Numerical methods for volume preserving image registration
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Image registration is one of today's challenging image processing problems, particularly in medical imaging. Since the problem is ill posed, one may like to add additional information about distortions. This applies, for example, to the registration of time series of contrast-enhanced images, where variations of substructures are not related to patient motion but to contrast uptake. Here, one may only be interested in registrations which do not alter the volume of any substructure. In this paper, we discuss image registration techniques with a focus on volume preserving constraints. These constraints can reduce the non-uniqueness of the registration problem significantly. Our implementation is based on a constrained optimization formulation. Upon discretization, we obtain a large, discrete, highly nonlinear optimization problem and the necessary conditions for the solution form a discretized nonlinear partial differential equation. To solve the problem we use a variant of the sequential quadratic programming method. Finally, we present results on synthetic as well as on real-life data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yee, K. (1966) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.1966.1138693 · Cited by 15,008 · cited 2×
“Staggered grids are very common for the stable discretization of fluid flow problems (see, e.g., [14]) where first order dierential constraints are discretized and in electromagnetics (se e.g., [ 35 , 18]) where operators such as curl and divergence are discretized.”
Horn, B. K. P., & Schunck, B. G. (1981) · Artificial Intelligence · doi:10.1016/0004-3702(81)90024-2 · Cited by 10,312
(1999) · Springer Series in Operations Research and Financial Engineering · doi:10.1007/b98874 · Cited by 9,482
Methods of Mathematical Physics
Courant, R., & Hilbert, D. (1989) · Wiley eBooks · doi:10.1002/9783527617210 · Cited by 8,067
Horn, B. K., & Schunck, B. G. (1981) · SPIE Proceedings · doi:10.1117/12.965761 · Cited by 7,394
Mixed and Hybrid Finite Element Methods
(1991) · Springer Series in Computational Mathematics · doi:10.1007/978-1-4612-3172-1 · Cited by 6,390 · cited 1×
“It is well known that such a discretization should fulfill the LBB conditions [2].”
Principal warps: thin-plate splines and the decomposition of deformations
Bookstein, F. L. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.24792 · Cited by 4,913
The Finite Element Method in Electromagnetics
Jin, J. (1993) · Cited by 3,869
Alignment by Maximization of Mutual Information
Viola, P., & Wells III, W. M. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007958904918 · Cited by 2,610
Computational Techniques for Fluid Dynamics 1
Fletcher, C. A. J. (1998) · Springer eBooks · doi:10.1007/978-3-642-58229-5 · Cited by 1,723
Solution of Sparse Indefinite Systems of Linear Equations
Paige, C. C., & Saunders, M. A. (1975) · SIAM Journal on Numerical Analysis · doi:10.1137/0712047 · Cited by 1,620 · cited 1×
“Here we have used minres [26] with a preconditioning as proposed in [29].”
Numerical Methods for Image Registration
Modersitzki, J. (2003) · doi:10.1093/acprof:oso/9780198528418.001.0001 · Cited by 923 · cited 1×
“, [20, 24].”
Self-citationAugmented Lagrangian Methods: Applications to the Numerical Solution of Boundary-Value Problems
(1983) · Studies in Mathematics and Its Applications · doi:10.1016/s0168-2024(08)x7003-1 · Cited by 760
Methods of Mathematical Physics: Partial Differential Equations
Courant, R., & Hilbert, D. (1989) · doi:10.1002/9783527617234 · Cited by 735
Christensen, G. E., & Johnson, H. J. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.932742 · Cited by 636 · cited 1×
“Constraints are sometimes treated by penalization [7, 32], which in a sense is similar to the regularized approach.”
On pressure boundary conditions for the incompressible Navier‐Stokes equations
Gresho, P. M., & Sani, R. L. (1987) · International Journal for Numerical Methods in Fluids · doi:10.1002/fld.1650071008 · Cited by 605
Rohlfing, T., Maurer, C. R., Bluemke, D. A., & Jacobs, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.814791 · Cited by 445
Variational Methods for Multimodal Image Matching
Hermosillo, G., Chefd'Hotel, C., & Faugeras, O. (2002) · International Journal of Computer Vision · doi:10.1023/a:1020830525823 · Cited by 388
Optimal registration of deformed images
Broit, C. (1981) · Scholarly Commons (University of Pennsylvania) · Cited by 329
Curvature Based Image Registration
Fischer, B., & Modersitzki, J. (2003) · Journal of Mathematical Imaging and Vision · doi:10.1023/a:1021897212261 · Cited by 289 · cited 2×
“This includes well-known choices, such as, for example, the elastic [6, 8, 11, 18], the diffusion [12, 25], and the biharmonic [3, 14] regularizer.”
Self-citationHandbook of Medical Imaging, Volume 2. Medical Image Processing and Analysis
(2000) · SPIE eBooks · doi:10.1117/3.831079 · Cited by 278
Schnabel, J. A., Tanner, C., Castellano-Smith, A. D., Degenhard, A., Leach, M. O., Hose, D. R., Hill, D. L. G., & Hawkes, D. J. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.808367 · Cited by 255
Fast Finite Volume Simulation of 3D Electromagnetic Problems with Highly Discontinuous Coefficients
Haber, E., & Ascher, U. M. (2001) · SIAM Journal on Scientific Computing · doi:10.1137/s1064827599360741 · Cited by 167 · cited 1×
“, [20, 38]) where operators such as curl and divergence are discretized.”
Self-citationA Variational Approach to Nonrigid Morphological Image Registration
Droske, M., & Rumpf, M. (2004) · SIAM Journal on Applied Mathematics · doi:10.1137/s0036139902419528 · Cited by 154
Fischer, B., & Jan Modersitzki, C. (2002) · Contemporary mathematics - American Mathematical Society · doi:10.1090/conm/313/05372 · Cited by 121
Fast inversion of matrices arising in image processing
Fischer, B., & Jan Modersitzki, C. (1999) · Numerical Algorithms · doi:10.1023/a:1019194421221 · Cited by 102 · cited 2×
“This includes well-known choices, such as, for example, the elastic [6, 8, 11, 18], the diffusion [12, 25], and the biharmonic [3, 14] regularizer.”
Iterative Multigrid Regularization Techniques for Image Matching
Henn, S., & Witsch, K. (2001) · SIAM Journal on Scientific Computing · doi:10.1137/s106482750037161x · Cited by 65 · cited 1×
“Even with this additional constraints, however, image registration is an illposed problem, cf., e.g., [20] [24].”
Advances in elastic matching theory and its implementation
Gee, J. C., Haynor, D. R., Briquer, L. L., & Bajcsy, R. (1997) · Lecture notes in computer science · doi:10.1007/bfb0029225 · Cited by 39 · cited 1×
“This includes well-known choices, like, for example, the elastic [4, 6, 15, 9], the diffusion [23, 10], and the biharmonic [1, 12] regularizer.”
Area-Preserving Mappings for the Visualization of Medical Structures
Zhu, L., Haker, S. J., & Tannenbaum, A. (2003) · Lecture notes in computer science · doi:10.1007/978-3-540-39903-2_35 · Cited by 30 · cited 1×
“The VP approach is also connected to the so-called mass preserving (MP) registration which is related to the Monge-Kantorovich transport problem; see [19, 36 ].”
Cited by
Numerical solution of saddle point problems
Benzi, M., Golub, G. H., & Liesen, J. (2005) · Acta Numerica · doi:10.1017/s0962492904000212 · Cited by 2,300
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“Modersitzki introduced a third term in an objective function comprising a matching and a regularization term.”
BackgroundMethodInfluentialHandbook of Mathematical Methods in Imaging
(2011) · Springer eBooks · doi:10.1007/978-0-387-92920-0 · Cited by 334
Image-based large-eddy simulation in a realistic left heart
Chnafa, C., Mendez, S., & Nicoud, F. (2014) · Computers & Fluids · doi:10.1016/j.compfluid.2014.01.030 · Cited by 193
Ill-posed medicine—an introduction to image registration
Fischer, B., & Modersitzki, J. (2008) · Inverse Problems · doi:10.1088/0266-5611/24/3/034008 · Cited by 185
“Rather than interpolating the measurements that are usually corrupted by noise, a smoother approximation is used [41, 42].”
BackgroundSelf-citation
Metadata
- Authors
- Haber, E., & Modersitzki, J.
- Venue
- Inverse Problems
- Publisher
- IOP Publishing
- Published
- 2004-08-07
- Volume
- 20
- Issue
- 5
- Pages
- 1621-1638
- ISSN
- 0266-5611 (ISSN-L)
- 1361-6420
- OpenAlex
- W2123723083
- Cited by
- 178
- References
- 29
- FWCI
- 7.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.