Patient Studies
Calamante, F. (2010) · Topics in Magnetic Resonance Imaging · doi:10.1097/rmr.0b013e31821e53f5 · Cited by 56
Brændengen, M., Hansson, K., Radu, C., Siegbahn, A., Jacobsson, H., & Glimelius, B. L. G. (2011) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2011.03.031 · Cited by 54
Schmitz, A. C., van den Bosch, M. A. A. J., Loo, C. E., Mali, W. P. T. M., Bartelink, H. G. M. M., Gertenbach, M., Holland, R., Peterse, J. L., Rutgers, E. J. T., & Gilhuijs, K. G. A. (2010) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2010.07.025 · Cited by 54
Chong, I. Y.-S., Hawkins, M., Hansen, V. N., Thomas, K., McNair, H. A., O’Neill, B., Aitken, A., & Tait, D. (2011) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2011.04.060 · Cited by 53
Gaertner, F. C., Fürst, S., & Schwaiger, M. (2013) · Cancer Imaging · doi:10.1102/1470-7330.2013.0005 · Cited by 52
Outcomes of Diffusion Tensor Tractography–Integrated Stereotactic Radiosurgery
Koga, T., Maruyama, K., Kamada, K., Ota, T., Shin, M., Itoh, D., Kunii, N., Ino, K., Terahara, A., Aoki, S., et al. (2011) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.11.046 · Cited by 50
Attenuation Correction Synthesis for Hybrid PET-MR Scanners
Burgos, N., Cardoso, M. J., Marc Modat, A., Pedemonte, S., Dickson, J. C., Barnes, A., Duncan, J. S., Atkinson, D., Arridge, S., Hutton, B. F., et al. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-40811-3_19 · Cited by 49
Jolicoeur, M., Racine, M.-L., Trop, I., Hathout, L., Nguyen, D. H. A., Derashodian, T., & David, S. (2011) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2011.08.024 · Cited by 47
A comparison of brachytherapy techniques for partial breast irradiation
Hepel, J. T., & Wazer, D. E. (2011) · Brachytherapy · doi:10.1016/j.brachy.2011.06.001 · Cited by 47
Functional magnetic resonance imaging
Matthews, P. M. (2008) · CRC Press eBooks · doi:10.1201/b15118-65 · Cited by 46
Önal, C., Sönmez, S., Erbay, G., Güler, O. C., & Arslan, G. (2013) · British Journal of Radiology · doi:10.1259/bjr.20130617 · Cited by 42
Magnetic resonance imaging for adaptive cobalt tomotherapy: A proposal
Kron, T., Eyles, D., Schreiner, L. J., & Battista, J. J. (2006) · Journal of Medical Physics · doi:10.4103/0971-6203.29194 · Cited by 34
Maikusa, N., Yamashita, F., Tanaka, K., Abe, O., Kawaguchi, A., Kabasawa, H., Chiba, S., Kasahara, A., Kobayashi, N., Yuasa, T., et al. (2013) · Medical Physics · doi:10.1118/1.4801913 · Cited by 32
Target Identification for Stereotactic Thalamotomy Using Diffusion Tractography
Kincses, Z. T., Szabó, N., Valálik, I., Kopniczky, Z., Dézsi, L., Klivènyi, P., Jenkinson, M., Király, A., Babos, M., Vörös, E., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0029969 · Cited by 32
Riches, S. F., Payne, G. S., deSouza, N. M., Dearnaley, D. P., Morgan, V. A., Morgan, S. C., & Partridge, M. (2014) · British Journal of Radiology · doi:10.1259/bjr.20130813 · Cited by 29
Self-citationAslian, H., Sadeghi, M., Mahdavi, S. R., Mofrad, F. B., Astarakee, M., Khaledi, N., & Fadavi, P. (2013) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2013.04.049 · Cited by 27
CT substitutes derived from MR images reconstructed with parallel imaging
Johansson, A., Garpebring, A., Asklund, T., & Nyholm, T. (2014) · Medical Physics · doi:10.1118/1.4886766 · Cited by 26
Quantification of Antiangiogenic and Antivascular Drug Activity by Kinetic Analysis of DCE-MRI Data
Ferl, G. Z., & Port, R. E. (2012) · Clinical Pharmacology & Therapeutics · doi:10.1038/clpt.2012.63 · Cited by 16
First MRI application of an active breathing coordinator
Kaza, E., Symonds‐Tayler, R., Collins, D. J., McDonald, F., McNair, H. A., Scurr, E. D., Koh, D.-M., & Leach, M. O. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/4/1681 · Cited by 16
Arias‐Mendoza, F., Payne, G. S., Zakian, K. L., Stubbs, M., O’Connor, O. A., Mojahed, H., Smith, M. R., Schwarz, A. J., Shukla‐Dave, A., Howe, F. A., et al. (2013) · Academic Radiology · doi:10.1016/j.acra.2013.04.013 · Cited by 11
Self-citationMagnetic resonance lymphography in gynaecological malignancies
Jahan, N., Narayanan, P., & Rockall, A. (2010) · Cancer Imaging · doi:10.1102/1470-7330.2010.0006 · Cited by 9
Nishiyama, T., Tomita, Y., & Takahashi, K. (2004) · Urology · doi:10.1016/j.urology.2003.11.030 · Cited by 7
Cited by
MR-based synthetic CT generation using a deep convolutional neural network method
Han, X. (2017) · Medical Physics · doi:10.1002/mp.12155 · Cited by 711
Molecularly Imprinted Polymers: Antibody Mimics for Bioimaging and Therapy
Haupt, K., Medina Rangel, P. X., & Bui, B. T. S. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00428 · Cited by 561
A review of multimodal image matching: Methods and applications
Jiang, X., Ma, J., Xiao, G., Shao, Z., & Guo, X. (2021) · Information Fusion · doi:10.1016/j.inffus.2021.02.012 · Cited by 532
Johnstone, E., Wyatt, J. J., Henry, A. M., Short, S. C., Sebag-Montefiore, D., Murray, L., Kelly, C. G., McCallum, H. M., & Speight, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.08.043 · Cited by 317
Survey on deep learning for radiotherapy
Meyer, P., Noblet, V., Mazzara, C., & Lallement, A. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.05.018 · Cited by 302
Metadata
- Authors
- Schmidt, M. A., & Payne, G. S.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2015-10-28
- Volume
- 60
- Issue
- 22
- Pages
- R323-R361
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1859655790
- Cited by
- 357
- References
- 101
- FWCI
- 31.13
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.