The DOI matches its Crossref record.
Effects of peripheral vasoconstriction on the measurement of blood pressure in a finger
Abstract
Using noninvasive techniques only, the fall in mean pressure and the pulse amplification between brachial and finger arterial pressure were measured in six anaesthetised female subjects during surgery. Brachial pressure was measured every 2 min with an oscillometric technique. Finger pressure was measured continuously using an arterial volume clamp method. In addition changes in the degree of peripheral vasoconstriction were established on an adjacent finger with a photo reflection plethysmograph. On the average finger mean pressure is 10 mmHg below brachial pressure. The difference tends to decrease with increasing constriction. The change in the difference between full constriction and maximal dilatation is 8 mmHg. The average finger to brachial pulse amplitude ratio changes from 110% at maximal dilatation to 170% at full constriction. Finger systolic pressure overshoot is responsible for the pulse wave amplification. On the average it is + 7 mmHg and ranges between maximal dilatation and full constriction over 26 mmHg. The standard error deviation on the volume clamp method could be established at 5% for mean pressure, about equal to that of the oscillometric technique in the literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pagani, M., Lombardi, F., Guzzetti, S., Rimoldi, O., Furlan, R., Pizzinelli, P., Sandrone, G., Malfatto, G., Dell'Orto, S., & Piccaluga, E. (1986) · Circulation Research · doi:10.1161/01.res.59.2.178 · Cited by 4,130
Parati, G., Casadei, R., Groppelli, A., Di Rienzo, M., & Mancia, G. (1989) · Hypertension · doi:10.1161/01.hyp.13.6.647 · Cited by 899
Hemodynamic fluctuations and baroreflex sensitivity in humans: a beat-to-beat model
deBoer, R. W., Karemaker, J. M., & Strackee, J. (1987) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1987.253.3.h680 · Cited by 851
Fifteen years experience with finger arterial pressure monitoring: assessment of the technology
Imholz, B. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00067-4 · Cited by 834
Tardy, Y., Meister, J. J., Perret, F., Brunner, H. R., & Arditi, M. (1991) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/12/1/003 · Cited by 270
Metadata
- Authors
- WESSELING, K. H., SETTELS, J. J., HOEVEN, G. M. A. V. D., NIJBOER, J. A., BUTIJN, M. W. T., & DORLAS, J. C.
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1985-03-01
- Volume
- 19
- Issue
- 3
- Pages
- 139-145
- ISSN
- 0008-6363 (ISSN-L)
- OpenAlex
- W2032816228
- Cited by
- 164
- References
- 0
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of peripheral vasoconstriction on the measurement of blood pressure in a finger. https://app.cochat.ai/papers/10.1093/cvr/19.3.139
- The paper
- WESSELING, K. H., SETTELS, J. J., HOEVEN, G. M. A. V. D., NIJBOER, J. A., BUTIJN, M. W. T., & DORLAS, J. C. (1985). Effects of peripheral vasoconstriction on the measurement of blood pressure in a finger. Cardiovascular Research. https://doi.org/10.1093/cvr/19.3.139
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.