Motion correction in MRI of the brain
Open accessThe DOI matches its Crossref record; 101 of the 101 references it cites were found in a registry or an index.
Abstract
Subject motion in MRI is a relevant problem in the daily clinical routine as well as in scientific studies. Since the beginning of clinical use of MRI, many research groups have developed methods to suppress or correct motion artefacts. This review focuses on rigid body motion correction of head and brain MRI and its application in diagnosis and research. It explains the sources and types of motion and related artefacts, classifies and describes existing techniques for motion detection, compensation and correction and lists established and experimental approaches. Retrospective motion correction modifies the MR image data during the reconstruction, while prospective motion correction performs an adaptive update of the data acquisition. Differences, benefits and drawbacks of different motion correction methods are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
A global optimisation method for robust affine registration of brain images
Jenkinson, M., & Smith, S. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00036-6 · Cited by 6,872 · cited 2×
“They are using subsets of motion affected and motion free data to estimate the motion with the registration scheme from (Jenkinson and Smith 2001).”
BackgroundMethodAndersson, J. L. R., Skare, S., & Ashburner, J. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00336-7 · Cited by 3,469 · cited 1×
“…mapping have been proposed including dual echo-time field mapping (Reber et al 1998, Hutton et al 2002), reference maps calculated using Fourier methods (Chen and Wyrwicz 1999, 2001), point spread function mapping (Zeng and Constable 2002), and reversed gradient polarities (Andersson et al 2003).”
MethodLeast-squares estimation of transformation parameters between two point patterns
Umeyama, S. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.88573 · Cited by 2,420 · cited 1×
“They estimated object movement from comparison of periodic updates of the marker positions (Umeyama 1991).”
BackgroundHandbook of MRI Pulse Sequences
(2004) · Elsevier eBooks · doi:10.1016/b978-0-12-092861-3.x5000-6 · Cited by 1,610
Correction for geometric distortion in echo planar images from B 0 field variations
Jezzard, P., & Balaban, R. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340111 · Cited by 1,421 · cited 2×
“If known, these static geometric distortions can be considered in the reconstruction using the pixel shift method (Jezzard and Balaban 1995) and can be corrected in the presence of motion as described above.”
BackgroundMethodMotion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging
Pipe, J. G. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<963::aid-mrm17>3.0.co;2-l · Cited by 928 · cited 8×
“After each VD spiral interleave, a phase error is estimated from the lowresolution images allowing estimation of in-plane translational motion similar to PROPELLER.”
BackgroundMethodInfluentialAdaptive technique for high-definition MR imaging of moving structures.
Ehman, R. L., & Felmlee, J. P. (1989) · Radiology · doi:10.1148/radiology.173.1.2781017 · Cited by 801 · cited 4×
“However, it assumes a single moving object within the FoV and it cannot measure rotation as well as translation in z-direction (Fu et al 1995). Hu et al (1994) used a single data point in a gradient echo sequence instead of a full NAV echo to detect signal fluctuations in functional imaging.”
MethodInfluentialMotion artifacts in MRI: A complex problem with many partial solutions
Zaitsev, M., Maclaren, J., & Herbst, M. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24850 · Cited by 774 · cited 1×
“Patient-related artefacts: motion artefacts, susceptibility artefacts; For a better understanding of the effects of motion on MR images, it is helpful to consider the image formation process (for physical artefact description see also (Zaitsev et al 2015)).”
Background
Cited by
Imaging structural and functional brain development in early childhood
Gilmore, J. H., Knickmeyer, R. C., & Gao, W. (2018) · Nature Reviews Neuroscience · doi:10.1038/nrn.2018.1 · Cited by 1,013
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Self-citationon behalf of the MAGNIMS study group, Sastre-Garriga, J., Pareto, D., Battaglini, M., Rocca, M. A., Ciccarelli, O., Enzinger, C., Wuerfel, J., Sormani, M. P., Barkhof, F., et al. (2020) · Nature Reviews Neurology · doi:10.1038/s41582-020-0314-x · Cited by 273
Chen, Z., Pawar, K., Ekanayake, M., Pain, C., Zhong, S., & Egan, G. F. (2022) · Journal of Digital Imaging · doi:10.1007/s10278-022-00721-9 · Cited by 224
“Godenschweger et al. [60] simulated motion for the 2D images using a patch-based CNN approach to remove artefact from each small patch of image and assembled the patches to generate a motion-corrected image.”
MethodEEG-Informed fMRI: A Review of Data Analysis Methods
Abreu, R., Leal, A., & Figueiredo, P. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00029 · Cited by 171
“Although they do not need additional hardware unlike tracker devices and active markers, the use of navigator echoes requires longer acquisition times (a recent review on this topic can be found in Godenschweger et al., 2016).”
BackgroundAutomated reference-free detection of motion artifacts in magnetic resonance images
Küstner, T., Liebgott, A., Mauch, L., Martirosian, P., Bamberg, F., Nikolaou, K., Yang, B., Schick, F., & Gatidis, S. (2018) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-017-0650-z · Cited by 102
Metadata
- Authors
- Godenschweger, F., Kägebein, U., Stucht, D., Yarach, U., Sciarra, A., Yakupov, R., Lüsebrink, F., Schulze, P., & Speck, O.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2016-02-11
- Volume
- 61
- Issue
- 5
- Pages
- R32-R56
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2265592961
- Cited by
- 221
- References
- 101
- FWCI
- 9.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.