Non-invasive estimate of the mechanical properties of peripheral arteries from ultrasonic and photoplethysmographic measurements
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
The non-linear elastic response of arteries implies that their mechanical properties depend strongly on blood pressure. Thus, dynamic measurements of both the diameter and pressure curves over the whole cardiac cycle are necessary to characterise properly the elastic behaviour of an artery. We propose a novel method of estimating these mechanical properties based on the analysis of the arterial diameter against pressure curves derived from ultrasonic and photoplethysmographic measurements. An ultrasonic echo tracking device has been developed that allows continuous recording of the internal diameter of peripheral arteries. It measures the diameter 300 times per second with a resolution of 2.5 microns. This system is linked to a commercially available light-plethysmograph which continuously records the finger arterial pressure (0.25 kPa accuracy). Because of the finite pulse wave velocity, the separation between the diameter and the pressure measurement sites causes a hysteresis to appear in the recorded diameter-pressure curve. Using a model based on haemodynamic considerations, the delay between the diameter variations and the finger arterial pressure is first eliminated. As the pulse wave velocity depends on the pressure, the delay is determined for each pressure value. The relationship between pressure and diameter is then described by a non-linear mathematical expression with three parameters, which best fits the recorded data. The dynamic local behaviour of the vessel is fully characterised by these parameters. Compliance, distensibility and pulse wave velocity can then be calculated at each pressure level. Thus, the mechanical behaviour of peripheral human arteries can now be characterised non-invasively over the pressure range of the whole cardiac cycle. The results obtained in vivo on human radial and brachial arteries show that a thorough analysis of the compliance-pressure curves and their modifications (curving, shift) is needed in order to compare two different vessels in a meaningful way.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The dynamic elastic properties of the arterial wall
Bergel, D. H. (1961) · The Journal of Physiology · doi:10.1113/jphysiol.1961.sp006687 · Cited by 904
Mechanical Properties of Arteries in Vivo
PETERSON, L. H., JENSEN, R. E., & PARNELL, J. (1960) · Circulation Research · doi:10.1161/01.res.8.3.622 · Cited by 679
Stiffness and elastic behavior of human intracranial and extracranial arteries
Hayashi, K., Handa, H., Nagasawa, S., Okumura, A., & Moritake, K. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90191-8 · Cited by 619
Langewouters, G. J., Wesseling, K. H., & Goedhard, W. J. A. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90034-4 · Cited by 544
Assessment of the distensibility of superficial arteries
Hoeks, A. P. G., Brands, P. J., Smeets, F. A. M., & Reneman, R. S. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90139-4 · Cited by 479
IMHOLZ, B. P. M., MONTFRANS, G. A. V., SETTELS, J. J., HOEVEN, G. M. A. V. D., KAREMAKER, J. M., & WIELING, W. (1988) · Cardiovascular Research · doi:10.1093/cvr/22.6.390 · Cited by 275
Effects of peripheral vasoconstriction on the measurement of blood pressure in a finger
WESSELING, K. H., SETTELS, J. J., HOEVEN, G. M. A. V. D., NIJBOER, J. A., BUTIJN, M. W. T., & DORLAS, J. C. (1985) · Cardiovascular Research · doi:10.1093/cvr/19.3.139 · Cited by 164
Length–force and volume–pressure relationships of arteries123
Loon, P. V., Klip, W., & Bradley, E. L. (1977) · Biorheology · doi:10.3233/bir-1977-14405 · Cited by 164
Non-invasive ultrasonic measurement of the elastic properties of the human abdominal aorta
IMURA, T., YAMAMOTO, K., KANAMORI, K., MIKAMI, T., & YASUDA, H. (1986) · Cardiovascular Research · doi:10.1093/cvr/20.3.208 · Cited by 160
A phase-locked echo tracking system for recording arterial diameter changes in vivo.
Hokanson, D. E., Mozersky, D. J., Sumner, D. S., & Strandness, D. E. (1972) · Journal of Applied Physiology · doi:10.1152/jappl.1972.32.5.728 · Cited by 152
INVASIVE V. NON-INVASIVE MEASUREMENT OF ARTERIAL PRESSURE
van Egmond, J., Hasenbos, M. A. W. M., & Crul, J. F. (1985) · British Journal of Anaesthesia · doi:10.1093/bja/57.4.434 · Cited by 129
Stettler, J. C., Niederer, P., & Anliker, M. (1981) · Annals of Biomedical Engineering · doi:10.1007/bf02363533 · Cited by 107
Pressure-diameter relationships of segments of human finger arteries
Langewouters, G. J., Zwart, A., Busse, R., & Wesseling, K. H. (1986) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/7/1/003 · Cited by 91
Arterial vascular compliance response to vasodilators by Fourier and pulse contour analysis.
Finkelstein, S. M., Collins, V. R., & Cohn, J. N. (1988) · Hypertension · doi:10.1161/01.hyp.12.4.380 · Cited by 85
Dorlas, J. C., Nijboer, J. A., Butijn, W. T., van der Hoeven, G. M. A., Settels, J. J., Wesseling, K. H., & Miller, R. D. (1985) · Anesthesiology · doi:10.1097/00000542-198503000-00022 · Cited by 84
A Viscoelastic Model for Use in Predicting Arterial Pulse Waves
Holenstein, R., Niederer, P. F., & Anliker, M. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138229 · Cited by 78
Forearm arterial distensibility in systolic hypertension
Smulyan, H., Vardan, S., Griffiths, A., & Gribbin, B. (1984) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(84)80024-8 · Cited by 69
Noninvasive measurements of nonlinear arterial elasticity
Megerman, J., Hasson, J. E., Warnock, D. F., L'Italien, G. J., & Abbott, W. M. (1986) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1986.250.2.h181 · Cited by 67
Nonlinear wave propagation in viscoelastic tubes: Application to aortic rupture
Kivity, Y., & Collins, R. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90071-2 · Cited by 60
Influence of Flow and Pressure on Wave Propagation in the Canine Aorta
HISLAND, M. B., & ANLIKER, M. (1973) · Circulation Research · doi:10.1161/01.res.32.4.524 · Cited by 48
The mechanical properties of exposed human common carotid arteries in vivo
Busse, R., Bauer, R. D., Schabert, A., Summa, Y., Bumm, P., & Wetterer, E. (1979) · Basic Research in Cardiology · doi:10.1007/bf01907647 · Cited by 47
Large Deformation Analysis of the Arterial Cross Section
SIMON, B. R., KOBAYASHI, A. S., Strandness, D. E., & Wiederhielm, C. A. (1971) · Journal of Basic Engineering · doi:10.1115/1.3425199 · Cited by 40
Pressure-Volume Relation for Cylindrical Tubes with Elastomeric Walls: The Human Aorta
King, A. L. (1946) · Journal of Applied Physics · doi:10.1063/1.1707745 · Cited by 39
Westling, H., JANSSON, L., Jonson, B., & Nilsén, R. (1984) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a061716 · Cited by 38
Methods of cardiac gating applied potential tomography
Eyüboğlu, B. M., & Brown, B. H. (1988) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/9/4a/008 · Cited by 36
Significant parameters in arterial pressure and velocity development
van der Werff, T. J. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90006-2 · Cited by 34
Shimazu, H., Fukuoka, M., Ito, H., & Yamakoshi, K.-I. (1985) · Medical & Biological Engineering & Computing · doi:10.1007/bf02444026 · Cited by 33
Postsurgical Changes in Arterial Compliance
Hasson, J. E. (1984) · Archives of Surgery · doi:10.1001/archsurg.1984.01390190032007 · Cited by 32
Ghista, D. N., Jayaraman, G., & Sandler, H. (1978) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442452 · Cited by 15
A molecular study of the mechanical properties of arterial vessel walls
Niederer, P. F. (1974) · Zeitschrift für angewandte Mathematik und Physik · doi:10.1007/bf01596119 · Cited by 4
Cited by
Expert consensus document on arterial stiffness: methodological issues and clinical applications
Laurent, S., Cockcroft, J., Van Bortel, L., Boutouyrie, P., Giannattasio, C., Hayoz, D., Pannier, B., Vlachopoulos, C., Wilkinson, I., Struijker-Boudier, H., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl254 · Cited by 6,077
“The two first devices were the Wall Track System57 and the NIUS02.”
MethodJoannides, R., Haefeli, W. E., Linder, L., Richard, V., Bakkali, E. H., Thuillez, C., & Lüscher, T. F. (1995) · Circulation · doi:10.1161/01.cir.91.5.1314 · Cited by 1,622
Olufsen, M. S., Peskin, C. S., Kim, W. Y., Pedersen, E. M., Nadim, A., & Larsen, J. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.1326031 · Cited by 862
Clinical applications of arterial stiffness, Task Force III: recommendations for user procedures
Van Bortel, L. M., Duprez, D., Starmans-Kool, M. J., Safar, M. E., Giannattasio, C., Cockcroft, J., Kaiser, D. R., & Thuillez, C. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02326-3 · Cited by 630
Physical Training Improves Endothelial Function in Patients With Chronic Heart Failure
Hornig, B., Maier, V., & Drexler, H. (1996) · Circulation · doi:10.1161/01.cir.93.2.210 · Cited by 627
Metadata
- Authors
- Tardy, Y., Meister, J. J., Perret, F., Brunner, H. R., & Arditi, M.
- Venue
- Clinical Physics and Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 1991-02
- Volume
- 12
- Issue
- 1
- Pages
- 39-54
- ISSN
- 0143-0815 (ISSN-L)
- OpenAlex
- W2017851551
- Cited by
- 270
- References
- 30
- FWCI
- 6.80
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.