Abstract
The use of magnetic resonance imaging (MRI) in radiotherapy (RT) planning is rapidly expanding. We review the wide range of image contrast mechanisms available to MRI and the way they are exploited for RT planning. However a number of challenges are also considered: the requirements that MR images are acquired in the RT treatment position, that they are geometrically accurate, that effects of patient motion during the scan are minimized, that tissue markers are clearly demonstrated, that an estimate of electron density can be obtained. These issues are discussed in detail, prior to the consideration of a number of specific clinical applications. This is followed by a brief discussion on the development of real-time MRI-guided RT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952 · cited 1×
“The recent advent of parallel imaging and sparse sampling techniques has allowed faster data acquisition, and it is now possible to acquire volumetric data with high temporal resolution (Lustig et al 2007, Lustig and Pauly 2010).”
BackgroundPrinciples of Nuclear Magnetic Resonance Microscopy
Callaghan, P. T. (1991) · doi:10.1093/oso/9780198539445.001.0001 · Cited by 3,599
Increase in signal-to-noise ratio of > 10,000 times in liquid-state NMR
Ardenkjær-Larsen, J. H., Fridlund, B., Gram, A., Hansson, G., Hansson, L., Lerche, M. H., Servin, R., Thaning, M., & Golman, K. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1733835100 · Cited by 2,861
ESUR prostate MR guidelines 2012
Barentsz, J. O., Richenberg, J., Clements, R., Choyke, P., Verma, S., Villeirs, G., Rouviere, O., Logager, V., & Fütterer, J. J. (2012) · European Radiology · doi:10.1007/s00330-011-2377-y · Cited by 2,438
Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and Recommendations
Padhani, A. R., Liu, G., Mu-Koh, D., Chenevert, T. L., Thoeny, H. C., Takahara, T., Dzik-Jurasz, A., Ross, B. D., Van Cauteren, M., Collins, D., et al. (2009) · Neoplasia · doi:10.1593/neo.81328 · Cited by 1,989
Tofts, P. S., & Kermode, A. G. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170208 · Cited by 1,456
Seppenwoolde, Y., Shirato, H., Kitamura, K., Shimizu, S., van Herk, M., Lebesque, J. V., & Miyasaka, K. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02803-1 · Cited by 1,379
Metabolic Imaging of Patients with Prostate Cancer Using Hyperpolarized [1- 13 C]Pyruvate
Nelson, S. J., Kurhanewicz, J., Vigneron, D. B., Larson, P. E. Z., Harzstark, A. L., Ferrone, M., van Criekinge, M., Chang, J. W., Bok, R., Park, I., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3006070 · Cited by 1,286
Jovicich, J., Czanner, S., Greve, D., Haley, E., van der Kouwe, A., Gollub, R., Kennedy, D., Schmitt, F., Brown, G., MacFall, J., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.09.046 · Cited by 1,265
Cited by
MR-based synthetic CT generation using a deep convolutional neural network method
Han, X. (2017) · Medical Physics · doi:10.1002/mp.12155 · Cited by 711
Molecularly Imprinted Polymers: Antibody Mimics for Bioimaging and Therapy
Haupt, K., Medina Rangel, P. X., & Bui, B. T. S. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00428 · Cited by 561
A review of multimodal image matching: Methods and applications
Jiang, X., Ma, J., Xiao, G., Shao, Z., & Guo, X. (2021) · Information Fusion · doi:10.1016/j.inffus.2021.02.012 · Cited by 532
Johnstone, E., Wyatt, J. J., Henry, A. M., Short, S. C., Sebag-Montefiore, D., Murray, L., Kelly, C. G., McCallum, H. M., & Speight, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.08.043 · Cited by 317
Survey on deep learning for radiotherapy
Meyer, P., Noblet, V., Mazzara, C., & Lallement, A. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.05.018 · Cited by 302
MRI‐only based synthetic CT generation using dense cycle consistent generative adversarial networks
Lei, Y., Harms, J., Wang, T., Liu, Y., Shu, H., Jani, A. B., Curran, W. J., Mao, H., Liu, T., & Yang, X. (2019) · Medical Physics · doi:10.1002/mp.13617 · Cited by 297
Maspero, M., Savenije, M. H. F., Dinkla, A. M., Seevinck, P. R., Intven, M. P. W., Jurgenliemk-Schulz, I. M., Kerkmeijer, L. G. W., & van den Berg, C. A. T. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aada6d · Cited by 253
MRI-only treatment planning: benefits and challenges
Owrangi, A. M., Greer, P. B., & Glide-Hurst, C. K. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aaaca4 · Cited by 236
The future of image-guided radiotherapy will be MR guided
Pollard, J. M., Wen, Z., Sadagopan, R., Wang, J., & Ibbott, G. S. (2017) · The British Journal of Radiology · doi:10.1259/bjr.20160667 · Cited by 201
“Quality assurance (QA) must be performed to ensure the geometric accuracy of the MRI data set, and MR images lack electron density information that is needed for RT dose calculations.(74) The American Association of Physicists in Medicine’s Task Group 142, lists guidelines for daily tolerances for the coincidence betw…”
BackgroundMethodInfluentialDeep learning based synthetic‐CT generation in radiotherapy and PET: A review
Spadea, M. F., Maspero, M., Zaffino, P., & Seco, J. (2021) · Medical Physics · doi:10.1002/mp.15150 · Cited by 201
Unsupervised Multi-Modal Image Registration via Geometry Preserving Image-to-Image Translation
Arar, M., Ginger, Y., Danon, D., Bermano, A. H., & Cohen-Or, D. (2020) · 2020 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr42600.2020.01342 · Cited by 175
Pathmanathan, A. U., van As, N. J., Kerkmeijer, L. G. W., Christodouleas, J., Lawton, C. A. F., Vesprini, D., van der Heide, U. A., Frank, S. J., Nill, S., Oelfke, U., et al. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.10.020 · Cited by 172
Metadata
- Authors
- Schmidt, M. A., & Payne, G. S.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2015-10-28
- Volume
- 60
- Issue
- 22
- Pages
- R323-R361
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1859655790
- Cited by
- 357
- References
- 101
- FWCI
- 31.13
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.