Effects of Peripheral Vasoconstriction on the Blood Pressure in the Finger, Measured Continuously by a New Noninvasive Method (The Finapres®)
Open accessThe DOI matches its Crossref record.
Abstract
The authors determined whether vasoconstriction alters the ability of a noninvasive method (Finapres) of continuously measuring arterial blood pressure in the finger to function accurately. They compared the response of the Finapres to blood pressures determined simultaneously by an oscillometric technique (Dinamap) in six anesthetized patients. Vasoconstriction was detected from a photoelectric plethysmogram, which was recorded continuously from an adjacent finger. Vasoconstriction was defined as a decrease in amplitude to less than half of its highest value in one and the same patient. From the 378 paired blood pressure readings obtained in this study, 51% took place in such a vasoconstricted state. The authors found that diastolic and mean blood pressures in the finger were, on the average, 9 mmHg below those in the upper arm and that the systolic pressure was 7 mmHg above that in the upper arm. The authors concluded that the Finapres keeps functioning well during peripheral vasoconstriction and is a recommendable method to monitor arterial blood pressure in the finger.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fifteen years experience with finger arterial pressure monitoring: assessment of the technology
Imholz, B. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00067-4 · Cited by 834
Tardy, Y., Meister, J. J., Perret, F., Brunner, H. R., & Arditi, M. (1991) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/12/1/003 · Cited by 270
Photoplethysmographic derivation of respiratory rate: A review of relevant physiology
Meredith, D. J., Clifton, D., Charlton, P., Brooks, J., Pugh, C. W., & Tarassenko, L. (2012) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2011.638965 · Cited by 226
Nitzan, M., Babchenko, A., Khanokh, B., & Landau, D. (1998) · Physiological Measurement · doi:10.1088/0967-3334/19/1/008 · Cited by 217
Leitch, J. W., Klein, G. J., Yee, R., Leather, R. A., & Kim, Y. H. (1992) · Circulation · doi:10.1161/01.cir.85.3.1064 · Cited by 171
Metadata
- Authors
- Dorlas, J. C., Nijboer, J. A., Butijn, W. T., van der Hoeven, G. M. A., Settels, J. J., Wesseling, K. H., & Miller, R. D.
- Venue
- Anesthesiology
- Published
- 1985-03-01
- Volume
- 62
- Issue
- 3
- Pages
- 342-345
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1999488857
- Cited by
- 84
- References
- 0
- FWCI
- 2.12
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of Peripheral Vasoconstriction on the Blood Pressure in the Finger, Measured Continuously by a New Noninvasive Method (The Finapres®). https://app.cochat.ai/papers/10.1097/00000542-198503000-00022
- The paper
- Dorlas, J. C., Nijboer, J. A., Butijn, W. T., van der Hoeven, G. M. A., Settels, J. J., Wesseling, K. H., & Miller, R. D. (1985). Effects of Peripheral Vasoconstriction on the Blood Pressure in the Finger, Measured Continuously by a New Noninvasive Method (The Finapres®). Anesthesiology. https://doi.org/10.1097/00000542-198503000-00022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.